Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 25 for “"sensor function"”.
-
Exception handling for intelligent sensor function
Includes bibliographical references (pages 105-107).
-
Structural Characterization of the C-terminus of the Cochlear Motor Protein Prestin: Intrinsic Disorder Linked to Voltage Sensor Function
… cochlea have motile properties that support this function. The motor protein called prestin resides in the lateral wall of the OHCs. Prestin undergoes voltage-dependent conformational changes, which correlates to the movement of charge through the membrane or non-linear capacitance (NLC). This …
-
A Novel Biostable 3D Porous Collagen Scaffold for Implantable Biosensor
… Despite of development of implantable glucose sensors in long periods, none of the biosensors are capable of continuously monitoring glucose levels during long-term implantation reliably. Progressive loss of sensor function occurs due in part to biofouling and to the consequences of a foreign …
-
Designs and Applications of Surface Acoustic Wave Sensors for Biological and Chemical Sensing and Sample Handling
Acoustic wave sensors have proven useful in many fields as primarily mass sensitive devices capable of responding to small environmental perturbations. The focus of this dissertation is the development of a new type of surface acoustic wave device with application to material property measurement, …
-
Sensor failure detection through introspection
… and mapping (SLAM). SLAM uses a robot's sensors to generate a map of the area while maintaining its current position within that map. SLAM research is built upon the assumption that all of the sensors are working correctly. Since field conditions are likely to cause erratic sensor …
-
The Effects of Implant-Associated Tissue Reactions on Implantable Glucose Sensor Performance
… and treatment of diabetes, implantable sensors that continuously monitor glucose levels have become popular alternatives to patient-administered finger prick measurements of blood glucose. However, following implantation, the performance of these implants suffers from inaccurate and …
-
Dynamic Translation of Drone View to Vehicle View for Autonomous Driving
… presenting significant risk in the form of sensor damage. Since these autonomy algorithms rely on sensor information to navigate their environment, any threat to sensor functionality negatively impacts the reliability of the system. As a potential solution, I propose Dynamic Diffusion-based …
-
Investigation of a flexible printed circuit board MEMS electrostatic field sensor
… variation on a previous MEMS electrostatic field sensor by the application of a new material and fabrication method. Electrostatic field sensors are required that can operate in industrial or outdoor environments where they are subject to damage and contamination. Current MEMS electrostatic field …
-
Structure study of a plant dual-affinity transceptor, CHL1
… which belongs to the low affinity family, functions as a dual-affinity nitrate transporter and sensor, whose high- and low-affinity states are switched upon phosphorylation of a key residue Thr101. However, the following two questions remain unknown: 1) What is the structural mechanism …
-
Fluorescence photophysics, characterisation and application of labelled glucose/galactose binding protein
… of diabetes mellitus. One promising glucose sensor is bacterially-derived glucose binding protein (GBP). In this project, the modified triple mutant H152C/A213R/L238S-GBP (mGBP) was investigated for viability as a functioning glucose sensor. Labelling the protein with the …
-
Molecular Determinants of Synaptic Vesicle Exocytosis and Endocytosis Coupling
… is essential for maintaining normal synaptic function. The reuse of vesicles maintains the size of the presynaptic terminal and ensures the availability of synaptic vesicles for subsequent exocytosis. The coupling of exocytosis and endocytosis allows for continued rapid synaptic transmission; …
-
Soft capacitive force sensing skin : characterization, operation on a curved surface, and increased force range
… and stretchable combined pressure and shear sensor. The conductivity investigation was successful in reducing the resistance of flexible conductive elements by an order of magnitude, to approximately 1.8 kΩ. The two sensor development branches are aimed at creating a sensor that better …
-
Adipose Stem Cells Improve the Foreign Body Response
… at 4 and 8 weeks. Quantification of glucose sensor response following ASC attachment for 1 week found no measurable significant differences in function.</p><p> The bioluminescence technique, which quantifies the tissue glucose concentration around the implant at the moment of freezing, was …
-
Biocompatibility of subcutaneous implanted glucose sensors: Working toward modeling the sensor/tissue interface
… The development of a reliable glucose sensor for use in these systems has been hampered by anomalies in in vivo sensor performance due to the inflammatory response. Investigation of the biocompatibility of implanted glucose sensors with respect to the inflammatory processes was …
-
Knowledge integration strategies in defect diagnosis
… where the estimated cause variable resembles a sensor function, and the true cause variable represents the target function. Therefore, the problem becomes a mapping of one function to the other. Several learning algorithms are created based on these developments. Then the algorithms are …
-
Proposed improvement of system status displays for the F/A-18E/F Super Hornet aircraft
… These aircraft utilize complex weapon and sensor suites, though specific weapon and sensor requirements vary widely from mission to mission.</p> <p>The weapon and sensor suites of modern, multi-role tactical fighter aircraft consist of both offensive and defensive systems. The status of …
-
Finite Element Modeling of Dermally-implanted Enzymatic Microparticle Glucose Sensors
… polyelectrolyte multilayer nanofilms. In such sensors, a phosphorescent oxygen indicator is also co-encapsulated with the enzyme inside so that when glucose is present, glucose oxidase within the sensor reduces the local oxygen levels, causing a corresponding change in the luminescence …
-
Biotextilogy: Applications for research and development
… gradients, e.g. to oedematous limbs (actuator function) or changing of its own form when strained by neighboring tissues (sensor function). This thesis also applies biotextilogy and MADAME to test textiles created to mimic the natural patterns of collagen and elastin in periosteum. First the …
-
Creating more effective functional materials: altering the electronics of conducting metallopolymers for different applications.
… attractive electronic properties for use in sensors, photoelectronic devices, catalysts, and other applications. Modification of the conducting polymer backbone, through chemical or electrochemical methods, enables control of catalytic, electronic, and optical properties of the metal via …
-
Interfacial Electrochemistry and Surface Characterization: Hydrogen Terminated Silicon, Electrolessly Deposited Palladium & Platinum on Pyrolyzed Photoresist Films and Electrodeposited Copper on Iridium
… as the sensing electrode for a potentiometric sensor for ultra-trace amounts of metal contaminants. Previous studies show the use of this potentiometric electrode sensor in hydrofluoric acid solution. This work is able to shows sensor function in ultra-pure water media without the need for …
Page 1 of 2