Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 6 of 6 for “"scanning light ophthalmoscopy"”
-
Comprehensive Framework for Machine Learning-Enabled Adaptive Optics Scanning Light Ophthalmoscopy
<p>Adaptive optics scanning light ophthalmoscopy (AOSLO) enables cellular-resolution imaging of the living human retina by correcting ocular aberrations and isolating light originating from the focal plane. In addition to conventional confocal imaging, nonconfocal detection methods have expanded …
-
Cone photoreceptor structure and function in choroideremia assessed using adaptive optics scanning light ophthalmoscopy
… changes in CHM. This thesis uses adaptive optics scanning light ophthalmoscopy (AOSLO) to achieve non-invasive in vivo imaging of the photoreceptor inner segment and waveguiding outer segment mosaics with single-cell resolution. Additionally, we have equipped our AOSLO with AO-guided …
-
Automated Robust Strip-Based Registration for AOSLO Retinal Vasculature Imaging
Non-confocal adaptive optics scanning light ophthalmoscopy (AOSLO) AVI se- quences of the retinal microvasculature imaging often contain eye-motion distortion, blink-corrupted frames, and frame-to-frame intensity variations that can weaken ref- erence frame selection and lower the quality of the …
-
Retinal Phenotyping of Inherited Retinal Diseases
… (FAF) imaging, and Adaptive Optics Scanning Light Ophthalmoscopy; and (ii) functional assessments, including visual acuity, contrast sensitivity, colour vision, static perimetry and microperimetry. Indices to quantify and investigate interocular symmetry, repeatability and …
-
Assessment of retinal structure and function in Stargardt Disease using indepth advanced phenotyping in preparation for therapeutic intervention
… autofluorescence (FAF), and adaptive optics scanning light ophthalmoscopy (AOSLO). Retinal function was investigated using visual acuity, contrast sensitivity, full-field static perimetry, and microperimetry. Reliable and sensitive metrics were established for application in natural history …
-
Imaging at the Limits: Segmentation Error Bounds and High Resolution Retinal Imaging Systems
… optical imaging technique that utilizes coherent light to produce 3-D images with resolutions as fine as a micrometer. Since its invention in 1990, it has become part of the standard of care in opthalmology, shedding new light on the progression of diseases, therapeutic efficacy, childhood …