Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 26 for “"search coil"”.

  1. A computer-based eye movement recording system using the scleral search-coil technique

    … eye-movement recording system uses the scleral search coil technique. It has two recording channels, which is extremely important in the binocular vision studies. It consists of four basic elements: magnetic field coils to generate horizontal and vertical oscillating magnetic fields, two ocular …

    bu Repository record for A computer-based eye movement recording system using the scleral search-coil technique (opens in a new tab)

  2. Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis

    … and their operating characteristics. Research for fault diagnosis in last 5 years has lead to variety of techniques, but none have proved to be feasible either due to need for dedicated sensors and high computing needs or they fail to account for operating conditions which lead to …

    uvic Repository record for Stator inter-turn fault detection of doubly-fed induction generators using rotor current and search coil voltage signature analysis (opens in a new tab)

  3. Development of ground-based search -coil magnetometer systems in the polar regions and studies of ULF Pc 1--2 wave propagation in the ionospheric waveguide

    Search-coil magnetometers, which measure time-varying magnetic flux density (dB/dt) and its direction, have been developed for the observations of geomagnetic pulsations in the ultra low frequency (ULF) range (a few mHz to a few Hz). The design, fabrication, and test/calibration have been performed …

    unh-thes Repository record for Development of ground-based search -coil magnetometer systems in the polar regions and studies of ULF Pc 1--2 wave propagation in the ionospheric waveguide (opens in a new tab)

  4. Detection of Magnetic Nanoparticles for Bio-sensing Applications

    … biomarkers (protein, DNA, etc.) by using a search coil based scheme for volume detection and by using a Giant Magneto-Resistance (GMR) sensor for surface detection. In search coil detection scheme, a low frequency field is applied to saturate the MNPs and a high frequency field is applied to …

    umn Repository record for Detection of Magnetic Nanoparticles for Bio-sensing Applications (opens in a new tab)

  5. Capacitive Eye Tracker made of Carbon-Nanotube Paper Composite for Human-Machine Interface and Neuroscience Applications

    … for an eye-tracking device has been the scleral search coil system. Despite dominant camera-based eye-tracking systems, their bulky equipment's obtrusiveness and high-power consumption are considered challenging for wearable applications. Piezoelectric sensors, electrooculography (EOG), and …

    washington Repository record for Capacitive Eye Tracker made of Carbon-Nanotube Paper Composite for Human-Machine Interface and Neuroscience Applications (opens in a new tab)

  6. Magneto-Nanosensor Platforms for Biosensing Applications

    … applications based on two detection platforms: search coil-based biosensor (volumetric based biosensing platform) and giant magnetoresistance (GMR) biosensor (surface based biosensing platform). The volumetric based biosensing platforms measure analytical signals that come from the entire …

    umn Repository record for Magneto-Nanosensor Platforms for Biosensing Applications (opens in a new tab)

  7. Design, construction and testing of an autonomous mine hunter

    … would find application in concert with other search technologies. A detection circuit was designed and constructed consisting of a search coil and a CMOS exclusive OR gate forming an oscillator. This was interfaced to a microprocessor which counted the pulses from the oscillator and decided …

    nps Repository record for Design, construction and testing of an autonomous mine hunter (opens in a new tab)

  8. Cerebelläre Ataxie und bilaterale Vestibulopathie

    … (EMG/NLG, cVEMP, Audiometrie, VBM, Search-Coil). Die Untersuchungsergebnisse der beiden Gruppen wurden dabei jeweils miteinander verglichen. Folgende Kernaussagen können basierend auf diesen Studien getroffen werden: 1. Aus den Messungen mittels Search-Coil-Technik ergab sich, dass …

    lmu-germany Repository record for Cerebelläre Ataxie und bilaterale Vestibulopathie (opens in a new tab)

  9. Eye-Head-Hand Coordination During Visually Guided Reaches in Head-Unrestrained Macaques

    … hand motion were recorded in two animals using search coil and touch screen technology, respectively. Animals were seated in a customized chair which allowed unencumbered head motion and reaching in depth. In the reach condition, animals were trained to touch a central LED at waist level while …

    york Repository record for Eye-Head-Hand Coordination During Visually Guided Reaches in Head-Unrestrained Macaques (opens in a new tab)

