Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 20 of 168 for “"shear connectors"”
-
Testing of demountable shear connectors
… from the steel I-section if welded headed stud connectors are used. A new demountable shear connector was developed as a part of this thesis to promote sustainable composite construction. The connector is composed of two angle sections and a high-strength bolt. The proposed system has been …
-
Behaviour of channel shear connectors : push-out tests
… the testing of push-out specimens with channel shear connectors. The test program involved the testing of 78 push-out specimens and was aimed at the development of new equations for channel shear connectors embedded in solid concrete slabs and slabs with wide ribbed metal deck oriented parallel …
-
Behaviour of demountable shear connectors in composite structures
… is to evaluate the feasibility of demountable shear connectors as an alternative to welded shear connectors in composite structures through push off tests and composite beam tests. Push off tests were conducted to examine the shear strength, stiffness and ductility of demountable shear …
-
Horizontal Shear Connectors for Precast Prestressed Bridge Decks
… as for new bridge construction. The horizontal shear strength at the interface between the two interconnected elements is of primary importance in order to provide composite action. The strength of the bond between the two precast members should be high enough to prevent any progressive slip …
-
Behavior and Strength of Welded Stud Shear Connectors
The behavior and strength of welded shear studs are subjects of ongoing study. In recent years, research has shown that the American Institute of Steel Construction (AISC) specification equations for shear stud strength are unconservative for studs placed in deck with ribs transverse to the steel …
-
BEHAVIOUR OF SLOTTED AND FLEXIBLE PERFOBOND RIB SHEAR CONNECTORS
The perfobond rib connector is a new type of shear connector, first used in the construction of the Third Caroni bridge in Venezuela. Except for a limited number of proprietary tests conducted in Germany, research on perfobond rib shear connectors has been carried out mainly in Canada. Results of …
-
Push-out and composite beam tests of shear connectors
<p>http://www.worldcat.org/oclc/9414807</p>
-
Tension and Compression Behaviour of Masonry Walls with Shear Connectors
Masonry connectors are used in wythe wall systems to either transfer lateral loads or increase composite behaviour. As future energy code requirements are updated, insulation is increasing which increases the cavity within walls which affects a connector’s behaviour. Due to a lack of masonry …
-
Standoff screws functioning as mechanical shear connectors in composite joists
… standoff screw functioning as a mechanical shear connector are presented. In all tests, the base material, through which the screw was fastened, was fabricated out of back to back angle to simulate the top chord of an open web steel joist. Varied test parameters include: steel deck profile, …
-
Influence of shear connectors on the elastic behaviour of composite girders
The effect of deformable and rigid connectors and influence of connection parameters on the behaviour of composite girders is examined. Both the elastic and plastic behaviour are discussed, but the former one is the main concern. Deformable connectors cause slip in the joint, which results in …
-
On Thermal Bowing of Concrete Sandwich Wall Panels with Flexible Shear Connectors
… concrete layer thickness, panel length, type of shear connector and separation using a commercial finite element analysis software. This study concluded that current design practices either underestimate, in the case of multiplying the classical mechanics values by the reported degree of …
-
Design of shear connectors for precast concrete decks in concrete girder bridges
… effectiveness. These systems require the use of shear connectors between the precast concrete deck panels and the supporting girders to transfer interface shear and achieve composite action. The use of discrete clustered shear connectors is highly preferred in order to simplify panel and girder …
-
Performance of GFRP reinforcement as friction shear connectors in concrete composite elements
… integrity can be maintained only if the friction shear along the joint interface resulted from the gravity load is resisted. The characteristics of the reinforcement crossing the joint interface, concrete strength, and shear plane condition are some of the main factors controlling the integrity of …
-
Evaluation of deck fasteners functioning as shear connectors for composite steel joists
The use of deck fasteners as shear connectors for composite open web steel joists is studied. Results of thirty-six push-off tests are evaluated in terms of strength and behavior. Six types of deck fasteners are considered. They are: 1. #12-24 Teks/5 self-drilling, self-tapping screws. 2. 1/4-14 …
-
Nonlinear fiber modeling of steel-concrete partially composite beams with channel shear connectors
… for the steel-concrete interface. The channel shear connector response used in numerical models was based on the previously obtained experimental response from pushout tests. Accuracy of the numerical models in predicting the response of composite beams with varying degree of composite action …
-
Reliability analysis of studded shear connectors in composite slabs subjected to shear loading
This study investigated the reliability of stud connectors in composite slabs subjected to shear loading, focusing on the adequacy and efficiency of design provisions outlined in four major international codes: SANS 10162-4, EN 1994, AISC 360, and AS/NZS 2327:2017. The analysis evaluated the safety …
-
Behaviour and design of headed stud shear connectors in composite steel-concrete beams
… influenced by the strength and ductility of the shear connectors between the structural steel beam and the concrete slab. The behaviour of the shear connectors is important in understanding the shear force transmitted and the degree of slip which occurs at the interface of the steel and concrete. …
-
Strengthening existing steel bridge girders by the use of post-installed shear connectors
… floor systems by the use of postinstalled shear connectors. Three types of post-installed shear connection methods were investigated. These methods are referred to as the double-nut bolt, the high tension friction grip bolt, and the adhesive anchor. These post-installed shear connectors …
Page 1 of 9