Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"scatter correction"”.

  1. Scatter correction in Positron Emission Tomography

    … distribution and concentration. Physical scattering of one of the two coincident y-rays inside the medium supporting the metabolite will result in a mispositioning of the decayed radio-tracer. The set of all scattered events, following acquisition, will contribute background to the set of …

    ubc Repository record for Scatter correction in Positron Emission Tomography (opens in a new tab) Download PDF for Scatter correction in Positron Emission Tomography (opens in a new tab)

  2. Implementation of an analytically based scatter correction in SPECT reconstructions

    Photon scatter is one of the main effects that degrade the quality and quantitative accuracy of SPECT images. The objective of the work performed in this thesis was to develop and validate a scatter correction technique that uses an accurate physics-based model of photon scatter as part of an …

    ubc Repository record for Implementation of an analytically based scatter correction in SPECT reconstructions (opens in a new tab) Download PDF for Implementation of an analytically based scatter correction in SPECT reconstructions (opens in a new tab)

  3. X-ray CT scatter correction by a physics-motivated deep neural network

    … problem in X-ray Computed Tomography (CT) is the scatter occurring due to the interaction of photons with the imaged object. Unless it is corrected, this phenomenon manifests itself as degradations in the reconstructions in the form of various artifacts. This makes scatter correction a critical …

    uiuc Repository record for X-ray CT scatter correction by a physics-motivated deep neural network (opens in a new tab)

  4. Novel methods for scatter correction and dual energy imaging in cone-beam CT

    … scans and poor image quality mainly due to scatter contamination are the two bottlenecks of cone-beam CT (CBCT) imaging. This study investigates a method that combines measurement-based scatter correction and a compressed sensing (CS)-based iterative reconstruction algorithm to generate …

    gatech Repository record for Novel methods for scatter correction and dual energy imaging in cone-beam CT (opens in a new tab)

  5. Development of methods for time efficient scatter correction and improved attenuation correction in time-of-flight PET/MR

    … hierfür ist eine TOF-Erweiterung des single scatter simulation Ansatzes (TOF-SSS). Diese Methode wurde im Rahmen der TOF-Erweiterung von THOR implementiert. Der größte Nachteil der TOF-SSS ist eine 3–7-fach erhöhte Rechenzeit für die Berechnung der Streuschätzung im Vergleich zur non-TOF-SSS, …

    qucosa-diss

  6. Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy

    … Hounsfield Units as a result of in-patient scatter. The specific aims of this dissertation research are to: 1) reduce noise associated with the low-dose CBCT scans acquired with low tube current/time (mAs) protocols by the application of innovative software; and 2) develop a moving blocker …

    utswmed Repository record for Optimizing Kilovoltage Cone-Beam Computed Tomography for Image-Guided Radiation Therapy (opens in a new tab)

  7. Improving attenuation corrections obtained using singles-mode transmission data in small-animal PET

    … within the subject being imaged. These corrections can be obtained using singles-mode photon transmission scanning. Although suitable for small animal PET, these scans are subject to high amounts of contamination from scattered photons. Currently, no accurate correction exists to account …

    ubc Repository record for Improving attenuation corrections obtained using singles-mode transmission data in small-animal PET (opens in a new tab) Download PDF for Improving attenuation corrections obtained using singles-mode transmission data in small-animal PET (opens in a new tab)

  8. A Scheme for Ultra-Fast Computed Tomography Based on Stationary Multi-Beam X-ray Sources

    … interior CT: interior CT mode, X-ray scattering, and scatter correction methods. First, a single CNT X-ray source based interior micro-CT was constructed to serve as a down-scaled experimental verification platform for interior CT mode. Interior CT mode demonstrated comparable …

    vt Repository record for A Scheme for Ultra-Fast Computed Tomography Based on Stationary Multi-Beam X-ray Sources (opens in a new tab)

  9. Spectral Signature and Correction of Scattered Radiation in Energy-Resolved X-ray Imaging

    … and characterization. However, radiation that scatters from the object and reaches the detector is a long-standing problem that reduces image quality and quantitative accuracy. Previous studies to characterize and account for the scattered radiation have been limited to conventional x-ray …

    houston Repository record for Spectral Signature and Correction of Scattered Radiation in Energy-Resolved X-ray Imaging (opens in a new tab)

