Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 22 for “"seismocardiography"”

  1. Seismocardiography: Practical implementation and feasibility

    … of themyocardium and also the blood flow. Seismocardiography (SCG) is a newly revived inexpensive method where local vibrations due to cardiovascular function are detected non-invasively from the sternum. These vibrations provide information about the mechanical function of the …

    aalto Repository record for Seismocardiography: Practical implementation and feasibility (opens in a new tab)

  2. Wearable health monitoring with seismocardiography and generative modeling

    Les maladies cardiovasculaires demeurent l’une des principales causes de mortalité et d'incapacité à l’échelle mondiale, soulignant le besoin crucial de détection précoce et de surveillance continue. Les technologies portables ont émergé comme une solution prometteuse, offrant une évaluation non …

    mcgill Repository record for Wearable health monitoring with seismocardiography and generative modeling (opens in a new tab)

  3. Effects of Exercise Training on Heart Failure Measured Using Seismocardiography

    … (LVET) and the pre-ejection period (PEP) using seismocardiography (SCG), as well as to investigate the functional health changes measured using the six-minute walk test (6MWT). Participants exercised three times per week for a period of 12 weeks involving a combination of aerobic and resistance …

    regina Repository record for Effects of Exercise Training on Heart Failure Measured Using Seismocardiography (opens in a new tab)

  4. Non-Invasive Cardiovascular Health Monitoring for Patients with Heart Failure using Seismocardiography

    … unobtrusively. A promising sensing modality is seismocardiography (SCG), defined as the measurement of local chest wall vibrations associated with the cardiac cycle. SCG has shown efficacy in tracking changes in cardiac contractility via the cardiac timing intervals it yields, such as the …

    gatech Repository record for Non-Invasive Cardiovascular Health Monitoring for Patients with Heart Failure using Seismocardiography (opens in a new tab)

  5. Seismocardiography - Genesis, and Utilization of Machine Learning for Variability Reduction and Improved Cardiac Health Monitoring

    Seismocardiography (SCG) is the measured chest surface vibrations resulting from cardiac activity. Although SCG can contain information that correlate with cardiac health, its utility may be limited by lack of understanding of the signal genesis and a variability that can mask subtle SCG changes. …

    ucf Repository record for Seismocardiography - Genesis, and Utilization of Machine Learning for Variability Reduction and Improved Cardiac Health Monitoring (opens in a new tab)

  6. SIGNAL PROCESSING AND ANALYSIS MODELS FOR NON-INVASIVE CARDIOVASCULAR AUTONOMIC MARKERS

    … research studies: one examining the use of seismocardiography (SCG) for PEP measurement during physiological challenges, another assessing the utility of multi-level modeling (MLM) for estimating the baroreceptor sensitivity index (BRSI) in individuals with spinal cord injury (SCI), and a …

    ku Repository record for SIGNAL PROCESSING AND ANALYSIS MODELS FOR NON-INVASIVE CARDIOVASCULAR AUTONOMIC MARKERS (opens in a new tab)

  7. Development of a multimodal framework for cardiac computed tomography gating

    … activity, is suboptimal. As an alternative, seismocardiography (SCG) that directly measures the mechanical motion of the heart has demonstrated its effectiveness in detecting cardiac quiescence. In this work, an SCG-based quiescence prediction method was developed, and reported improved …

    gatech Repository record for Development of a multimodal framework for cardiac computed tomography gating (opens in a new tab)

  8. Multimodal Predictive Frameworks for Cardiac Computed Tomography Gating

    … quiescent periods. Mechanical signals such as seismocardiography (SCG) and ultrasound (US) therefore offer promising alternatives for improving quiescence prediction. Although ultrasound has previously shown promise for identifying cardiac quiescence, its use during CT acquisition was limited …

    gatech Repository record for Multimodal Predictive Frameworks for Cardiac Computed Tomography Gating (opens in a new tab)

  9. Cuffless blood pressure monitoring technologies based on pulse transit time

    … associated with opening of the aorta, based on seismocardiography, and an optical sensor at the wrist measures the distal pulse wave. SeismoWatch is non-invasive and compact, allowing for convenient and portable blood pressure tracking.

    gatech Repository record for Cuffless blood pressure monitoring technologies based on pulse transit time (opens in a new tab)

  10. Study of Seismocardiographic Signal Variability, Denoising and Application in Cardiac Monitoring

    Seismocardiography (SCG) is the low frequency chest surface vibration generated by the mechanical activities of the heart. SCG has been found to have clinical utilities in diagnosis of different cardiac diseases. The first part of this study focused on the application of SCG signal in predicting …

    ucf Repository record for Study of Seismocardiographic Signal Variability, Denoising and Application in Cardiac Monitoring (opens in a new tab)

