Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"running bond"”.

  1. The influence of vertical reinforcement and lateral confinement on the axial capacity of masonry block walls

    … grouted concrete masonry walls built in running bond. In order to better understand the structural behaviour of both confined and unconfined concrete masonry, it is important to have some knowledge of the load-displacement behaviour, stress-strain behaviour and failure modes of the …

    sask Repository record for The influence of vertical reinforcement and lateral confinement on the axial capacity of masonry block walls (opens in a new tab)

  2. Compressive strength and constitutive behavior of clay tile prisms

    … were 13" thick. The prisms were constructed with running bond, a full bed joint, and face shell bedding for the head joint. The 8" prisms were tested at various angles to bed joint. The 13" prisms were tested with the bed joint either horizontal or vertical. The prism failure pattern depended on …

    ut-knoxville Repository record for Compressive strength and constitutive behavior of clay tile prisms (opens in a new tab)

  3. Realistic Wind Loads on Reinforced Masonry Walls

    … mm hollow concrete masonry blocks arranged in a running bond pattern. The dynamic load was generated using a 4th order autoregressive function to produce a series of realistic wind load time histories for varying wind intensities. The dynamic loads and the quasi-static loads were applied using a …

    sask Repository record for Realistic Wind Loads on Reinforced Masonry Walls (opens in a new tab)

  4. Structural Behaviour of Plastered Straw Bale Panels Under Non-Uniform Loading

    … durable. Rectangular straw bales stacked in a running bond and plastered on the interior and exterior faces have adequate strength to resist typical loads found in two-storey structures. The structural behaviour of a load-bearing plastered straw bale wall subject to uniform loading is well …

    queens Repository record for Structural Behaviour of Plastered Straw Bale Panels Under Non-Uniform Loading (opens in a new tab)

  5. Out-of-plane behaviour of concrete block walls with unbonded reinforcement

    … block walls reinforced with non-prestressed, unbonded reinforcement. This study included a total of 21 walls that were built to identify potential alternatives to unreinforced and conventionally grouted and reinforced walls. The strength and serviceability of these walls was evaluated. All walls …

    sask Repository record for Out-of-plane behaviour of concrete block walls with unbonded reinforcement (opens in a new tab)

  6. To achieve with the least possible means a home of one’s own: Designing a wood masonry building using offcuts from the sawmill industry

    … plank offcuts which were laid like bricks in a running bond. Rather than merely trying to revive this forgotten building technique, it is examined from a contemporary perspective, by studying flows of byproducts from today’s timber industry, and relating the design work to architects who have …

    chalmers Repository record for To achieve with the least possible means a home of one’s own: Designing a wood masonry building using offcuts from the sawmill industry (opens in a new tab)

  7. Impact of Unit Web Height on the Structural Performance of Concrete Masonry Prisms

    … failure modes of prisms. Prisms constructed in running bond with face-shell mortar bedding were constructed and the following parameters were investigated: CMU size, web height, and the use of grout. A total of 18 unique prism configurations with 7 replicates of each resulted in a total of 126 …

    sask Repository record for Impact of Unit Web Height on the Structural Performance of Concrete Masonry Prisms (opens in a new tab)

  8. The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens

    … be tested in the wall splice specimens such that bond failure of the reinforcement occurred. The double pullout specimens were tested in direct tension with six replicates per arrangement. Three values of lap splice length: 150, 200, and 250 mm, were selected from the testing of the double pullout …

    sask Repository record for The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens (opens in a new tab)

  9. Μηχανική προσομοίωση κατασκευών από δομικούς λίθους με χρήση διακριτών στοιχείων και μικρομορφικής θεωρίας συνεχούς μέσου

    … be reproduced, a special case of which is the running bond masonry pattern. In the general case, the discrete system is described by an anisotropic micromorphic continuum of second order that covers both the dynamic and the static regime. The dispersion curves of the discrete system are …

    greece Repository record for Μηχανική προσομοίωση κατασκευών από δομικούς λίθους με χρήση διακριτών στοιχείων και μικρομορφικής θεωρίας συνεχούς μέσου (opens in a new tab)

  10. Dlážděné vozovky a problematika jejich poruch

    Cílem bakalářské práce je zpracovat základní charakteristiky dlážděných vozovek. Vyjmenovat jejich výhody a nevýhody a na konkrétních příkladech poruch těchto vozovek pak navrhnout jejich opravy.