Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"self-tapping screws"”.

  1. Parallel-to-Grain Withdrawal Resistance of Structural Self-Tapping Screws in Canadian Timber

    … thesis investigates the withdrawal capacity of self-tapping screws (STS) inserted parallel-to-grain. An experimental study was conducted with 100 screws tested in total. The experimental program includes two main test series. First, withdrawal testing was conducted on screws with a diameter of …

    queens Repository record for Parallel-to-Grain Withdrawal Resistance of Structural Self-Tapping Screws in Canadian Timber (opens in a new tab)

  2. Experimental investigations of shear connections with self-tapping-screws for cross-laminated-timber panels

    … (CLT), and wood connection solutions such as Self-tapping Screws (STS), as well as supporting legislation have created new possibilities for the structural application of timber in mid-rise construction. CLT structures and their connections need to be designed for appropriate capacity, …

    ubc Repository record for Experimental investigations of shear connections with self-tapping-screws for cross-laminated-timber panels (opens in a new tab) Download PDF for Experimental investigations of shear connections with self-tapping-screws for cross-laminated-timber panels (opens in a new tab)

  3. Behaviour of Timber-Steel Connections With Slotted-In Plates and Steel Dowels Reinforced With Self-Tapping Screws

    … were tested with and without reinforcing screws under parallel-to-grain monotonic and cyclic loads. Screws changed the failure mode of the connection, improving ductility and energy dissipation capacity by up to 3.6 and 3.5 times respectively from unreinforced specimens. When tested under …

    queens Repository record for Behaviour of Timber-Steel Connections With Slotted-In Plates and Steel Dowels Reinforced With Self-Tapping Screws (opens in a new tab)

  4. Cyclic Testing of Pre-engineered Beam-Hanger Connections & Reinforcement of Holes in Glulam Beams Using Self-tapping Screws

    … the reinforcement of holes in glulam beams using self-tapping screws. Chapter 3 describes laboratory testing of the Megant 430x150x50 beam-hanger connector under applied interstorey drift deflections based on a modified version of the CUREE loading protocol. The performance of the Megant …

    queens Repository record for Cyclic Testing of Pre-engineered Beam-Hanger Connections & Reinforcement of Holes in Glulam Beams Using Self-tapping Screws (opens in a new tab)

  5. Experimental investigation of steel-to-timber joints with inclined self-tapping screws: A parametric study evaluating load-displacement behavior and testing configurations in quasi-static testing

    Detta examensarbete undersöker användningen av lutande självgängande träskruvar i stål/trä-förband och behandlar deras design samt last-deformationsbeteende genom en experimentell undersökning och en litteraturstudie.Litteraturstudien ger en förståelse för dimensioneringen och beteendet hos …

    chalmers Repository record for Experimental investigation of steel-to-timber joints with inclined self-tapping screws: A parametric study evaluating load-displacement behavior and testing configurations in quasi-static testing (opens in a new tab)

  6. Performance Criteria for Knee-Brace Timber Frames with Mortise and Tenon Joints

    … explore rehabilitation of a damaged member using self-tapping screws. Three damage states for were identified: peg shear, tenon tearout, and post or beam splitting. Self-tapping screws were able to restore the strength of the 2-peg timber frame with the damaged beam, but not the stiffness of the …

    byu Repository record for Performance Criteria for Knee-Brace Timber Frames with Mortise and Tenon Joints (opens in a new tab) Download PDF for Performance Criteria for Knee-Brace Timber Frames with Mortise and Tenon Joints (opens in a new tab)

  7. Seismic Performance of Bolted Glulam Timber Brace Connections with Internal Steel Plates

    … the connections and brace assemblies. The use of self-tapping screws as perpendicular-to-grain reinforcement to prevent splitting and enhance brace ductility was also investigated. The results of the experimental study showed that both end connections in a brace can experience larger plastic …

    queens Repository record for Seismic Performance of Bolted Glulam Timber Brace Connections with Internal Steel Plates (opens in a new tab)

  8. Development of an Innovative Hybrid Timber-Steel Moment-Resisting Frame for Seismic-Resistant Heavy Timber Structures

    … The steel-to-timber connection was made using self-tapping screws. By localizing all inelastic behaviour to a single ductile component, design with high seismic force reduction factors becomes justifiable. Four connections were tested; a majority of the plastic rotation was localized to the …

    carleton Repository record for Development of an Innovative Hybrid Timber-Steel Moment-Resisting Frame for Seismic-Resistant Heavy Timber Structures (opens in a new tab)

  9. Experimental Study of Shear Resistance and Failure Behavior of Reinforced and Un-reinforced Notched Cross-Laminated Timber Plates

    … with various notches and reinforcement using self-tapping screws (STS) were tested in bending in both major and minor strength directions. Un-notched CLT beams under bending primarily failed in rolling shear in the transverse layers. Notches influenced not only the failure mode but also shear …

    uvic Repository record for Experimental Study of Shear Resistance and Failure Behavior of Reinforced and Un-reinforced Notched Cross-Laminated Timber Plates (opens in a new tab)

