  1. Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems

    … electric machine experiencing winding short-circuit faults of varying severity. The experimental data collected from the faulted machine is from both motoring operation energized by a PWM sensorless ac drive as well as generating operation driven by the test bed dynamometer with a …

    marquette Repository record for Characterization of Stator Winding Short-Circuit Faults in Interior Permanent-Magnet Motor-Drive Systems (opens in a new tab)

  2. CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY

    The stator winding short circuit faults in Brushless Synchronous Generator (BLSG) used for onboard power generation in ships may lead to catastrophic failures and back out. Hence, it is important to develop Condition Monitoring (CM) techniques for the BLSG to improve its reliability and …

    nus Repository record for CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY (opens in a new tab) Download file for CONDITION MONITORING OF MARINE ELECTRICAL GENERATORS FOR IMPROVED MAINTENANCE LEADING TO INCREASED RELIABILITY AND AVAILABILITY (opens in a new tab)

  3. Data analytics applications to fault locations and overcurrent protection devices

    … square (RMS) variations and transients caused by short-circuit faults, transformer energizing, or capacitor switching around the clock, resulting in a large amount of data. Although the collected data contain valuable information about the system, they are often merely stored without any further …

    texas Repository record for Data analytics applications to fault locations and overcurrent protection devices (opens in a new tab)

  4. Fault detection and location in modular trees

    … thesis. The fault set is restricted to stuck-at-faults in the discussion of the fault location problem. Short circuit faults and broken and short circuit faults are considered in the discussion of the fault detection problem. In either the fault detection or location case, detection conditions …

    vt Repository record for Fault detection and location in modular trees (opens in a new tab)

  5. Fault Protection In DC Distribution Systems Via Coordinated Control of Power Supply Converters and Bus Tie Switches

    … and mechanical contactors to rapidly isolate short circuit faults while maintaining continuity of power to loads. This work is important because the increasing performance, higher efficiency, and decreasing cost of electronic power converters have spurred a rediscovery and proliferation of dc …

    south-carolina Repository record for Fault Protection In DC Distribution Systems Via Coordinated Control of Power Supply Converters and Bus Tie Switches (opens in a new tab)

  6. Ανάπτυξη μεθοδολογίας εντοπισμού θέσης σφάλματος βραχυκύκλωσης σε σύγχρονα συστήματα διανομής ηλεκτρικής ενέργειας

    … quality of the system design, the occurrence of faults cannot be completely prevented, nor is it technically or economically justifiable to attempt to eliminate them entirely. Instead, the prompt clearance of faults, followed by the accurate identification of their location, is essential. These …

    greece Repository record for Ανάπτυξη μεθοδολογίας εντοπισμού θέσης σφάλματος βραχυκύκλωσης σε σύγχρονα συστήματα διανομής ηλεκτρικής ενέργειας (opens in a new tab)

  7. Power Electronics- based Photovoltaics Panel Fault Detection using Online Impedance Measurement Technique

    … with C2000 MCU and helps identify hot spot faults and short circuit faults in a 300 W rooftop PV panel. Multiple PV panel faults scenarios such as hot spot faults, short circuit faults, junction box faults, and capacitor faults are investigated to deduct further the effectiveness of the …

    vt Repository record for Power Electronics- based Photovoltaics Panel Fault Detection using Online Impedance Measurement Technique (opens in a new tab)

  8. Incipient fault diagnosis in squirrel-cage induction motors

    … for detecting rotor broken-bars and inter-turn short-circuit faults in induction motors is introduced based on electromagnetic field laws governing the operation and performance of induction machines. The basis of this new method is to monitor the orientation of the axis of the induction …

    marquette Repository record for Incipient fault diagnosis in squirrel-cage induction motors (opens in a new tab)

  9. A Condition Monitoring Vector (CMV) Technique for Poly-Phase Electric Machine Fault Diagnostics

    … for poly-phase induction motor stator inter-tum short-circuit faults is presented. To be more specific, the CMV includes the swing angle, the negative sequence component of motor terminal currents and voltages, as well as the input power of the induction motor. The effectiveness of the CMV is …

    marquette Repository record for A Condition Monitoring Vector (CMV) Technique for Poly-Phase Electric Machine Fault Diagnostics (opens in a new tab)

