  1. The Impact of Sample Tilt on Scanning Transmission Electron Microscopy in Strontium Titanate

    … of ABFSTGEM imaging has shown that when a sample is tilted by 6 mrad relative to the electron beam, it creates artificial displacements of 11.9 pm between oxygen and cation columns. Artifacts of this magnitude make picometer-scale measurements of oxygen displacements impossible. However, …

    cornell Repository record for The Impact of Sample Tilt on Scanning Transmission Electron Microscopy in Strontium Titanate (opens in a new tab)

  2. Toward dual-probe atomic force microscopy at low temperatures: sample-tilt control and variable-friction stick–slip nanopositioning

    … concept in which coarse goniometer motion, fine tilt compensation, and z-axis piezo regulation coordinate simultaneous probe–sample engagement. Common- and differential-mode combinations of the two cantilever-amplitude signals distinguish shared interaction error from probe imbal ance. The …

    texas Repository record for Toward dual-probe atomic force microscopy at low temperatures: sample-tilt control and variable-friction stick–slip nanopositioning (opens in a new tab)

  3. Task-specific uncertainty of areal surface texture measurement using structured illumination microscopy

    … vertical scanning interval, exposure time, and sample tilt. The results show that the measurement settings influence the non-measured points, measurement noise, and areal surface texture parameters. Therefore, according to the investigation, the sample tilt and exposure time should also be …

    qucosa-diss

  4. Quantitative energy dispersive x-ray spectrometry using an Emispec Vision system

    … A series of tests performed with a standard NiO sample revealed that the TEM column and EDS detector were operating in a satisfactory fashion. NiO spectra acquired with different sample tilt- angles were used to test the Emispec software. An improved setup configuration, in which accurate …

    nps Repository record for Quantitative energy dispersive x-ray spectrometry using an Emispec Vision system (opens in a new tab)

  5. Spin resolved cyclotron resonance in indium antimonide quantum wells.

    … of the same spin Landau levels depend on the tilt of the sample with respect to the magnetic field direction. This result is consistent with earlier, non spin-resolved, studies of Landau level coupling in GaAs quantum wells. We also observed anti-crossings associated with Landau Levels of …

    oklahoma-thes Repository record for Spin resolved cyclotron resonance in indium antimonide quantum wells. (opens in a new tab)

  6. Quantitative atomic resolution characterisation of internal interfaces in doped bismuth ferrite

    … in the case studied here. It is shown that the sample tilt has no in uence on the polarisation measurements in this case as the direction of the sample tilt in our case is perpendicular to the direction of polarisation. It is shown that the ultra-thin sample used in HRTEM had a reduced …

    glasgow Download PDF for Quantitative atomic resolution characterisation of internal interfaces in doped bismuth ferrite (opens in a new tab)

  7. Characterisation of III-nitrides in the scanning electron microscope

    … extend ECCI to the study of insulating samples, ECCI micrographs were acquired in a variable pressure scanning electron microscope (VP-SEM) at pressures ranging from 0.3 mbar to 0.8 mbar using gaseous secondary electron detectors (GSEDs). ECCI micrographs are produced by detecting a …

    strathclyde Repository record for Characterisation of III-nitrides in the scanning electron microscope (opens in a new tab)

  8. Sources of error in relating nanoindentation results to material properties

    … part of the work is a study of the effect of sample tilt on results of nanoindentation tests. Geometrical relations are used to develop a correction to account for the effect of tilt angle on the contact area. 3D FEA (Finite Element Analysis) shows that the assumptions made in deriving the …

    wichita-thes Repository record for Sources of error in relating nanoindentation results to material properties (opens in a new tab)

  9. CHARGING EFFECTS IN LOW : VOLTAGE SCANNING ELECTRON MICROSCOPE METROLOGY

    … resist features in low voltage SEM. The beam-sample interactions parameters are measured in scanning electron microscope (SEM). The SE yield of Si and Au are measured at different primary beam energies and sample tilt angles. It is found that the SE yield dependence on beam incident angle is …

    nus Repository record for CHARGING EFFECTS IN LOW : VOLTAGE SCANNING ELECTRON MICROSCOPE METROLOGY (opens in a new tab) Download file for CHARGING EFFECTS IN LOW : VOLTAGE SCANNING ELECTRON MICROSCOPE METROLOGY (opens in a new tab)

  10. Local circular scanning for autonomous feature tracking in atomic force microscopy

    … the local raster scan (LRS), follows polymer samples, such as DNA or actin filaments, by detecting structural edges in real time and steering the probe in a sinusoidal path across the strand. While this has been shown to reduce scanning time by one order of magnitude, it is limited by …

    bu Repository record for Local circular scanning for autonomous feature tracking in atomic force microscopy (opens in a new tab) Embargoed until 2999-01-01

  11. Optical Coherence Tomography through Fibre Bundles by Angled Divergent Illumination

    … off-axis, making angled illumination onto the sample and the bundle face at 14◦. At this large angular incidence of the reference beam onto the bundle, the light coupled within cores was not suitable for OCT, mainly due to a large degree of coupling into higher order modes, and a low overall …

    kent Download PDF for Optical Coherence Tomography through Fibre Bundles by Angled Divergent Illumination (opens in a new tab)

  12. Electron beam charging of polymers in a scanning electron microscope

    … to minimize the problems associated with sample charging and therefore view unprepared, bulk insulating samples in the SEM without the need for metal coatings which obscure surface fine structure. Changes in a variety of operating parameters can be utilized to decrease the problems …

    ut-knoxville Repository record for Electron beam charging of polymers in a scanning electron microscope (opens in a new tab)

  13. Applications of Transmission Electron Microscopy on Free-standing and Embedded Two-dimensional Materials

    … and highlight the complexities of electron-sample interactions which can be used to extract additional information from experimental results. The first uses experimentally observed Moire patterns to correlate and understanding rotational misalignments of Bi2Se3; the second exploits the …

    umn Repository record for Applications of Transmission Electron Microscopy on Free-standing and Embedded Two-dimensional Materials (opens in a new tab)

  14. Magnetic Characterization of Electrodeposited Nanocrystalline Ni and Ni-Fe alloys

    … technique. The as-deposited Ni and Ni-15%Fe sample was comprised exclusively of the γ phase with lattice parameter of 3.5270 (nm) and 3.5424 (nm), respectively. The small increase in lattice parameter was attributed to the replacement of iron solutes in the Ni sites in lattice. Texture …

    mcmaster Repository record for Magnetic Characterization of Electrodeposited Nanocrystalline Ni and Ni-Fe alloys (opens in a new tab)

  15. Feasibility of Ellipsometric Sensor Development for Use During PECVD SiOx Coated Polymer Product Manufacturing

    … the characterization experiments, NS3 provided samples, both SiOX coated and uncoated, of various deposition thicknesses on silicon and biaxially oriented PET substrates. Null ellipsometry was used in conjunction with spectroscopic reflectometry to characterize the refractive index and thickness …

    calpoly Repository record for Feasibility of Ellipsometric Sensor Development for Use During PECVD SiOx Coated Polymer Product Manufacturing (opens in a new tab)