  1. The design of a laser range imaging device

    … with a fully programmable X-Y galvonometric scanning unit. The scene, which can be dark as well as brightly lit, is scanned in either a vector or raster mode and both range and reflected intensity data are collected. In addition to typical range data applications, the range and intensity …

    rice Repository record for The design of a laser range imaging device (opens in a new tab)

  2. A piezoelectric fiber scanner for reflectance confocal imaging of biological tissues

    … microscopy techniques such as confocal laser scanning microscopy provide images for biological tissues at a micrometer level. The challenge is to miniaturize the system into a form of hand-held devices or catheters. The developed system in this thesis consists of a portable scanner probe and a …

    ubc Repository record for A piezoelectric fiber scanner for reflectance confocal imaging of biological tissues (opens in a new tab) Download PDF for A piezoelectric fiber scanner for reflectance confocal imaging of biological tissues (opens in a new tab)

  3. An Investigation of some of the Physical Processes Occuring in High Current Ion Sources

    … comparable electrical efficiency. An electronic scanning unit has been developed and used in conjunction with a two-dimensional wall probe array mounted in the extraction electrode and to determine the uniformity profile for the rectangular multipole source. This source is found to produce a …

    aston Repository record for An Investigation of some of the Physical Processes Occuring in High Current Ion Sources (opens in a new tab) Download PDF for An Investigation of some of the Physical Processes Occuring in High Current Ion Sources (opens in a new tab)

  4. A comparison of crown marginal fit fabricated using digital and conventional methods

    … bicuspid were recorded using a 3M LAVA C.O.S. scanning unit. Scan files were exported as .STL files and e-mailed to the dental lab. Files were inputed (Core3dcentres®; Las Vagas, Nevada, USA) into a digital design workflow for digital articulation, digital wax-up, and design of the final crown. …

    ubc Repository record for A comparison of crown marginal fit fabricated using digital and conventional methods (opens in a new tab) Download PDF for A comparison of crown marginal fit fabricated using digital and conventional methods (opens in a new tab)

  5. Calibration of Multi-Sensor Laser Scanning Systems

    Over the past few years, LiDAR or laser scanning systems (airborne, static and terrestrial mobile mapping systems) are considered as well-accepted technologies that can quickly acquire precise 3D point clouds of the terrain surfaces. On the functional level, any mobile system could be defined as an …

    calgary Repository record for Calibration of Multi-Sensor Laser Scanning Systems (opens in a new tab)

  6. Initial studies of two-photon line excitation array detection fluorescence microscopy

    … fluorescence microscope combines rapid, line-scanning and fast imaging with a 16-channel photomultiplier tube array to be able to achieve high imaging frame rates. The 2P-LEAD fluorescence microscope studied in this thesis uses a galvanometric scanning mirror which is capable of imaging ~2,600 …

    texas Repository record for Initial studies of two-photon line excitation array detection fluorescence microscopy (opens in a new tab)

  7. Field-resolved infrared spectroscopy based on thulium fiber laser technology

    … detection with a newly-implemented rapid scanning unit with a time resolution of 26 μs per single scan is examined for the application of high-throughput flow cytometry.

    lmu-germany Repository record for Field-resolved infrared spectroscopy based on thulium fiber laser technology (opens in a new tab)

  8. Μελέτη διεγέρσεων στη χρήση μαγνητομέτρου SQUID με εφαρμογή σε μη καταστροφικούς ελέγχους

    … fifth chapter, we present the complete measuring unit for experimental investigations with SQUID sensor. We analyze the SQUID magnetometers (single and double) which are integrated to a scanning unit, the aluminum plates that are investigated, the necessity of using “double-D” excitation coil, the …

    greece Repository record for Μελέτη διεγέρσεων στη χρήση μαγνητομέτρου SQUID με εφαρμογή σε μη καταστροφικούς ελέγχους (opens in a new tab)

  9. Rozpoznávání markantních rysů na nábojnicích

    Cílem této práce je návrh a implementace algoritmu, který dokáže porovnat dva obrazy pláště ná- bojnice na základě markantů v nich obsažených. V první části se věnuje problematice palných zbraní, zejména z pohledu balistických povýstřelových stop. V dalších částech pak představuje návrh a rea- …

    brno-tech Repository record for Rozpoznávání markantních rysů na nábojnicích (opens in a new tab)