  10. Modelling, simulation and implementation of a fault tolerant permanent magnet AC motor drive with redundancy.

    … in this thesis and it is concluded that switch short-circuit fault is the most serious fault since it reduces the electromagnetic torque output significantly and generates larger torque ripple in the motor drive due to the presence of large drag torque. Three fault remedial strategies were …

    adelaide Repository record for Modelling, simulation and implementation of a fault tolerant permanent magnet AC motor drive with redundancy. (opens in a new tab)

  11. Experimental analysis of immunity of process equipment to voltage dips

    … power quality (PQ) disturbance mainly caused by short circuit faults. It can cause malfunctioning of sensitive equipment that leads to the disruption of industrial processes, which usually result in substantial financial losses. One way to solve the problems caused by voltage dips is to identify …

    eindhoven Repository record for Experimental analysis of immunity of process equipment to voltage dips (opens in a new tab)

  12. Development of diagnostic techniques and software for a parallel digital signal processing board

    … to create methods for detecting and locating faults in newly produced boards or malfunctioning boards. When new boards arrive from the manufacturer, they must be checked to verify functionality. The complexity of the boards requires an automated verification procedure to check each memory bank …

    ut-knoxville Repository record for Development of diagnostic techniques and software for a parallel digital signal processing board (opens in a new tab)

  13. Synchronous Condensers and Grid-Forming Control for the Integration of Inverter-Based Resources in Weak Grids

    … inertia of SGs, and they do not contribute to short-circuit fault currents as much as SGs do. The lack of strength and inertia increases the risk of instability during contingencies, e.g., short-circuit faults. This dissertation investigates and proposes methodologies to enhance the stability …

    vt Repository record for Synchronous Condensers and Grid-Forming Control for the Integration of Inverter-Based Resources in Weak Grids (opens in a new tab)

  14. Modeling of Inverter-Based Resources for Hardware in the Loop Testing of Protection and Control Schemes

    … nature of fault currents fed by the IBR during short-circuit faults. Misoperation may cause damage to power system equipment and affect the reliability of the power system. This dissertation presents an in-depth investigation into the modeling of IBR in the context of transmission line fault …

    mtu Repository record for Modeling of Inverter-Based Resources for Hardware in the Loop Testing of Protection and Control Schemes (opens in a new tab)

  15. Model-based dynamic relaying for power system protection under uncertainty

    … include concurrent high load demand, changes in circuit topology, equipment outages, and short-circuit faults. With levels of wind and photovoltaic (PV) generation projected to increase in the future, large-scale variable generation also presents an additional point of vulnerability to the …

    texas Repository record for Model-based dynamic relaying for power system protection under uncertainty (opens in a new tab)

  16. Universal Short-Circuit and Open-Circuit Fault Detection for an Inverter

    Short-circuit and open-circuit faults of an inverter’s power device often lead to catastrophic failure of the entire system if not detected and acted upon within a few microseconds, particularly for emerging wide bandgap (WGB) power semiconductors. While a significant amount of research has been …

    clemson Repository record for Universal Short-Circuit and Open-Circuit Fault Detection for an Inverter (opens in a new tab)

  17. Modeling of Power Consumption and Fault Tolerance for Electronic Textiles

    … the physical nature of the e-textile and the faults developed can adversely affect the accuracy of results from the e-textile. Open and short circuit faults can disconnect or drain the battery respectively, affecting both battery life and the performance of the e-textile. This thesis describes …

    vt Repository record for Modeling of Power Consumption and Fault Tolerance for Electronic Textiles (opens in a new tab)

  18. Detection of Inter-turn Winding Fault in Single-phase Transformers Using a Terminal Measurement Based Modeling Technique

    … providing power to the domestic consumers. Any faults in the single-phase transformers leading to power outages or catastrophic power systems failures cause huge loss of capital, property and in some cases even human casualties. Gradual deterioration of the electrical winding insulation …

    uvic Repository record for Detection of Inter-turn Winding Fault in Single-phase Transformers Using a Terminal Measurement Based Modeling Technique (opens in a new tab)

  19. Modeling, Control, and Operation of a Grid-Tied Solar Photovoltaic Inverter in Unbalanced Conditions

    … sequence current contribution during such short- circuit faults. Thus, a proper modeling operation and analysis are required to work out valuable solutions and to understand the unbalance GFL converter systems. In this research, the dissertation carried out the following tasks. In the first …

    usf Repository record for Modeling, Control, and Operation of a Grid-Tied Solar Photovoltaic Inverter in Unbalanced Conditions (opens in a new tab)