TRANSIENT PERFORMANCE EVALUATION OF AUTOMOTIVE SECONDARY LOOP SYSTEMS
… Warming Potential, their flammability requires secondary loop systems to be used. The added thermal mass of such systems may increase power consumption and delay cool down while benefitting thermal comfort during start/stop operation. The recent revival of electric vehicles, as well as the …
-
Secondary loop reversible AC/HP system for electric vehicles
… presents experimentally obtained results of a secondary loop air conditioning-heat pump system compared to a baseline direct system. The secondary loop system has a refrigerant circuit operating between two 50/50 water glycol loops, and uses the identical compressor and accumulator as the …
-
Investigation of indirect (secondary loop) refrigeration systems in commercial food service buildings
Indirect (secondary loop) refrigeration systems have recently received increased attention due to their well-known effects on reducing refrigerant losses, particularly in commercial food sales buildings. Although their effects on operating costs, particularly in terms of energy efficiency, are less …
-
Modeling of Mobile Air Conditioning System
… passenger and reduce the refrigerant charge, a secondary loop system with coolant loop on both condenser and evaporator side was proposed. The performances of this system using R-134a, R-152a, and R-1234yf were evaluated and compared to that of conventional direct expansion system using R-134a …
-
Heat-transfer analysis of double-pipe heat exchangers for indirect-cycle SCW NPP
… NPPs, steam generators separate the primary loop from the secondary loop. In this way, the primary loop can be completely enclosed in a reactor containment building. This study analyzes the heat transfer from a SCW primary (reactor) loop to a SCW and Super-Heated Steam (SHS) secondary …
-
Optimization of a battery thermal management system: Master’s thesis in Sustainable Energy Systems
… System (BTMS) solutions. The ACU employs a secondary loop with a glycol-water mixture as the coolant for heat transfer, effectively separating the refrigerant from the battery cooling circuit. The ACU is critical for ensuring traction batteries operate within their ideal temperature range. …
-
The effect of availability improvement of a nuclear power plant on the cost of generating electricity
… as a result of improving the availability of the secondary (steam) loop of the plant. A new method has been developed to obtain availability, frequency of failure, probability and frequency of operation, cycle time, and uptime for different capacity states of a parallel-series system having …
-
Review of algorithms for RNA secondary structure prediction with pseudoknots
… that are formed from the base pairing of an RNA secondary loop structure with a complementary base which lies somewhere outside of the loop. The result is a structure, which plays a vital role in cell structure rigidity, regulation of protein synthesis, and in the structural organization of RNA …
-
Simulation of nuclear power plant pressurizers with application to an inherently safe reactor
… of three major components: (1) The primary loop, (2) The secondary loop, and (3) The natural convection loop through the pool. A lumped parameter model, uniform heat transfer, and point kinetics have been the main approximations in this model. Other approximations are mentioned during the …
-
Steam generator thermal-fluid simulation using a coupled Flownex and RELAP5/mod4.0 approach
… as a heat exchanger between the primary and secondary loops of a NPP. In addition to this the SG also serves as an important safety barrier since it separates the primary and secondary sides to avoid contamination of the secondary loop with radioactive material. Relap5 is a well-known …
-
Next Generation Thermal Management System Control Architecture for Battery Electric Vehicles
… will be investigating the performance of Full Secondary Loop (FSL) architecture which uses propane-based refrigerant and water-glycerol as coolant. The investigation in this project has been done using the Complete Vehicle Thermal Modelling (CVTM) simulation environment at Volvo Cars, which is …
-
New thermal management system for alternative refrigerants
The European Union has expressed concerns on the usage of some materials that may have a long-term effect on the ecosystem, particularly PFAS (per- and polyfluoroalkyl substances), in keeping with its continuous commitment to sustainability and the ethical use of resources. Regulations on the use …
-
Passive thermal management of distribution grid assets
… closed thermosiphon systems incorporating a secondary parallel flow path for cooling an additional, typically smaller, thermal load associated with the power electronics converters. Dual-loop thermosiphon passive thermal management systems were incorporated into a grounded compact dynamic …
-
Solid oxide fuel cell as a distributed generator: Dynamic modeling, stability analysis and control.
… help of a substation is presented. Two control loops are proposed for the SOFCs to guarantee that SOFC is protected and to track load changes and regulate the frequency. These two respective loops are called primary and secondary loops. Tuning of the secondary loop controller parameters are …
-
High efficiency, low cost, fully integrated DC-DC converter solution
… designed. The capacitive converter uses a dual loop control, where a single bound hysteretic control loop achieves regulation and the secondary loop achieves ripple control by modulating capacitance size and charge/discharge time of the capacitance used to transfer charge from the input to …
-
TOWARDS RELAY FEEDBACK AUTO-TUNING OF MULTI-LOOP SYSTEMS
… of PI/PID structures placed on them in a multi-loop fashion. This thesis is a step towards the autotuning of these controllers using the relay feedback technique. The thesis discusses the following; the effect of placing cascade and m x m multivariable plants under relay feedback, the …
-
CONTROL STRATEGIES OF DC MICROGRID TO ENABLE A MORE WIDE-SCALE ADOPTION
… hierarchy strategy consisting of two control loops is proposed to the DC microgrid in study, which is composed of two PV boost converters, two battery bi-directional converters and one multi-level packed-u-cell inverter with grid connected. The primary loop task is the control of each energy …
-
Demand-Side Load Management Using Single-Phase Residential Static VAR Compensators
… dissertation presents the concept of a closed-loop Residential Static VAR Compensator (RSVC) that will allow electric utility companies to locally regulate the voltage across the distribution feeder. The proposed RSVC is a novel smart-grid device that can regulate a residential load voltage …
-
Design of High-Density Filter Building Blocks for SiC-based Three-Phase Power Converters
… and the indirectly coupled FBB using a secondary loop interconnection is proposed as a viable modular FBB candidate. Correspondingly, for DC-AC inverters, modular filters can be realized using a masked impedance and decoupling approach. The test case being a DC-fed motor drive for …
-
Koncepční návrh jaderného zdroje na bázi malého modulárního reaktoru
Diplomová práce se věnuje koncepčnímu návrhu jaderného zdroje na bázi malého modulárního reaktoru s využitím v teplárenství. Pro návrh byl zvolen reaktor SMART. Pro parametry reaktoru bylo vytvořeno tepelné schéma sekundárního okruhu obsahující základní zařízení. Byla stanovena hmotnostní bilance a …