Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 109 for “"service load"”.

  1. Service load cracking behavior of reinforced concrete bridge decks

    … moment regions of continuous girders under service loading and to develop suitable guidelines for their use in such applications. A major focus of the research is the influence of the reinforcing details on the control of deck crack width. Four concrete bridges were monitored during their …

    texas Repository record for Service load cracking behavior of reinforced concrete bridge decks (opens in a new tab)

  2. Prediction of service load of concrete structures after cracking using ultrasonic technique

    … a new approach to assess their remaining service lives. A novel ultrasonic technique is utilized to detect crack propagation in notched beams of mortar, plain concrete and reinforced concrete. The study showed that crack growth and microcrack zone in cementitious composites can be …

    njit Repository record for Prediction of service load of concrete structures after cracking using ultrasonic technique (opens in a new tab)

  3. Short and Long-Term behaviour of GFRP-FRC Structural Members Under Sustained Service Load

    … of FRP reinforced concrete members under serviceability conditions with a particular focus on the avoidance of excessive deformations and crack widths. Moreover, the introduction of fibres in fibre-reinforced concrete (FRC) improves the flexural toughness and cracking capacity of the …

    whiterose Download PDF for Short and Long-Term behaviour of GFRP-FRC Structural Members Under Sustained Service Load (opens in a new tab)

  4. Structural Condition Assessment and Service Load Performance of Deteriorated Prestressed Concrete Deck Beam Bridges

    … to conclude that a deck beam is being overloaded were are also studied. Several conclusions were found. Cracking of the longitudinal joint has little effect on the stiffness of the bridge if the transverse rod is snug. The presence of a snug transverse tie rod increases the strength of the …

    uiuc Repository record for Structural Condition Assessment and Service Load Performance of Deteriorated Prestressed Concrete Deck Beam Bridges (opens in a new tab)

  5. Experiments, Analysis and Design Models for Slab on Prestressed Concrete Girder Bridge Structures

    … its structural performance in general, and load distribution behavior in particular, comprehensive static and dynamic tests are performed on an in-service spread slab beam bridge, the US 69 Bridge located in Denison, Texas. Different computational techniques including the historic grillage …

    tamu Repository record for Experiments, Analysis and Design Models for Slab on Prestressed Concrete Girder Bridge Structures (opens in a new tab)

  6. Deformation of partially prestressed concrete beams under service loads.

    … concrete beams in which 50 percent of the service load was sustained for a period of up to 46 days during which time the load was increased to the full service load up to seven times in intermittent short-term cycles. One cycle of short-term loading was carried out at intervals of about …

    whiterose Download PDF for Deformation of partially prestressed concrete beams under service loads. (opens in a new tab)

  7. Fatigue Behavior of Concrete Bridge Decks Cast on GFRP Stay-in-Place Structural Forms and Static Performance of GFRP-Reinforced Deck Overhangs

    … All the decks survived 3M cycles at 123kN service load of CL625 CHBDC design truck. The bonded flat-ribbed-form deck survived an additional 2M cycles at a higher load simulating a larger girder spacing of 8ft. Stiffness degradations were 9-33% with more reduction in the unbonded specimens. …

    queens Repository record for Fatigue Behavior of Concrete Bridge Decks Cast on GFRP Stay-in-Place Structural Forms and Static Performance of GFRP-Reinforced Deck Overhangs (opens in a new tab)

  8. Construction and testing of a low volume road bridge alternative: Steel-beam precast units

    … contractor. The final division involved the service load testing of the units at different stages of the construction process. Based upon the construction and service load testing, the steel-beam precast unit bridge was successfully shown to be a viable low volume road bridge alternative. The …

    iastate Repository record for Construction and testing of a low volume road bridge alternative: Steel-beam precast units (opens in a new tab)

  9. K-12 STEM Educators and the Inclusive Classroom

    … teachers to provide high-quality, accommodative service and equitable educational opportunities in an increasingly STEM-infused society. Professional development associated with teaching students with disabilities and LEP is critical to inform in-service STEM teachers with these students' …

    vt Repository record for K-12 STEM Educators and the Inclusive Classroom (opens in a new tab)

  10. EFFECTIVE WIDTH AND ULTIMATE STRENGTH OF CONTINUOUS COMPOSITE BEAMS.

    … mid-span and supports, at yield and at ultimate loads. New design equations have been developed to calculate the ultimate strength of a composite section in both positive and negative moment regions. Ductility and deflection characteristics have been studied and equations are proposed to …

    arizona-thes Repository record for EFFECTIVE WIDTH AND ULTIMATE STRENGTH OF CONTINUOUS COMPOSITE BEAMS. (opens in a new tab)