  10. Quantitative dedicated cone beam breast CT imaging

    … detection and diagnosis. Nevertheless, high scatter contamination stemming from large irradiation volume results in severe contrast lost and shading artifacts, impeding the quantitative uses of CBBCT in certain clinical tasks. Existing scatter correction methods demonstrate different …

    gatech Repository record for Quantitative dedicated cone beam breast CT imaging (opens in a new tab)

  11. Investigation and Development of a Fully 3D Tilt Capable Hybrid SPECT - CT System for Dedicated Breast Imaging

    … of fully 3-D trajectories on reconstructed image scatter correction, absorbed dose and Hounsifeld Unit accuracy, and [2] design, develop and implement the fully flexible, third generation hybrid SPECT-CT system capable of traversing complex 3D orbits about a pendant breast volume, without …

    duke Repository record for Investigation and Development of a Fully 3D Tilt Capable Hybrid SPECT - CT System for Dedicated Breast Imaging (opens in a new tab)

  12. Ga-67 imaging with vector

    … include evaluation of the attenuation and scatter correction, and finally optimization for Ga-67 imaging which includes proper selection of a MPC and the photopeaks for data reconstruction. Our results showed that the peak sensitivity of the GPMP, HECMP, and HSMP collimators at (93, 184, …

    ubc Repository record for Ga-67 imaging with vector (opens in a new tab) Download PDF for Ga-67 imaging with vector (opens in a new tab)

  13. An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality

    … of the annihilation photons undergo a Compton scattering in the object. This is more serious for a scanner operated in 3D mode or with large patients, where the scatter fraction can be as high as 40-60%. When one or both photons are scattered, the line of response (LOR) defined by connecting …

    manitoba Repository record for An investigation into the use of scattered photons to improve 2D Position Emission Tomography (PET) functional imaging quality (opens in a new tab)

  14. Development of scatter reconstruction algorithms to 3-dimensional positron emission tomography

    … of the detected photon coincidences arising from scatter can be very high, up to 60%. A standard approach to scatter correction in 3D PET is to estimate the scattered coincidences and subtract them from the list of recorded events. More recently, novel techniques have been proposed in which the …

    manitoba Repository record for Development of scatter reconstruction algorithms to 3-dimensional positron emission tomography (opens in a new tab)

  15. ASSESSMENT OF ACTIVITY QUANTIFICATION ACCURACY IN PET/MR IMAGING

    … FROM BOTH STUDIES SUGGEST THAT ATTENUATION CORRECTION DIFFERENCES BETWEEN PET/MR AND PET/CT SYSTEMS IS A MAJOR CAUSE OF DIFFERENCES IN MEASURED ACTIVITY. DIFFERENCES IN SCATTER CORRECTION BETWEEN BOTH SYSTEMS ONLY ACCOUNT FOR A SMALL BUT SIGNIFICANT DIFFERENCE IN MEASURED ACTIVITY. A NOVEL …

    nus Repository record for ASSESSMENT OF ACTIVITY QUANTIFICATION ACCURACY IN PET/MR IMAGING (opens in a new tab) Download file for ASSESSMENT OF ACTIVITY QUANTIFICATION ACCURACY IN PET/MR IMAGING (opens in a new tab)

  16. 4D Dynamic Contrast-Enhanced Breast CT: System Optimization and Quantitative Validation

    … The work introduces a deep learning-based scatter correction method, compares first- and second-generation breast CT systems demonstrating improvements in resolution and dose efficiency, and develops optimized acquisition and reconstruction strategies to enhance iodine contrast visibility …

    radboud Repository record for 4D Dynamic Contrast-Enhanced Breast CT: System Optimization and Quantitative Validation (opens in a new tab)

  17. Attenuation Correction in Positron Tomography

    <p>Accurate attenuation correction is a prerequisite for the determination of precise regional radioactivity concentrations in positron tomography. Attenuation correction can be performed using an external source of radiation and two measurements: a blank scan performed with no subject in the …

    mcmaster Repository record for Attenuation Correction in Positron Tomography (opens in a new tab)

Page 1 of 4