  10. Distortion of amplitude and phase of alternating electromagnetic fields by presence of electrical conductors

    … the voltage induced in a small vertical search coil in the plane of the loop. Determinations of both the ratio of the horizontal field to the vertical, and the phase angle between them are made at various points along a diameter directly above the centre line of each conductor. …

    ubc Repository record for Distortion of amplitude and phase of alternating electromagnetic fields by presence of electrical conductors (opens in a new tab) Download PDF for Distortion of amplitude and phase of alternating electromagnetic fields by presence of electrical conductors (opens in a new tab)

  11. Untersuchungen der Blicksteuerung bei Patienten mit peripheren und zentralen okulomotorischen und vestibulären Störungen

    … von Probanden und Patienten mittels der Search Coil-Methode (Robinson 1963) und der Videookulografie analysiert (Übersicht in (Bedell und Stevenson 2013; Eggert 2007)). Zusätzlich wurde sehr eng mit Ingeni-euren, Physikern und Mathematikern zusammengearbeitet, um Methodik und Ana-lyse der …

    lmu-germany Repository record for Untersuchungen der Blicksteuerung bei Patienten mit peripheren und zentralen okulomotorischen und vestibulären Störungen (opens in a new tab)

  12. The Effect of Visual Attention on Eye Movements

    … during pursuit. In the last experiment, scleral search coil eye tracking system at a sampling rate of 500Hz was used to track torsional eye rotations (cycloversion and cyclovergence). Subjects wore red–green anaglyph glasses and were asked to hold their head and gaze steady on the central …

    houston Repository record for The Effect of Visual Attention on Eye Movements (opens in a new tab)

  13. New techniques for electric machine diagnostics using advanced signal processing and machine learning.

    … fault diagnosis models has become a major research interest. Classical diagnostics and fault detection methods for electric machines rely on spectral analysis of sidebands to indicate fault conditions. This approach requires expert knowledge and is prone to issues of false indications. In …

    baylor Repository record for New techniques for electric machine diagnostics using advanced signal processing and machine learning. (opens in a new tab)

  14. Sakkaden zu bewegten und stationären Zielen

    … bewegten und stationären Zielen wurden mittels search-coil-Methode aufgezeichnet. Dazu wurde den Affen ausgehend von einer durch einen sichtbaren Fixationspunkt bestimmten Ruhelage in unvorhersehbarer Reihenfolge Ziele dargeboten, auf die sie ihren Blick richten sollten. Letztere befanden sich …

    lmu-germany Repository record for Sakkaden zu bewegten und stationären Zielen (opens in a new tab)

  15. Temperature dependence studies of persistent currents in superconductors

    … current through the thin film were made with a search-coil coupled to the current's magnetic field. A relationship between the current changes observed and some momentum properties of superstate electrons was then established. The assumption that all "virtual pairs" in a superconductor have a …

    ubc Repository record for Temperature dependence studies of persistent currents in superconductors (opens in a new tab) Download PDF for Temperature dependence studies of persistent currents in superconductors (opens in a new tab)

  16. Development and Characterization of Ultrasensitive Carbon Nanotube Paper-Based Capacitive Sensors for Human-Machine Interfaces and Machine Learning-Enhanced Eye Tracking

    … small size. In this dissertation, I present my research on studying the proximity sensitivity of a capacitive sensor made of carbon-nanotube-paper-composite (CPC) and its application in HMI and wearable eye-trackers. CPC capacitive sensors had conductive cellulose fibers whose high aspect ratio …

    washington Repository record for Development and Characterization of Ultrasensitive Carbon Nanotube Paper-Based Capacitive Sensors for Human-Machine Interfaces and Machine Learning-Enhanced Eye Tracking (opens in a new tab)

  17. Stator fault analysis of synchronous machines

    … have also been realized using a rotor-mounted search-coil with very high sensitivity. In this work, an instrument has also been devised to implement fault diagnosis on machines using the computational capabilities of digital signal processors.

    uvic Repository record for Stator fault analysis of synchronous machines (opens in a new tab)

  18. Innovative vestibular testing

    … as the caloric test, the rotational test or the search-coil Head Impulse Test, present several disadvantages, being unpleasant, expensive, time-consuming, not always available at the bedside or appropriate for any group of patients. Additionally, testing the vestibular system at low frequencies, …

    lmu-germany Repository record for Innovative vestibular testing (opens in a new tab)

Page 1 of 2