  11. Full scale testing of corrugated metal culvert pipe rehabilitated with shotcrete liner

    … statically under simulated single wheel pair pad loading representing the geometry of CL-625 ONT dual tire truck footprint. The performance of the rehabilitated test culvert pipe was monitored during backfilling and during live load testing. Then, the rehabilitated test culvert pipe was loaded to …

    manitoba Repository record for Full scale testing of corrugated metal culvert pipe rehabilitated with shotcrete liner (opens in a new tab)

  12. Strength and Behavior of Rural Short-Span Precast Concrete Bridges in South Carolina

    … (SCDOT) is currently in the process of load rating every bridge in their inventory. Two types of short-span precast concrete bridges built around the 1960s are prevalent throughout the state, exhibiting different levels of deterioration. In order to better understand how these bridge …

    clemson Repository record for Strength and Behavior of Rural Short-Span Precast Concrete Bridges in South Carolina (opens in a new tab)

  13. Behaviour and Design of Reinforced Concrete Pipes

    … with Wall C) were tested under single wheel pair loading at burial depths of 1.2, 0.6 and 0.3 m. The test pipes did not crack at the applied service load of 110 kN and did not pass the crack width limit until between 2.5 and 4 times the service load. A 0.6 m 100-D pipe was also tested under …

    queens Repository record for Behaviour and Design of Reinforced Concrete Pipes (opens in a new tab)

  14. Punching shear strength of steel fibre reinforced lightweight concrete slabs.

    … is the punching shear failure at over loads. Such failures are sudden and catastrophic, and are undesirable since they do not allow an overall yield mechanism to develop. Fibre reinforcement restrains cracking, and increases the tensile strength of concrete and bond resistance of steel …

    whiterose Download PDF for Punching shear strength of steel fibre reinforced lightweight concrete slabs. (opens in a new tab)

  15. Flexural Behavior of Composite FRP-Concrete-Steel Poles

    … of these poles was evaluated in terms of load-deflection curves, ultimate moment capacities, and load-strain response. The previously mentioned terms were evaluated at 1st service load (25% of predicted ultimate load), 2nd service load (50% of predicted ultimate load), and ultimate load. …

    uab Repository record for Flexural Behavior of Composite FRP-Concrete-Steel Poles (opens in a new tab)

  16. GFRP-Reinforced Concrete Guideway Beams for Monorail Applications

    … beam to better predict behaviour beyond typical service load levels. A total of 450 test passes of a two-car monorail train were observed over the two instrumented beams on the track. These passes were performed at vehicle loads ranging from fully unloaded for the first testing phase, up to the …

    queens Repository record for GFRP-Reinforced Concrete Guideway Beams for Monorail Applications (opens in a new tab)

  17. Testing and Analysis of a Fiber-Reinforced Polymer (FRP) Bridge Deck

    … edges. Extensive experimental study under service, strength and fatigue loads in a full-scale two-bay mock-up test and a field test was performed. Test results showed that no crack initiated in the joints under service load and no significant change in stiffness or strength of the joint …

    vt Repository record for Testing and Analysis of a Fiber-Reinforced Polymer (FRP) Bridge Deck (opens in a new tab)

  18. Structural response of Light weight concrete beams in flexure

    … capacity, but results in higher deflection at service load and lead to brittle failure compared to NWC beams. The provisions contained in four major codes of practice were assessed with the results from 64 pull-out tests, 30 direct-tensions tests and 28 tests on beams in flexure. Based on the …

    nus Repository record for Structural response of Light weight concrete beams in flexure (opens in a new tab) Download file for Structural response of Light weight concrete beams in flexure (opens in a new tab)

  19. Structural Performance and Economic Impact of Skewed Reinforcing in Inverted-T Bridge Caps

    … the analytical results, the stiffness at the service load, the maximum crack width at the service load, and the ultimate strength of the specimens are investigated and compared. Following some basic assumptions on materials and construction time, design and construction costs of the …

    houston Repository record for Structural Performance and Economic Impact of Skewed Reinforcing in Inverted-T Bridge Caps (opens in a new tab)

  20. Load measurement of in-service marine structures to influence their design.

    Current methods to predict hydrodynamic loads rely either on oversimplified and semiempirical methods or the use of numerical simulation and analysis techniques such as Finite Element Analysis (FEA) or Boundary Element Analysis (BEA). These methods are conservative which results in the over-design …

    bournemouth Download PDF for Load measurement of in-service marine structures to influence their design. (opens in a new tab)

Page 1 of 6