Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 114 for “"scattering coefficient"”.

  1. Measurement traceability of sound scattering coefficient of diffusive surfaces used in room acoustics and virtual acoustical environments

    … measurements (only the random-incidence scattering coefficient has been considered), and further studies the effects of this accuracy on the objective room acoustic parameters, on the accuracy of simulation results and on perception. Knowing this interactions would give a measure of how …

    poli-torino Repository record for Measurement traceability of sound scattering coefficient of diffusive surfaces used in room acoustics and virtual acoustical environments (opens in a new tab)

  2. Modeling of ultrasonic scattering experiments with applications to system and transducer characterization

    … the observable quantity in an ultrasonic scattering experiment, is written as a product, in the frequency domain, of two factors: the system efficiency and the scattering coefficient. The system efficiency represents the combined electrical properties of both the generator and receiver …

    iastate Repository record for Modeling of ultrasonic scattering experiments with applications to system and transducer characterization (opens in a new tab)

  3. Συσχέτιση των χημικών ιδιοτήτων με οπτικές και κλιματικές παραμέτρους των αιωρούμενων σωματιδίων στην ευρύτερη περιοχή των Αθηνών

    … 11% of EC, IM and POM is local. Daily values of scattering coefficient give an average of 30.1±3.9 Μm-1 while, the mean value of absorption coefficient is 5.2±1.4 Μm-1. Scattering coefficient is significantly affected by fine particles and the included sulphate ions while, absorption coefficient …

    greece Repository record for Συσχέτιση των χημικών ιδιοτήτων με οπτικές και κλιματικές παραμέτρους των αιωρούμενων σωματιδίων στην ευρύτερη περιοχή των Αθηνών (opens in a new tab)

  4. Elucidating the nature of bonding in mechanical pulps

    … Ingmansson and Thode method relies on the use of scattering coefficient as a measure of specific surface area. It is shown that scattering coefficient is an accurate estimate of mechanical pulp specific surface area at a constant wavelength of light, provided that the wavelength used to measure …

    gatech Repository record for Elucidating the nature of bonding in mechanical pulps (opens in a new tab)

  5. A Method for Characterizing the Properties of Industrial Foams

    … were varied include the layer thickness, the scattering coefficient, and the asymmetry parameter. Layer thicknesses between 8.5 mm and 18 cm were considered. Values of the scattering coefficient ranged from about 600 m-1 to 14000 m-1, while the asymmetry parameter varied between 0 and 1. A …

    byu Repository record for A Method for Characterizing the Properties of Industrial Foams (opens in a new tab) Download PDF for A Method for Characterizing the Properties of Industrial Foams (opens in a new tab)

  6. Light scattering of semitransparent media

    Polytetrafluoroethylene (PTFE) is a highly scattering material and has been used as diffuse reflectors. In the present study, the ranges of the scattering coefficient, absorption coefficient, and the asymmetric parameter of the Henyey-Greenstein scattering phase function are assessed for …

    gatech Repository record for Light scattering of semitransparent media (opens in a new tab)

  7. Light transport in neonatal skin

    … the visible region from 450-750 nm. The reduced scattering coefficient, $\mu\sb{\rm s}$(1-g), increases directly with gestational maturity of the infant. The increase in the reduced scattering coefficient with gestational maturity is due to the accompanying increase in size and density of the …

    rice Repository record for Light transport in neonatal skin (opens in a new tab)

  8. Hiding power of white pigments : theory and measurement

    … of pigmented films such as hiding power, scattering coefficient, and absorption coefficient were measured at three bands of wavelength of light (blue, green, red) for ten white pigments at seven pigment concentrations in a paint. These pigments range from the highest index of refraction …

    njit Repository record for Hiding power of white pigments : theory and measurement (opens in a new tab)

  9. Geometric and boundary element method simulations of acoustic reflections from rough, finite, or non-planar surfaces

    … project in this dissertation investigates the scattering coefficient, which quantifies the degree of diffuse reflection from rough surfaces. The main result is that predicted reverberation time varies inversely with scattering coefficient if the sound field is nondiffuse. Additional results …

    nebraska Repository record for Geometric and boundary element method simulations of acoustic reflections from rough, finite, or non-planar surfaces (opens in a new tab)

  10. Radiative characterization of heterogeneous media for solar thermochemical applications

    … technique was devel- oped to infer transport scattering coefficient and absorption coefficient from measured transmittance and reflectance. An experimental setup to measure normal-emittance of materials employed in solar thermochemical applications is also designed. This experi- mental setup …

    umn Repository record for Radiative characterization of heterogeneous media for solar thermochemical applications (opens in a new tab)

