  1. Voltage Sags Indices and Statistics

    … of the power supply, as far as voltage sags are concerned. Indices can be defined for individual events, for individual sites, and for a whole system. A standard method for single-event methods is part of IEC standard 61000-4-30. This thesis emphasizes the importance of voltage sag …

    chalmers Repository record for Voltage Sags Indices and Statistics (opens in a new tab)

  2. Voltage sags in power distribution networks

    Voltage sags have become increasingly important when considering the various power quality issues that cause inconvenience to customers. For some customers voltage sags cause especially high costs. Thus, power distribution companies should understand the voltage sags experienced in their networks …

    aalto Repository record for Voltage sags in power distribution networks (opens in a new tab)

  3. Mitigating voltage sags by optimal placement of series compensation devices using genetic algorithm

    Central mitigation does not necessarily provide the most economical solution to voltage-sag problems. Distributed mitigation with strategically placed compensation devices should provide a better alternative. Placement studies of this nature usually involve extensive evaluations of candidate …

    nus Repository record for Mitigating voltage sags by optimal placement of series compensation devices using genetic algorithm (opens in a new tab) Download file for Mitigating voltage sags by optimal placement of series compensation devices using genetic algorithm (opens in a new tab)

  4. Biochemical and Immunological Mechanisms Underlying Differential Interaction of Superantigens with Host Immunogenetic Factors in Streptococcal Sepsis

    … triggered by streptococcal superantigens (Strep SAgs). SAgs interact simultaneously with HLA class II molecules on antigen presenting cells (APC) and with the T cell receptor beta chain variable elements (TCR V) and cause excessive stimulation of both cell types and massive release of …

    tenn-hsc Repository record for Biochemical and Immunological Mechanisms Underlying Differential Interaction of Superantigens with Host Immunogenetic Factors in Streptococcal Sepsis (opens in a new tab)

  5. Engineering the T Cell Receptor to Protect Host Cells in Superantigen-Induced Septic Shock

    Superantigens (SAgs) are potent pathogenic agents. Produced by bacteria and viruses, these proteins target a subset of white blood cells, namely T cells, which are responsible for the cell-mediated responses of the immune system. SAgs stimulate T cell populations by crosslinking a T cell receptor …

    uiuc Repository record for Engineering the T Cell Receptor to Protect Host Cells in Superantigen-Induced Septic Shock (opens in a new tab)

  6. Afundamentos de tensão em consumidores industriais : uma análise baseada no fator de impacto e na severidade dos eventos considerando os efeitos de faltas elétricas em sistemas de potência

    … Regulation, within the scope of voltage sags. For such comparison, a case study of monitoring is performed on an industrial consumer sensitive to the disturbance during 24 months. Additionally, since the main causes of the voltage sags are the electrical faults of the system to which the …

    brazil-ufrgs Repository record for Afundamentos de tensão em consumidores industriais : uma análise baseada no fator de impacto e na severidade dos eventos considerando os efeitos de faltas elétricas em sistemas de potência (opens in a new tab)

  7. Biological and Transcriptomic Comparison of Two Immunologically Distinct Strains of Eimeria maxima (GS and M6) and Characterization of Their Glycophosphatidylinositol (GPI) Anchored Surface Antigen Expression

    … processes. GPI anchored surface antigens (SAgs) identified in GS (18 SAgs) and M6 (18 SAgs) belonged to four major multi copy gene families and 2 single copy loci. Relative expression of SAgs expressed by both strains was generally similar; however, 3 GPI-anchored SAgs were uniquely …

    guelph Repository record for Biological and Transcriptomic Comparison of Two Immunologically Distinct Strains of Eimeria maxima (GS and M6) and Characterization of Their Glycophosphatidylinositol (GPI) Anchored Surface Antigen Expression (opens in a new tab)

  8. Using PMU and PQ monitor for voltage sag extended-characterization

    … drive systems, which trip due to voltage sags. Voltage sag (dip) is one of the most severe power quality problems. The root cause of voltage sag is a short circuit in the power system, e.g., due to lightning. The consequence of voltage sag may be that expensive power electronic devices are …

    chalmers Repository record for Using PMU and PQ monitor for voltage sag extended-characterization (opens in a new tab)

  9. Development and Validation of the Statistics Assessment of Graduate Students

    … the Statistics Assessment of Graduate Students (SAGS) instrument, and established its preliminary item characteristics, reliability, and validity evidence. Even though there are limited number of assessments available for measuring different aspects of statistical cognition, these previously …

    utk-theses Repository record for Development and Validation of the Statistics Assessment of Graduate Students (opens in a new tab)

  10. Αυτοαξιολόγηση του μαθητή και βελτίωση της ποιότητας της εκπαιδευτικής διαδικασίας στην πρωτοβάθμια εκπαίδευση

