Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 66 for “"shaped holes"”
-
Study Of Film Cooling Effectiveness: Conical, Trenched And Asymmetrical Shaped Holes
… turbulated channels, and rows of film cooling holes, all of which over the years have become progressively more complex. This costly, but necessary complexity is a result of the industry's push to run engines at increasingly higher turbine inlet temperatures. Higher temperatures mean higher …
-
Effect of inlet hole geometry on surface film cooling effectiveness from compound angle, shaped holes.
The gas turbine engine operates at temperatures that far exceed the melting point of the metals from which they are made. Cooling air from the high pressure compressor must be used to cool the components in the hot sections of the turbine engines. Coolant must be used as effectively as possible in …
-
Experimental study of film cooling and heat transfer on a gas turbine vane with shaped holes
… in order to investigate the heat transfer of shaped holes over a gas turbine stator. An in-situ calibration technique has been developed to obtain the film cooling performance without disturbing the aerodynamic flow around the vane surface. Subsequently, the cooling performance of two types of …
-
The effect of channel parameters on the adiabatic film cooling effectiveness of shaped holes in crossflow
… information in the literature on the behavior of shaped film cooling holes fed by crossflow and even less information on the effect of crossflow parameters on film cooling performance. Here, two scaled film cooling models were used to independently vary the crossflow Reynolds numbers in the range …
-
Film Cooling with Forward and Backward Injection for Cylindrical and Fan-shaped Holes Using PSP Measurement Technique
… used in this study: simple angled cylindrical holes and fan-shaped holes, and compound angled (β = 45°) cylindrical holes and fan-shaped holes. Additional four film-hole geometries with backward injection were tested by reversing the injection direction from forward to backward to the …
-
CFD Validation of Flat Plate Film Cooling of Cylindrical and Shaped Holes Using RANS and LES Computational Models
… One such technique is film cooling using holes wherein the air from the compressor is bled and fed into the film cooling holes.A part of this computational study on film cooling involves the numerical validation of the LES computational technique with Dynamic Smagorinsky model to predict …
-
Investigation of inlet and diffuser geometry modifications on film cooling performance of additively manufactured shaped holes in crossflow
Film cooling holes permit gas turbine firing temperatures to significantly exceed the melting point of the constituent materials by venting compressor bleed air along the surface of a component forming a buffer between the wall and surrounding gas. A film cooling hole is a passive geometric feature …
-
The influence of hole geometry and metering length on flm cooling effectiveness of laid-back fan-shaped holes in compressible high-speed flow conditions
… the film cooling performance of laid-back fan-shaped holes operated at realistic engine Mach numbers, using a flat plate wind tunnel configuration. Also included is an expanded analysis for a linear cascade test section. As modern gas turbine engines operate under extreme thermal loads, …
-
Experimental investigation of film cooling effectiveness on gas turbine blades
… film cooling, the effectiveness from axial shaped holes and compound angle shaped holes were examined. Results showed that the compound angle shaped holes offer better film effectiveness than the axial shaped holes. The upstream stationary wakes have detrimental effect on film effectiveness …
-
Flat Plate Film Cooling with Linear and Curved Round-to-Diffusion Shaped Slots Using PSP Measurement Technique
… obtained agreed with the general trend of shaped holes. It is interesting to observe that slot shaped exit hole is still a better option than annulus shaped holes. Slot shaped exit hole with projectile trajectory resulted in improved effectiveness with 30-40% increase in span wise …
-
Experimental Investigation of Film Cooling Effectiveness on Gas Turbine Blades
… are two test models: seven and three-row of film holes for simulating vane and blade, respectively. Four film holes’ configurations are used for both models: radial angle cylindrical holes, compound angle cylindrical holes, radial angle shaped holes, and compound angle shaped holes. Density ratios …
-
Experimental and numerical investigation of film cooling jet on a flat plate wind tunnel
… geometries include a row of three cylindrical holes and a row of three fan-shaped holes with an inclination of 30 degrees with respect to the flat plate. Tests have been carried out at low speed and low inlet turbulence intensity level, with blowing ratios varied in the range of 0.5–1.5, and …
-
Variable incidence angle film cooling experiments on a scaled up turbine airfoil model
… of two highly realistic airfoil models with shaped holes at varying incidence angles. This was accomplished through application of the appropriate aerodynamic and heat transfer scaling parameters for all measurements. Among other results, it was found that the shaped holes at the stagnation …
-
Parametric Study of Gas Turbine Film-Cooling
… film-cooling test shows that the compound angle shaped holes offer better film effectiveness than the axial shaped holes. Greater coolant-to-mainstream density ratio prevents coolant to lift-off. Higher freestream turbulence causes effectiveness to drop everywhere except in the region downstream …
-
A Detailed Study of Fan-Shaped Film-Cooling for a Nozzle Guide Vane for an Industrial Gas Turbine
… benefit from the coolant flow that is used. Fan-shaped holes offer this opportunity, reducing the normal jet momentum and spreading the coolant in the lateral direction providing better surface coverage. The main drawback of fan-shaped cooling holes is the added manufacturing cost from the need …
-
Evaluation of film cooling superposition method on the suction side of a blade model
… studies of the performance of a single row of holes. Typically, blades and vanes in gas turbine engines have multiple rows of holes that interact. Consequently, there is a need to develop techniques to predict film cooling performance with multiple rows of holes. One of the method is to …
-
Performance of a Showerhead and Shaped Hole Film Cooled Vane at High Freestream Turbulence and Transonic Conditions
… to further characterize the performance of shaped hole film cooling by taking measurements on a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a 1st stage NGV. Tests were performed at engine …
-
Pulsed Eddy Current Inspection of Broach Support Plates in Steam Generators
… Broach Support Plates (BSPs) that have trefoil shaped holes, which prevent excessive tube vibrations, while allowing water to easily flow through the support structures. A number of degradation modes occur in SGs, such as SG tube fretting, cracking or denting, requiring periodic inspection. …
-
Experimental and Numerical Investigation of Turbine Blade Leading Edge Heat Transfer with Jet Impingement and Film Cooling
… blade leading edge profile on film cooling with shaped holes, (2) internal heat transfer of film-cooled leading edge model with normal and tangential impinging jets, (3) overall effectiveness of film-cooled leading edge model with normal and tangential impinging jets. The results provide baseline …
Page 1 of 4