  11. Determination of forest canopy sunlight absorption and scattering coefficients without direct measurement of leaf area index

    … using this method to obtain both absorption and scattering coefficients. The scattering coefficient is about the same size as the absorption coefficient, hence scattering should not be neglected as has often been done in the past.</p>

    ut-knoxville Repository record for Determination of forest canopy sunlight absorption and scattering coefficients without direct measurement of leaf area index (opens in a new tab)

  12. Double Integrating Sphere Characterization of PVA-Cryogels

    … emulsion and food colouring were used to impart scattering and absorbing properties in the range characteristic of human tissue. Measured values of normalized reflectances and transmittances were entered into IAD, and a set of optical properties (μ′s,μa,g) retrieved. The reduced scattering …

    mcmaster Repository record for Double Integrating Sphere Characterization of PVA-Cryogels (opens in a new tab)

  13. In Vivo Assessment of the Forward to Backward Ratio of Second Harmonic Generation By Collagen As Part of a Non-Invasive, All-Optical Biopsy for Skin Cancer

    … C’s dependence on a property of the tissue, the scattering coefficient. We also ran the simulation in a thin biopsy sample to model the collagen samples used experimentally in this project and observed C’s dependence on the scattering coefficient.

    creighton Repository record for In Vivo Assessment of the Forward to Backward Ratio of Second Harmonic Generation By Collagen As Part of a Non-Invasive, All-Optical Biopsy for Skin Cancer (opens in a new tab)

  14. Measurement of tissue optical properties during mechanical compression using swept source optical coherence tomography

    … penetration depth in tissue due to its highly scattering properties. The highly disordered refractive index distribution in tissue leads to multiple-scattering of incident light. It has been hypothesized that mechanical compression has a great potential to enhance the capabilities of laser …

    vt Repository record for Measurement of tissue optical properties during mechanical compression using swept source optical coherence tomography (opens in a new tab)

  15. Wavelength tuneable frequency domain photon migration spectrometer for tissue-like media

    … instrument estimates the absorption and reduced scattering coefficients with a precision of 3% and 6%, respectively. Optical properties of Intralipid were measured from 710-850 nm in the therapeutic window. The results were compared with published data measured by other methods and similar …

    waikato-masters Repository record for Wavelength tuneable frequency domain photon migration spectrometer for tissue-like media (opens in a new tab) Download file for Wavelength tuneable frequency domain photon migration spectrometer for tissue-like media (opens in a new tab)

  16. Light Signal Attenuation by Murine Cortical Bone for Quantification of Fluorescence Reflectance Imaging

    … The attenuation was quantified with the reduced scattering coefficient. This parameter was derived from a multivariate regression model that was based on the diffusion approximation to the transport theory. But it was not possible to resolve the wavelength-dependence of the reduced scattering …

    cau-kiel Repository record for Light Signal Attenuation by Murine Cortical Bone for Quantification of Fluorescence Reflectance Imaging (opens in a new tab)

  17. Near real time confocal microscopy of Ex Vivo cervical tissue: detection of dysplasia

    … upon Beer’s equation for light attenuation, the scattering coefficient was extracted from 3D image sets of ex vivo cervical tissue and compared with histology from the same precancerous lesion. The results suggested a possible correlation between high scattering values and the presence of …

    texas Repository record for Near real time confocal microscopy of Ex Vivo cervical tissue: detection of dysplasia (opens in a new tab)

  18. Assessment and Diagnosis of Human Colorectal and Ovarian Cancer using Optical Imaging and Computer-aided Diagnosis

    Tissue optical scattering has recently emerged as an important diagnosis parameter associated with early tumor development and progression. To characterize the differences between benign and malignant colorectal tissues, we have created an automated optical scattering coefficient mapping algorithm …

    wustl Repository record for Assessment and Diagnosis of Human Colorectal and Ovarian Cancer using Optical Imaging and Computer-aided Diagnosis (opens in a new tab)

  19. Assessment and Diagnosis of Human Colorectal and Ovarian Cancer using Optical Imaging and Computer-aided Diagnosis

    Tissue optical scattering has recently emerged as an important diagnosis parameter associated with early tumor development and progression. To characterize the differences between benign and malignant colorectal tissues, we have created an automated optical scattering coefficient mapping algorithm …

    wustl Repository record for Assessment and Diagnosis of Human Colorectal and Ovarian Cancer using Optical Imaging and Computer-aided Diagnosis (opens in a new tab)

Page 1 of 6