The effect of sample pre-treatment and speciation of potentially toxic elements in freshwater sediments impacted by historical metal mining
… River Derwent, UK. In parallel, the influence of sample pretreatment on the operational speciation (fractionation) of PTE in sediment with different matrix characteristics was investigated. Freeze, air, and oven drying separately caused less than 9 % changes in PTE fractionation relative to …
-
Laser desorption - laser photoionization ion trap mass spectrometry for the direct analysis of solid samples
… For calibration, a new type of solid sample preparation method involving activated charcoal as the solid substrate was used. It was found that both the IR and UV intensity, and the delay between them, play an important role in both the magnitude and type of signals observed. A method …
-
An investigation of some chromatographic and electrophoretic seperations for industrial and clinical applications
… and can be ideal methods due to low sample and material consumption, reduced analysis times and increased separation efficiencies. A HPLC method was developed and successfully applied to the analysis of the photoinitiator, bis(2,4,6-trimethylbenzoyl)phenyl-phosphine oxide. A …
-
Detecting trace pollutants used on kiwifruit orchards : a thesis presented in partial fulfilment of the requirements of the degree of Master of Philosophy in Chemistry at Massey University, Manawatu, New Zealand
… often requiring sophisticated machinery and sample pre-treatment to detect them at very low levels. There are new techniques being created, but a significant portion of these are expensive, complicated, or are sensitive to interferents. Most techniques use some form of chromatography, but …
-
Determination of hydrogen peroxide using immobilized chemiluminescence reagents and flow injection analysis
… (detection limit = 25 $\mu$M). The problem presented by real samples was solved using a sample pre-treatment technique.
-
Mikroekstrakcija iš viršerdvės vandens lašu – kapiliarinė elektroforezė lakių neorganinių junginių nustatymui sudėtingose matricose /
The objective of the present work was systematic investigation of water-based headspace single-drop microextraction (SDME) technique, its conjunction with capillary electrophoresis, and application for the analysis of volatile inorganic compounds (cyanide and ammonium) in biomedical and …
-
Water-based headspace single-drop microextraction and capillary electrophoresis for the determination of volatile inorganic compounds in complex matrices /
The objective of the present work was systematic investigation of water-based headspace single-drop microextraction (SDME) technique, its conjunction with capillary electrophoresis, and application for the analysis of volatile inorganic compounds (cyanide and ammonium) in biomedical and …
-
An integrated system for large volume sample processing at the point of care
… diagnostic devices is the ability to perform sample preparation at the POC. Many sensitive systems have been developed, but few have successfully translated out of the laboratory and into clinical use, often due to the lack of testing and compatibility with realistic samples. Therefore, …
-
Development of enzyme-based sensor arrays
… multiple components in complex mixtures can present significant analytical challenges. Characterization of such samples typically requires sample “pre-treatment” steps. Separations, for example, commonly are used to isolate analytes spatially before being determined sequentially. This …
-
The Fermentation of Cheese Whey by Lactobacilius helvecticus
… by Lactobacillus helveticus was studied. Precipitate formation during autoclaving of whey permeate was examined. Precipitation was found to be pH and temperature dependent. Qualitative analysis suggested that the precipitate was a calcium-phosphate complex. Solubilisation was achieved both …
-
Biosensors for fertility and pregnancy in cattle : a thesis presented in partial fulfilment of the requirements for the degree of Doctor of Philosophy in Chemistry at Massey University, Palmerston North, New Zealand
… progesterone sensing in bovine serum and milk samples. P4-PEG-OVA was synthesised, characterised and used for P4 detection. The P4-PEG-OVA sensor surface showed an improvement in surface response compared with two shorter ligand 4TP-P4-OVA and 4TPH-P4-OVA in SPR studies. An analysis method has …
-
Comparison of standard operating procedures used for the detection of opioids in blood
… sensitive, and selective. The application of sample pre-treatment and solid-phase extraction are common to purify and concentrate the target analytes before analyzing with liquid chromatography-tandem mass spectrometry. The purpose of this study was to compare the performance of two standard …
-
Diffusing wave spectroscopy applied to material analysis and process control
… sensor, capable of near real-time feedback. No sample pre-treatment was required and measurement was via a noninvasive, flexible, dip in probe. <br></br><br></br>DWS relies on the concept of the diffusive migration of light, as opposed to the ballistic scatter model used in conventional dynamic …
-
Development of Simplified Analytical methods for In-situ Detection of Ammonia and Urea in Aqueous Solutions
… and the need for a trained operator. This study presents a colorimetric pH detection paper-based sensing as a promising technology which has the potential to replace conventional methods such as spectrophotometry and electrochemical methods for in-field screening of nitrogen-containing compounds. …
-
Microfluidic Detection of Waterborne Pathogen through Light Scattering of Particle Immunoassays
… method was essentially one-step and requires no sample pre-treatment or cell culturing. Conventional immunoassay using polyclonal antibody detects not only viable cells, but also dead cell and free antigens. In order to reduce false positive signal originated from dead cells and free antigens, …
-
Paper-Based Extraction and Amplification of Bacterial Genomic DNA to Monitor Food Safety
… a species. However, PCR is reliant on proper sample pre-treatment to remove inhibitory contaminants which can affect downstream results, which leads to a trade-off between detection time and sensitivity of results. Rolling circle amplification (RCA) is another potential detection reaction …
-
Point-of-need biosensors for the detection of respiratory biomarkers
… Although the test performed well using neat samples, it failed to identify EPX in clinical sputum samples. Analyzing pre-treatment methods identified that a quick immunoprecipitation technique using protein A/G beads followed by syringe filtration allowed for the device to successfully …
-
A Lab-on-a-Chip for automated RNA extraction from bacteria
… A crucial factor for such systems is the preparation of sample before the analysis can take place. Such sample pre-treatment needs to be automated, downscaled and finally integrated with a detection instrument, in order to construct a fully automated diagnostic system. Lab-on-a-Chip …
-
Radiogenic isotopic systematics of layered intrusions : application to the Mesoproterozoic Kiglapait intrusion of coastal Labrador, Canada, and to mafic-ultramafic rock reference materials
… Kiglapait intrusion (Labrador, Canada) represents a remarkable case study of how these intrusions form under closed-system crystallization of basaltic magma. The Kiglapait intrusion is the largest and youngest troctolitic intrusion contained within the vast Nain Plutonic Suite, one of the …
-
Selenium speciation and localization in sediment and benthic invertebrates from lakes receiving treated metal mine effluent
… fluorescence (XRF) imaging, which require little sample pre-treatment, were employed to study the speciation and distribution of Se in complex sediment and benthic invertebrates samples collected from the field. Laboratory based inductively coupled plasma mass spectrometry (ICP-MS) provided …