Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 18 of 18 for “"sTGC"”.

  1. Results of the 2018 ATLAS sTGC test beam and internal strip alignment of sTGC detectors

    … technologies - small-strip Thin Gap Chambers (sTGCs) and Micromegas. To characterize the sTGCs, a series of test beams were conducted on a production sTGC module at the H8 beamline of CERN’s Super Proton Synchrotron. The setup and results of the test beams are presented, and it has been found …

    uvic Repository record for Results of the 2018 ATLAS sTGC test beam and internal strip alignment of sTGC detectors (opens in a new tab)

  2. ATLAS New Small Wheel sTGC Pad Efficiency and Signal Strength

    … MicroMegas and small-Strip Thin Gap Chambers (sTGC). The detector layers of the sTGC consist of wires centred between two cathode planes. One cathode plane is segmented into thin strips of constant width and the other into larger pads with variable sizes. From preliminary stand-alone tests and …

    uvic Repository record for ATLAS New Small Wheel sTGC Pad Efficiency and Signal Strength (opens in a new tab)

  3. Simulation of Gas Detectors Using Ramo's Theorem

    … on the gaseous small-strip Thin Gap Chamber (sTGC) multiwire proportional chamber (MWPC) technology. The principle of signal formation is based on the induction of charge on detector elements due to the motion of ionization clusters within the MWPC. A method to determine this induced charge …

    carleton Repository record for Simulation of Gas Detectors Using Ramo's Theorem (opens in a new tab)

  4. Research and development of the trigger system for the New Small Wheel upgrade of the ATLAS experiment at CERN and performance evaluation of the sTGC detector: study for the precise determination of the Z-boson mass.

    … emphasis on the small-strip Thin Gap Chamber (sTGC) trigger system. An extensive description of the rationale behind the NSW upgrade is provided, along with the results from various tests designed to verify the proper operation of all trigger electronics and ensure accurate data transmission …

    greece Repository record for Research and development of the trigger system for the New Small Wheel upgrade of the ATLAS experiment at CERN and performance evaluation of the sTGC detector: study for the precise determination of the Z-boson mass. (opens in a new tab)

  5. Small-strip thin gap chambers for the New Small Wheel Upgrade and search for dark matter production in association with a Z boson with the ATLAS detector

    … (MM) and Small-strip Thin Gap Chambers (sTGC). The thesis navigates through the sTGC operational principles, assembly, testing, and integration, and presents recent results achieved during the current data taking period. Additionally, this work delves into the identification of weakly …

    freiburg-diss Repository record for Small-strip thin gap chambers for the New Small Wheel Upgrade and search for dark matter production in association with a Z boson with the ATLAS detector (opens in a new tab)

  6. Cosmic test stand studies with a small-strip thin gap chamber of the ATLAS New Small Wheel (NSW) upgrade and measurement of the tt̅H(H→bb̅) process at 13 TeV with the ATLAS detector

    … of the NSW, the small-strip Thin Gap Chambers (sTGCs), was studied. They are operated with a high voltage (HV) of 2800 V and an operational gas mixture of CO 2 :C 5 H 12 at a ratio of 55%:45%. A dedicated cosmic muon test stand was constructed with a small sTGC to study the response of the …

    freiburg-diss Repository record for Cosmic test stand studies with a small-strip thin gap chamber of the ATLAS New Small Wheel (NSW) upgrade and measurement of the tt̅H(H→bb̅) process at 13 TeV with the ATLAS detector (opens in a new tab)

  7. Calibration of the readout electronics for the ATLAS NSW project and position resolution of large-scale micromegas detectors

    … Micromegas und small-strip Thin Gap Chambers (sTGC). Diese Detektoren werden mit spezialgefertigten Front-End Boards ausgelesen und haben einen gemeinsamen Auslesechip — den VMM. Dieser ist ein strahlungsharter ASIC mit 64 Auslesekanälen, und er ist in der Lage analoge Signale in MHz Rate zu …

    freiburg-diss Repository record for Calibration of the readout electronics for the ATLAS NSW project and position resolution of large-scale micromegas detectors (opens in a new tab)

  8. Home procedura SCARA robotu

    … první a druhé osy, které jsou řešeny pomocí STGC absolutních snímačů. Další dvě osy jsou řešeny koncovými snímači. Bylo nutné provést úpravu kabeláže a doplnit vstupní kartu řídícímu systému. Nakonec je implementován funkční blok Homing, který zajistí zjištění pózy manipulátoru po spuštění.

    brno-tech Repository record for Home procedura SCARA robotu (opens in a new tab)

