Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 67 for “"scanning time"”.

  1. A Quasi-distributed Sensing Network Based on Wavelength-Scanning Time-division Multiplexed Fiber Bragg Gratings

    … work, we proposed and demonstrated a wavelength-scanning time-division multiplexing (WSTDM) of 1000 ultra-weak FBGs for distributed temperature sensing. In comparison with the OFDR method, the WSTDM method distinguishes the sensors by different time delays, and its maximum operation distance, …

    vt Repository record for A Quasi-distributed Sensing Network Based on Wavelength-Scanning Time-division Multiplexed Fiber Bragg Gratings (opens in a new tab)

  2. Influence of antenna pattern on synthetic aperture radar (SAR) imaging and complex permittivity extraction from images of multilayered media

    … system, factors including image production time, image quality, and capability to get quantitative information from a produced SAR image are commonly investigated. Implementation of SAR imaging usually requires two steps, namely; image data collection, and post processing of the collected …

    iastate Repository record for Influence of antenna pattern on synthetic aperture radar (SAR) imaging and complex permittivity extraction from images of multilayered media (opens in a new tab)

  3. Impact of Scanning Protocol on the Clinical Outcome of Tooth-Borne Complete Arch Rehabilitation

    Background: Intraoral scanning (IOS) of complete arches is a challenging aspect of clinical dentistry. The accuracy of IOS is vital to ensure a clinically acceptable restoration. Given the rapid advance and integration of digital technology into the profession, evaluating the clinical outcome of …

    buffalo Repository record for Impact of Scanning Protocol on the Clinical Outcome of Tooth-Borne Complete Arch Rehabilitation (opens in a new tab)

  4. Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging

    … patient breathing patterns and the nature of the scanning time differences between PET and CT, current respiratory-gated CTAC protocols for the irregular breather may cause additional bias in the PET image values. A ten-fold extension of the CT scanning time duration helps reduce PET imaging bias, …

    washington Repository record for Ultra-low-dose CT-based attenuation correction for respiratory motion compensation in PET/CT imaging (opens in a new tab)

  5. Splines on disk and cylindrical domains with application to MRI reconstruction

    … A problem remaining in MRI is the long scanning time which results in image motion artifact and patient discomfort. Techniques that can reduce acquisition time by sampling less data are usually accompanied with the reduction in image quality. This thesis is thus aiming to develop …

    ttu Repository record for Splines on disk and cylindrical domains with application to MRI reconstruction (opens in a new tab)

  6. Cardiovascular Magnetic Resonance Imaging for the Investigation of Patients with Coronary Heart Disease

    … adapts the spatial resolution to the available scanning time and field-of-view. Study 4: A multi-centre pragmatic randomised controlled trial of patients with stable angina comparing CMR guided-care Vs. SPECT guided-care Vs. National Institute of Health and Care Excellence guided-care. Results …

    whiterose Download PDF for Cardiovascular Magnetic Resonance Imaging for the Investigation of Patients with Coronary Heart Disease (opens in a new tab)

  7. Multi-channel Scanning SQUID Microscopy

    … assembled, and tested an 8-channel high-Tc scanning SQUID system. I started by modifying an existing single-channel 77 K high-Tc scanning SQUID microscope into a multi-channel system with the goal of reducing the scanning time and improving the spatial resolution by increasing the …

    maryland Repository record for Multi-channel Scanning SQUID Microscopy (opens in a new tab)

  8. Estimation of Doppler and polarimetric variables for weather radars.

    … phase components are taken at a rate several times larger than the reciprocal of the transmitted pulse length. The aforementioned radar variables are estimated by suitably combining weighted averages of these oversampled signals in range with usual processing of samples (spaced at pulse …

    oklahoma-thes Repository record for Estimation of Doppler and polarimetric variables for weather radars. (opens in a new tab)

  9. Image Reconstruction Using Generative Adversarial Networks with a Hybrid Loss

    … data is undersampled in order to reduce the scanning time and improve the patient experience. In this case, image reconstruction algorithm becomes important to maintain the image quality using only undersampled data. Deep learning methods have demonstrated great potential in MR image …

    buffalo Repository record for Image Reconstruction Using Generative Adversarial Networks with a Hybrid Loss (opens in a new tab)

