Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 11 of 11 for “"short-term frequency stability"”.

  1. Development of a multiphysics model for precision thermal controls of an active hydrogen maser

    The active hydrogen maser atomic frequency standard is widely used in modern radio science astronautics research due to its outstanding short-term frequency stability. Short-term frequency stability is critical to radio science applications because the accuracy and resolution of spacecraft range …

    alabama Repository record for Development of a multiphysics model for precision thermal controls of an active hydrogen maser (opens in a new tab)

  2. Development of micro-fabricated vapour cell technology for compact atomic devices

    … wavelength reference, which demonstrated a frequency tunabilityof ± 60MHz and a short-term frequency stability comparable to conventionalRb wavelength references. Next I fabricated a 6 mm thick micro-fabricated cell,which was capable of sustaining a cold atom sample with active vacuum …

    strathclyde Repository record for Development of micro-fabricated vapour cell technology for compact atomic devices (opens in a new tab)

  3. Oscillator Phase Noise Reduction Using Nonlinear Design Techniques

    Phase noise from radio frequency (RF) oscillators is one of the major limiting factors affecting communication system performance. Phase noise directly effects short-term frequency stability, Bit-Error-Rate (BER), and phase-locked loop adjacent-channel interference. RF oscillator circuits contain …

    vt Repository record for Oscillator Phase Noise Reduction Using Nonlinear Design Techniques (opens in a new tab)

  4. Cryogenic hydrogen maser

    … 660 mK and for densities up to 3 x 1012cm⁻³. The short term frequency stability was measured with the help of two high quality quartz crystal oscillators by the three-cornered-hat method. The observed fractional frequency fluctuations for an averaging time of 1 s were 6.3 ± 3.7 x 10⁻¹⁴, which is …

    ubc Repository record for Cryogenic hydrogen maser (opens in a new tab) Download PDF for Cryogenic hydrogen maser (opens in a new tab)

  5. Slow Light Cavities for Thermal Noise Mitigation in Laser Frequency Stabilization

    Precision laser frequency stabilization is an important part of modern optical metrology, with applications ranging from atomic clocks to fundamental tests of physics. However, the frequency stability of the ultrastable cavities used in these experiments is fundamentally limited by thermal noise in …

    lund Repository record for Slow Light Cavities for Thermal Noise Mitigation in Laser Frequency Stabilization (opens in a new tab) Download PDF for Slow Light Cavities for Thermal Noise Mitigation in Laser Frequency Stabilization (opens in a new tab)

  6. Time and Frequency Transfer in a Coherent Multistatic Radar using a White Rabbit Network

    … radars require accurate and stable time and frequency transfer (TFT) for range and Doppler estimation. TFT techniques based on global navigation satellite systems (GNSS), have been favoured for several reasons, such as enabling node mobility through wireless operation, geospatial referencing, …

    cape-town Repository record for Time and Frequency Transfer in a Coherent Multistatic Radar using a White Rabbit Network (opens in a new tab)

  7. Implementation of Real-Time Software Receiver for Gps or Glonass L1 Signals

    … Peripheral (USRP) with a maximum real sampling frequency of 8MHz of complex samples. The USRP uses interchangeable daughter boards to down-convert and digitize RF signals in the range of DC to 2.9GHz, where each daughterboard covers an overlapping subset of this range. This RF front end was …

    vt Repository record for Implementation of Real-Time Software Receiver for Gps or Glonass L1 Signals (opens in a new tab)

  8. Scalable modeling of future-grids under high penetration of distributed energy resources through multi-timescale T&D co-simulation

    … along with the transmission system for long-term voltage stability margin assessment (VSM). A detailed analysis of net-load unbalance (NLU) impact on VSM was done that also demonstrates the need for T&D co-simulation, especially for cases with high unbalance and high DER penetration in the …

    iastate Repository record for Scalable modeling of future-grids under high penetration of distributed energy resources through multi-timescale T&D co-simulation (opens in a new tab)

  9. Měření stability kmitočtu funkčních generátorů

    … Agilent 33120A. Parametry krátkodobé kmitočtové stability jsou získávány univerzálním čítačem HP53131A.

    brno-tech Repository record for Měření stability kmitočtu funkčních generátorů (opens in a new tab)

  10. Nejistoty nepřímého měření stability kmitočtu funkčních generátorů

    … matematický model pro vyhodnocení krátkodobé stability kmitočtu. Dle sestaveného modelu bylo realizováno měření a vyhodnocení standardních nejistot krátkodobé stability kmitočtu.

    brno-tech Repository record for Nejistoty nepřímého měření stability kmitočtu funkčních generátorů (opens in a new tab)