  9. Searches for Supersymmetry in events with one-lepton, jets and missing transverse momentum with the ATLAS detector

    … ATLAS detector. Small-strip Thin Gap Chambers (sTGC) are one of the two detector technologies that will be used in the NSW, and are studied under prolonged radiation in preparation for their installation. A prototype sTGC detector is irradiated with a Strontium-90 source of intensity 10mCi. No …

    ubc Repository record for Searches for Supersymmetry in events with one-lepton, jets and missing transverse momentum with the ATLAS detector (opens in a new tab) Download PDF for Searches for Supersymmetry in events with one-lepton, jets and missing transverse momentum with the ATLAS detector (opens in a new tab)

  10. A precision measurement of fiducial and differential cross sections of ww production with the atlas detector at sqrt(s)=13 tev

    … facility to test small-strip Thin Gap Chambers (sTGC), one of the main technologies of the NSW, has been commissioned in Freiburg. Design, installation, and validation of the gas and high-voltage systems necessary for operating a sTGC prototype under nominal conditions of LHC data-taking are …

    freiburg-diss Repository record for A precision measurement of fiducial and differential cross sections of ww production with the atlas detector at sqrt(s)=13 tev (opens in a new tab)

  11. Development of the detector control system for the muon spectrometer of the ATLAS experiment and the Z boson mass measurement

    … components, including the MDT, Micromegas, and sTGC technologies. In parallel, the thesis focuses on the precision measurement of the Z boson mass using reconstructed Z → μ⁺μ⁻ events. A dedicated data analysis pipeline was developed using Histmaker and Monte Carlo simulations, with careful …

    greece Repository record for Development of the detector control system for the muon spectrometer of the ATLAS experiment and the Z boson mass measurement (opens in a new tab)

  12. Research and development of Micromegas detectors for New Physics searches

    … design comprises small-strip Thin Gap Chambers (sTGC) and resistive-strip Micromegas (MM). The sTGC technology will provide triggering information mainly, while the MM will contribute to the tracking reconstruction. A combination of these technologies will reduce the false trigger information. …

    greece Repository record for Research and development of Micromegas detectors for New Physics searches (opens in a new tab)

  13. Search for new high-mass phenomena in events with two muons using the ATLAS detector at the Large Hadron Collider

    … in the NSW is small-strip Thin Gap Chambers (sTGCs). Results of various test beam campaigns carried out at Fermilab and at CERN, aimed at characterizing sTGCs, are presented. Position resolution measurements of less than 50μm are obtained. Measurements using the latest electronics readout …

    ubc Repository record for Search for new high-mass phenomena in events with two muons using the ATLAS detector at the Large Hadron Collider (opens in a new tab) Download PDF for Search for new high-mass phenomena in events with two muons using the ATLAS detector at the Large Hadron Collider (opens in a new tab)

  14. Research and development of the electronics and data acquisition system for the new small wheel upgrade of the ATLAS detector at CERN and performance evaluation of the micromegas chamber

    … (MM) and the small-strip Thin Gap Chambers (sTGC). Designed to cope with the increased background rate of future run conditions, the NSW will provide muon precision tracking data to ATLAS, and also contribute to its triggering scheme. In order to support the newly-installed detector media, a …

    greece Repository record for Research and development of the electronics and data acquisition system for the new small wheel upgrade of the ATLAS detector at CERN and performance evaluation of the micromegas chamber (opens in a new tab)

  15. Search for supersymmetry through the 3-lepton and large missing transverse momentum process with the ATLAS detector at CERN

    … ASIC prototype (VMM1)of the MicroMEGAS and sTGC detectors, under harsh radiation environments, such asthose expected in ATLAS during Run III. For this purpose, two VMM1s were exposedin a neutron irradiation environment using the TANDEM Van Der Graa acceleratorat NSCR Demokritos, Athens, …

    greece Repository record for Search for supersymmetry through the 3-lepton and large missing transverse momentum process with the ATLAS detector at CERN (opens in a new tab)

  16. Design and development of the Level-1 Data Driver Card (L1DDC) for the New Small Wheel upgrade of the ATLAS experiment at CERN

    … the Micromegas and about 332 thousand for the sTGC) and in order to survive in such a harsh environment new electronics must be fabricated and installed. In addition, correction mechanisms for Single Event Upsets (this is a change of state caused by a high-energy particle strike to a …

    greece Repository record for Design and development of the Level-1 Data Driver Card (L1DDC) for the New Small Wheel upgrade of the ATLAS experiment at CERN (opens in a new tab)

  17. Μελέτη του ανιχνευτή Micromegas για την αναβάθμιση του New Small Wheel του πειράματος ATLAS

    … the SW with a New SW (NSW) system, that combines sTGC and resistive MM detectors maintaining in such way the excellent performance of the muon system beyond Run-2.The NSW requires that both technologies will provide level-1 trigger and pattern recognition performance of the reconstruction of track …

    greece Repository record for Μελέτη του ανιχνευτή Micromegas για την αναβάθμιση του New Small Wheel του πειράματος ATLAS (opens in a new tab)