  10. Efficient Handover Methods for Vehicle-to-Infrastructure Communications Over Heterogeneous Wireless Networks

    … network performance is achieved by reducing the scanning time of the candidate networks. The surveyed literature has shown that the network load at the target network has a significant impact on the handover performance due to an increased handover drop probability. For example, a macro-cell BS …

    auckland-tech Repository record for Efficient Handover Methods for Vehicle-to-Infrastructure Communications Over Heterogeneous Wireless Networks (opens in a new tab)

  11. First Arrival Differential LiDAR

    … significant limitations: (a) the additional time-of-arrival dimension results in a data throughput bottleneck, (b) limited spatial resolution due to either low fill-factor (flash LiDAR) or scanning time (scanning-based LiDAR), and (c) course depth resolution due to quantization of photon …

    rice Repository record for First Arrival Differential LiDAR (opens in a new tab)

  12. Frequency diverse array radar

    Electronic scanning is the most desirable feature of state-of-the-art radar systems. With electronic scanning, it is possible to steer the main beam of an array antenna instantaneously into a desired direction where no mechanical mechanism is involved in the scanning process. Electronic scanning …

    nps Repository record for Frequency diverse array radar (opens in a new tab)

  13. MEMORY FUNCTIONING IN PARKINSON'S DISEASE: THE EFFECT OF AGE OF ONSET ON HIGH SPEED MEMORY SCANNING.

    … were assessed for their speed of primary memory scanning speed using the Sternberg memory scanning paradigm. In addition, all patients were assessed for cognitive functioning as measured by the Mattis Dementia Rating Scale and the Wechsler Memory Scale. Significant differences were found between …

    arizona-thes Repository record for MEMORY FUNCTIONING IN PARKINSON'S DISEASE: THE EFFECT OF AGE OF ONSET ON HIGH SPEED MEMORY SCANNING. (opens in a new tab)

  14. Are there self-imposed group foraging costs in the nutmeg mannikin (Lonchura punctulata)?

    … The decrease occurred because they spent more time idle near the flock instead of feeding from the patch or immediately travelling to the next one. This seems to be a cost related to the maintenance of group cohesion. The birds also reduced their scanning time and rate near conspecifics without …

    concordia Download PDF for Are there self-imposed group foraging costs in the nutmeg mannikin (Lonchura punctulata)? (opens in a new tab)

  15. C-ARM TOMOGRAPHIC IMAGING TECHNIQUE FOR DETECTION OF KIDNEY STONES

    … helps to remain the patient stationary during scanning time. In this work, we investigated a C-arm technique to generate a series of tomographic images for nephrolithiasis and detection of kidney stones. C-arm tomographic technique (C-arm tomosynthesis) as a new three dimensional (3D) kidney …

    siu-theses Repository record for C-ARM TOMOGRAPHIC IMAGING TECHNIQUE FOR DETECTION OF KIDNEY STONES (opens in a new tab)

  16. Emission source microscopy for electromagnetic interference source localization

    … sources of radiation. Near-field electromagnetic scanning is used often for root-cause diagnosis by determining field distribution close to the PCB. In the near-field, the evanescent waves are dominant, which may lead to the misinterpretation of them being the dominant sources contributing to the …

    must-thes Repository record for Emission source microscopy for electromagnetic interference source localization (opens in a new tab)

  17. Adaptive attenuation correction tool

    … It requires much shorter transmission scanning time while producing better attenuation correction results. Clinical use of the technology should result in a dramatic reduction of patient bed-time and potentially better quantitative PET studies.</p>

    ut-knoxville Repository record for Adaptive attenuation correction tool (opens in a new tab)

  18. Simulation Analysis Of Bluetooth Scanning Systems

    … to investigate the failure probability of a scanning job conducted by a Bluetooth Low-Energy scanner on a group of items. Each item is outfitted with a BLE device and are sorted into large, batch sizes to be moved into the scanning area. The BLE device broadcasts packets, known as …

    mississippi Repository record for Simulation Analysis Of Bluetooth Scanning Systems (opens in a new tab)

  19. Patient-Device Association and Disassociation with a Real-Time Location System

    … involve bar-coding systems, which still require scanning time, are prone to errors, and do not solve equipment location issues. This thesis introduces a new system that exploits Real-Time Location System (RTLS) technology to track patients and devices and support simpler association by a nurse, …

    ottawa-retro Repository record for Patient-Device Association and Disassociation with a Real-Time Location System (opens in a new tab)

Page 1 of 4