Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 77 for “"semiconductor detectors"”.
-
Study of semiconductor detectors for scanning electron microscope.
This thesis is concerned with semiconductor radiation detectors for the detection of back-scattered and secondary electrons in a scanning electron microscopes. The work consists of analysing, both theoretically and experimentally, Si p-n junction cells and Au-Si thin film contacts as regards their …
-
Thin-Film Semiconductor Detectors for 10.6 Microns Radiation
Made available in DSpace on 2014-12-12T20:54:20Z (GMT). No. of bitstreams: 1 7607023.pdf: 4583930 bytes, checksum: c9bcb9d18a0d8188b9ebceaa1295affa (MD5) Previous issue date: 1975
-
Device Engineering and Defect Characterization of Wide-Bandgap Semiconductor Detectors
… characterization of next-generation wide-bandgap semiconductor radiation detectors, specifically focusing on cadmium zinc telluride selenide (CdZnTeSe or CZTS) single crystal, 4H-silicon carbide (4H-SiC) epitaxial layer, and metal-oxide-semiconductor (MOS) 4H-SiC architectures. The research …
-
Evaluation of room-temperature semiconductor detectors for ultrahigh resolution pet imaging
The evaluation of a room-temperature semiconductor detector for ultrahigh resolution positron emission tomography (PET) imaging is presented. The approach is based on the use of a CdTe semiconductor detector. The detector is a 2mm thick cadmium telluride (CdTe) detector with a pixel pitch of 350μm …
-
Hybrid Semiconductor Detectors for High Spatial Resolution Phase-contrast X-ray Imaging
… low detection efficiency) scintillator-based detectors. Thus, imaging throughput is limited, and the absorbed dose in the sample can be unacceptable for radiation sensitive life science and biomedical applications. This work develops hybrid amorphous selenium and complementary …
-
Characterization of p-type silicon semiconductor detectors for use in in vivo dosimetry
… and/or the results of others using similar detectors. Variations in excess of +/-12 % were observed in high-energy wedged fields over the source-to-surface distances investigated. Reductions in local dose directly behind the diode due to electron shielding ranged from 8 to 12%. Entrance and …
-
Design and Fabrication of High-Resolution Epitaxial 4H-Sic Metal Insulator Semiconductor Detectors
… diodes (SBDs) have emerged as reliable radiation detectors for harsh environments. However, the utilization of thicker epitaxial layer devices encounters challenges due to the minimum achievable doping concentration in 4H-SiC epitaxial layers, necessitating higher bias voltages for full depletion …
-
Evaluation of radiation field properties with pixel semiconductor detectors operating in particle tracking mode
The usage of radiation detectors covers a wide range of applications from basic research towards industry or medicine. Continuous technological progress in electronic fabrication processes with help of the sophisticated data analysis methods now allows faster extraction of more complex information …
-
Investigations on CdZnTe-Semiconductor-Detectors for the Search of the Neutrinoless Double Beta Decay
… semiconducting Cadmium-Zinc- Telluride-detectors (CZT). The detectors are made of elements containing several isotopes that decay via double beta decay (ββ-decay). In such a con- figuration the detector itself becomes the source of the decay and, hence, the efficiency for the detection …
-
Multi-pixel charge sharing energy reconstruction (MCSER) algorithm with application in small-pixel semiconductor detectors
Small-pixel CdTe/CZT semiconductor detectors have shown great potential in medical imaging. However, most of current CZT detectors used in medical imaging applications still suffer serious performance degradation partially due to incomplete charge-collection. In this paper, we discuss a multi-pixel …
-
Coherent Elastic Neutrino Nucleus Scatter Response of Semiconductor Detectors to Nuclear Reactor Antineutrinos and Safeguards Applications
In this work, semiconductor CEνNS detector response to reactor antineutrinos is studied. In particular, pulse height distributions and reaction rates are used for nonproliferation and power-monitoring analysis of a research and commercial reactor. The antineutrino spectrum of ²³⁵U, ²³⁸U, ²³⁹Pu, and …
-
Hybrid pixel-waveform semiconductor detectors: novel detector readout for semiconductor pet imaging of small animal neurodegenerative models
… of small pixel hybrid pixel-waveform (HPWF) CdTe detectors for PET by experimentally evaluating common performance criteria such as timing resolution, energy resolution, and spatial resolution with efforts aimed at deconstructing the performance limitations as a PET detector module intended for …
-
Characterization of semiconductor detectors and test beams with high-rate telescopes for the Tracker upgrade of the CMS experiment
… capabilities and will be composed of two sub-detectors: a Pixel vertex detector occupying the inner region and an Outer Tracker (OT) consisting of microstrip modules. The wafers of all the microstrip prototype p-type silicon sensors which were studied in the framework of the CMS Phase-2 …
-
Results from a 3.1 kg day Target Exposure with Skipper CCDs from DAMIC at SNOLAB and other Beyond the Standard Model Searches with Semiconductor Detectors
… target with an 11 kg days exposure from CCD detectors in the DAMIC at SNOLAB experiment. We also observed an unexplained excess of $17.1\pm6.7$ bulk events with exponential decay length of $67 \pm 37 \ \rm eV_{ee}$ above our background model. To investigate, we deployed skipper CCDs with …
-
Physics for particle detectors and particle detectors for physics: Timing performance of semiconductor detectors with internal gain and constraints on high-scale interactions of the Higgs boson
… physics governs the operation of particle detectors, limits their performance, and guides the development of novel instrumentation. To formalise these aspects, classical electrodynamics is used to derive a general description of the formation of electrical signals in detectors, and ideas …
-
Physics Effects in Single-Photon Emission Computed Technology (SPECT) Detectors
… to excellent energy and spatial resolution. Semiconductor detectors are an emerging technology that have three of these ideal attributes: high stopping power, excellent energy and spatial resolutions. Traditional semiconductor detectors comprise a high-Z crystalline material sandwiched by two …
-
Photoproduction of pi�� mesons from He3 with 340 MeV bremsstrahlung
… The recoil nuclei were observed with silicon semiconductor detectors. At least one gamma ray from the pion decay was detected with a lead glass Cherenkov counter. A coincidence between a semiconductor detector and the Cherenkov counter triggered an oscilloscope on which all pulses were then …
-
Gryno germanio gama detektoriaus efektyvumo kalibravimas taškinio ir tūrinio šaltinio atvejais naudojantis GEANT4 programa /
… detector efficiency. This paper discusses semiconductor detectors and their working principles. It also discusses gamma radiation interaction with matter. Furthermore, there is analysis of gamma spectrometer, its working principles and characteristics. Using GEANT4 program virtual detector …
-
Development of GaAs Detectors for Ionising Radiation
… an account of the development of particle detectors made on gallium arsenide semiconductor material. The state of the art in semiconductor detectors is reviewed and likely requirements for the future at LHC outlined. Fabrication of devices is described, as is their characterisation and …
Page 1 of 4