  10. Evaluation of deck fasteners functioning as shear connectors for composite steel joists

    … are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 Teks/3 with a 1 1/4 in. stand-off sleeve. 3. 1/4-14 Teks/3 with a 1 3/4 in. stand-off sleeve. 4. 1/4-14 Teks/3 with a 2 1/4 in. stand-off sleeve. 5. 0.150 in. dia. air fired pins. 6. Puddle welds (5/8 …

    vt Repository record for Evaluation of deck fasteners functioning as shear connectors for composite steel joists (opens in a new tab)

  11. Application of Ductile Yield Link in Glulam Moment Connections

    … in the perpendicular-to-grain direction using self-tapping screws. Failure mechanisms were analyzed, and performance characteristics related to the connection's strength, stiffness, and ductility were evaluated. Results indicated that the reinforced specimen exhibited higher strength, …

    vt Repository record for Application of Ductile Yield Link in Glulam Moment Connections (opens in a new tab)

  12. Structural performance of nail-laminated timber-concrete composite floors

    … sizes of truss-plates and two configurations of self-tapping screws installed in small-scale TCC specimens were tested under shear load. The connections’ strength and stiffness were determined to evaluate its performance as TCC shear connectors. Second, four truss-plate configurations were …

    ubc Repository record for Structural performance of nail-laminated timber-concrete composite floors (opens in a new tab) Download PDF for Structural performance of nail-laminated timber-concrete composite floors (opens in a new tab)

  13. Structural performance of rounded dovetail connections

    … community with a new design tool. Finally, self tapping screws as reinforcement have been studied and are shown to significantly improve the structural performance of RDC under vertical shear loading.

    ubc Repository record for Structural performance of rounded dovetail connections (opens in a new tab) Download PDF for Structural performance of rounded dovetail connections (opens in a new tab)

  14. Self-tapping screw assemblies under monotonic and reverse cyclic load

    … the performance of newly evolved structural self-tapping full thread wood screws as a primary fastener in Canadian Douglas-fir glulam and Cross-Laminated-Timber. The screws as primary fasteners were investigated in a commonly used shear connection and a recently developed moment resisting …

    ubc Repository record for Self-tapping screw assemblies under monotonic and reverse cyclic load (opens in a new tab) Download PDF for Self-tapping screw assemblies under monotonic and reverse cyclic load (opens in a new tab)

  15. Investigation of brittle failure in steel-to-CLT self-tapping screw connections

    Self-tapping screws (STSs) are becoming increasingly popular in the mass timber construction industry due to their ease of installation, high load-carrying capacity, and suitability for prefabrication. While the new STS provision in CSA O86-24 covers both ductile and brittle failure modes for …

    uvic Repository record for Investigation of brittle failure in steel-to-CLT self-tapping screw connections (opens in a new tab)

  16. The analysis and behaviour of composite space frames with profiled steel sheet floors

    … The composite action is ensured by aseries of self-tapping screws. The experimental work is based on two-unit spaceframe specimens. Each specimen represents two adjacentunits with their top chord member which carries thehighest compressive axial load in the real structure.Each unit is tested in …

    salford Download PDF for The analysis and behaviour of composite space frames with profiled steel sheet floors (opens in a new tab)

  17. Characterization of the seismic behaviour of traditional timber frame walls

    … retrofitting techniques were adopted, such as self-tapping screws and glass fibre sheets, to overcome some limitations found during the in-plane tests on the walls. From the experimental results, an analytical hysteretic model was derived, based on the modification of existing models and …

    minho-thes Repository record for Characterization of the seismic behaviour of traditional timber frame walls (opens in a new tab)

  18. Flexural Strength and Behavior of Timber-Concrete Composite Floors with Hexagonally Headed Self-Tapping Screw Shear Connectors

    … to a concrete top layer using hexagonally headed self-tapping screw shear connectors. To accomplish the objective, coupon specimens and full-scale TCC floor panels were tested, and a finite element modelling approach was developed. The coupon tests were used to determine the stiffness of the shear …

    byu Repository record for Flexural Strength and Behavior of Timber-Concrete Composite Floors with Hexagonally Headed Self-Tapping Screw Shear Connectors (opens in a new tab) Download PDF for Flexural Strength and Behavior of Timber-Concrete Composite Floors with Hexagonally Headed Self-Tapping Screw Shear Connectors (opens in a new tab)

  19. Edge connection technology for cross laminated timber (CLT) floor slabs promoting two-way action

    … to the underside of the panel edges with self-tapping screws are investigated, with experimental results showing promise to maintain a high level of stiffness. This connection system was placed in the maximum moment location of the minor span - attaining a connected span modulus of …

    ubc Repository record for Edge connection technology for cross laminated timber (CLT) floor slabs promoting two-way action (opens in a new tab) Download PDF for Edge connection technology for cross laminated timber (CLT) floor slabs promoting two-way action (opens in a new tab)

Page 1 of 2