    … of Self-Assessment with Goal Setting (SAGS), which was implemented with the educational method of “self-directed learning” (SDL), in improving the quality of the educational process in the context of language teaching to sixth-grade students in primary school. Specifically, the research …

    greece Repository record for Αυτοαξιολόγηση του μαθητή και βελτίωση της ποιότητας της εκπαιδευτικής διαδικασίας στην πρωτοβάθμια εκπαίδευση (opens in a new tab)

  11. Precise correlation and metagenomic binning uncovers fine microbial community structure

    … combined use of single-cell amplifed genomes (SAGs) and metagenomes to more precisely construct population genome bins and evaluates the use of covariance matrix regularization methods to identify putative metabolic interdependencies at the population and community levels of organization. …

    ubc Repository record for Precise correlation and metagenomic binning uncovers fine microbial community structure (opens in a new tab) Download PDF for Precise correlation and metagenomic binning uncovers fine microbial community structure (opens in a new tab)

  12. Modeling of the dynamic voltage restorer in EMTP

    … systems to protect consumers from sudden voltage sags and swells in the grid voltage. This thesis presents a comprehensive model of a DVR using the EMTP simulation software. The model demonstrates significant capabilities in mitigating voltage quality issues, which are prevalent in modern …

    texas Repository record for Modeling of the dynamic voltage restorer in EMTP (opens in a new tab)

  13. ASSESSMENT AND ALLEVIATION OF VOLTAGE SAG-INDUCED ECONOMIC LOSSES IN MODERN INDUSTRIAL DISTRIBUTION SYSTEM

    … PV and VFD could be used to ride through voltage sags and prevent costly load interruption. Hence, this thesis first proposes a method to assess annual economic loss for an industrial network consisting of PV and dynamic loads due to probable voltage sag events. Secondly, the proposed method is …

    nus Repository record for ASSESSMENT AND ALLEVIATION OF VOLTAGE SAG-INDUCED ECONOMIC LOSSES IN MODERN INDUSTRIAL DISTRIBUTION SYSTEM (opens in a new tab) Download file for ASSESSMENT AND ALLEVIATION OF VOLTAGE SAG-INDUCED ECONOMIC LOSSES IN MODERN INDUSTRIAL DISTRIBUTION SYSTEM (opens in a new tab)

  14. Staphylococcal toxic shock syndrome Toxin-1 interactions with human vaginal epithelial cells and novel therapeutics.

    … of virulence factors, including superantigens (SAgs). SAgs are exotoxins that enhance the ability of S. aureus to cause infection by dysregulation of the host’s immune system. Numerous Staphylococcal SAgs have been identified including the staphylococcal enterotoxins (SEA- SEU) and Toxic Shock …

    umn Repository record for Staphylococcal toxic shock syndrome Toxin-1 interactions with human vaginal epithelial cells and novel therapeutics. (opens in a new tab)

  15. Topologia de gerador de distúrbios elétricos baseada em conversores de potência

    Electrical disturbances such as voltage sags, interruptions and voltage unbalances might cause serious problems for the end-user and for the companies of generation and transmission of energy. Few years ago, those companies have been using methods and equipments of protection to avoid the …

    brazil-ufrn Repository record for Topologia de gerador de distúrbios elétricos baseada em conversores de potência (opens in a new tab)

  16. Optimal placement of dynamic voltage restorers and static synchronous compensators for enhancing power quality

    … operation. Among various disturbances, voltage sags pose serious risks to industrial processes, often resulting in equipment malfunction or production losses. This study investigates dynamic voltage restorers (DVRs) and static synchronous compensators (STATCOMs) as PQ issue mitigation devices …

    texas Repository record for Optimal placement of dynamic voltage restorers and static synchronous compensators for enhancing power quality (opens in a new tab)

  17. Voltage sag source location in power systems

    … latter’s critical induction motors to voltage sags. It is shown that the sensitive load at Indeni is vulnerable to voltage sags arising from faults in both the CEC and Zesco networks, the two utilities that handle power before it gets to the customer. Further laboratory measurements were done …

    chalmers Repository record for Voltage sag source location in power systems (opens in a new tab)

  18. Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível

    … to electrical disturbances, especially voltage sags since the stator is directly connected to the grid. This feature highlights a fundamental challenge which is to provide fault support. Given this problem’s relevance, this thesis proposes improving DFIG supportability to a voltage sag in the …

    brazil-ufrn Repository record for Contribuição ao melhoramento da operação durante afundamentos de tensão de geradores de indução duplamente alimentados baseados em conversores modulares multinível (opens in a new tab)

  19. Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage

    … reactive power injection during voltage sags and power quality. From the GCPPP side, the main reasons for inverter disconnection are: loss of synchronization, excessive ac currents, excessive dc voltage, and voltage rise in non-faulty phases under unbalanced voltage sags due to the …

    unsw Repository record for Modelling, Control and Performance of Large-Scale Grid-Connected Solar Photovoltaic Power Plants Under Static and Dynamic Conditions Considering No Energy Storage (opens in a new tab)