  11. Pulse-to-Pair: A Heartbeat-based Authentication Method for Body Area Networks

    … authentication and encryption system using Seismocardiography (SCG) and ECG signals, proposing an Inter-pulse Interval (IPI) alignment algorithm that substantially enhances the usability and efficiency, and investigating the impact of Valvular Heart Disease (VHD) on authentication. This is …

    queens Repository record for Pulse-to-Pair: A Heartbeat-based Authentication Method for Body Area Networks (opens in a new tab)

  12. Detection and prediction of cardiac quiescence for computed tomography coronary angiography

    … cardiac motion using either echocardiography or seismocardiography (SCG) should prove better at detecting and predicting periods of cardiac quiescence. Improved gating would permit the use of CTCA in more instances to either replace or determine the necessity of invasive and expensive CCAs. This …

    gatech Repository record for Detection and prediction of cardiac quiescence for computed tomography coronary angiography (opens in a new tab)

  13. Respiratory modulation of sternal accelerations

    … separate devices to analyze their performance. Seismocardiography (SCG) has the potential to monitor both aspects as it records the motion of the chest wall. SCG has been well developed for cardiovascular monitoring, however, there is limited knowledge on the effects of respiration. The …

    mcgill Repository record for Respiratory modulation of sternal accelerations (opens in a new tab)

  14. Multilabel Classification of Valvular Heart Diseases from Seismocardiogram Signals Using Machine Learning

    … effective. This thesis attempts to assess the Seismocardiography signal (SCG) as a non-invasive diagnostic modality for the early detection and supervision of VHD. The SCG signal is a new technique that is a non-invasive method of recording heart vibrations from the surface of the person’s …

    qucosa-diss Repository record for Multilabel Classification of Valvular Heart Diseases from Seismocardiogram Signals Using Machine Learning (opens in a new tab)

  15. Validity of the Polar Verity Sense Optical Armband and iPhone Accelerometer for Heart Rate Variability Assessment

    … optical armband and iPhone accelerometer (Kubois seismocardiography, SCG) against the Polar H10 across different body positions (for both devices) and measurement durations (for Verity Sense only) while accounting for skin pigmentation. Healthy young adults (n = 46) participated in simultaneous …

    gsu Repository record for Validity of the Polar Verity Sense Optical Armband and iPhone Accelerometer for Heart Rate Variability Assessment (opens in a new tab)

  16. Evaluation Of Heart Rate Variability And Cardiovascular Regulation To In-Flight Workload And Thermal Stress

    … timing intervals were identified using Seismocardiography and blood pressure during prolonged head-down tilt bed rest (HDBR). Building on these metrics, historic EVA heart rate, and metabolic rates were analyzed to develop a regression model providing minute-by-minute workload …

    nodak Repository record for Evaluation Of Heart Rate Variability And Cardiovascular Regulation To In-Flight Workload And Thermal Stress (opens in a new tab)

  17. Improving Non-Exercise Vo2max Prediction: a Meta-Analytic Evaluation, Reliability Framework, and Assessment of Heart Rate Variability As a Predictor

    … activity (PA), resting heart rate (RHR), and seismocardiography (SCG) among others, while body weight (BW), body composition, and sex-specific variables were associated with increased error. Chapter 2: A reliability investigation in 42 healthy adults determined that lnRMSSD and lnSDNN required …

    alabama Repository record for Improving Non-Exercise Vo2max Prediction: a Meta-Analytic Evaluation, Reliability Framework, and Assessment of Heart Rate Variability As a Predictor (opens in a new tab)

  18. Processing and learning of cardiac signals: Application to heart failure

    … are called ballistocardiography (BCG) and seismocardiography (SCG). BCG and SCG measure the whole-body reaction forces and local chest vibrations in response to cardiac ejection of the blood from the heart, respectively. The goal of this thesis is to develop effective processing and …

    gatech Repository record for Processing and learning of cardiac signals: Application to heart failure (opens in a new tab)

  19. Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF)

    … attached the sensor on human chest to measure seismocardiography (SCG), which reflects chest vibration associated with heartbeats. The SCG measured by our PVDF sensor was comparable with conventional accelerometers, but PVDF sensor was much softer and imperceptible to wear. To optimize the SCG …

    texas Repository record for Flexible and stretchable piezoelectric bio-integrated sensors and energy harvesters based on polyvinylidene fluoride (PVDF) (opens in a new tab)

  20. On the assessment of cardiomechanical function via wearable sensing systems: harnessing population-level patterns and dynamics for robust physiological monitoring

    The objective of this research is to provide a mathematical and conceptual foundation for the processing and analysis of cardiomechanical signals. We begin by exploring a potential clinical application of this technology, using a multi-modal wearable system to accurately track the progression …

    gatech Repository record for On the assessment of cardiomechanical function via wearable sensing systems: harnessing population-level patterns and dynamics for robust physiological monitoring (opens in a new tab)

Page 1 of 2