Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 44 for “"showerhead"”.
-
Showerhead Film Cooling Performance of a Turbine Vane at High Freestream Turbulence in a Transonic Cascade
… number on the film cooling performance of a showerhead film cooled first stage turbine vane at high freestream turbulence (Tu = 16%) and engine representative exit flow conditions. The vane was arranged in a two-dimensional, linear cascade in a heated, transonic, blow-down wind tunnel. The …
-
Performance of a Showerhead and Shaped Hole Film Cooled Vane at High Freestream Turbulence and Transonic Conditions
… a row of shaped holes downstream of leading edge showerhead injection on both the pressure and suction surfaces (hereafter PS and SS) of a 1st stage NGV. Tests were performed at engine representative Mach and Reynolds numbers and high inlet turbulence intensity and large length scale at the …
-
"An Experimental Investigation of Showerhead Film Cooling Performance in a Transonic Vane Cascade at Low Freestream Turbulence"
… a first stage turbine vane with five rows of showerhead cooling was instrumented with platinum thin-film gauges to experimentally characterize film cooling performance. The vane was tested in a transonic vane cascade in Virginia Tech's heated, blow-down wind tunnel. Two freestream exit Mach …
-
Adiabatic and overall effectiveness in the showerhead of a film cooled turbine vane and effects of surface curvature on adiabatic effectiveness
… effectiveness measurements were taken in the showerhead region of the vane using adiabatic and matched Biot vane models, respectively. Measurements of overall effectiveness in the showerhead region are not found in the literature, and are a useful baseline for validating the results of …
-
Effect of Blowing Ratio on the Nusselt Number and Film Cooling Effectiveness Distributions of a Showerhead Film Cooled Blade in a Transonic Cascade
… ratio on the film cooling performance of a showerhead film cooled first stage turbine blade. The blade was instrumented with double-sided thin film heat flux gages to experimentally characterize the Nusselt number and film cooling effectiveness distributions over the surface of the blade. …
-
Systematic study of shaped-hole film cooling at the leading edge of a scaled-up turbine blade
… cooling is typically accomplished with dense "showerhead" arrangements of film cooling holes surrounding the stagnation point at the airfoil leading edge. In modern film cooling studies, shaped holes are prevalent in downstream areas of turbine airfoils; however, the literature contains few …
-
Measurements of adiabatic effectiveness from full coverage film cooling on a scaled turbine vane with laidback fanshaped holes
… with five rows of cylindrical holes in the showerhead and ten rows of laidback fanshaped holes distributed on the pressure and suction sides. The vane model was tested across a wide range of blowing ratios in several different coolant configurations including: individual rows on the pressure …
-
A radiation model of a Rapid Thermal Processing system
… the processed wafer in terms of the size of the showerhead and guard ring, the reflectivity of the showerhead and the chamber height.
-
Superposition in the leading edge region of a film cooled gas turbine vane
… of the adiabatic effectiveness for showerhead film cooling within the leading edge region, there have been no previous studies in which individual rows of the showerhead were tested with the explicit intent of validating superposition models. For the current investigation, a series …
-
Heat Transfer Measurements Using Thin Film Gauges and Infrared Thermography on a Film Cooled Transonic Vane
… experimental set up for the next comparison, a showerhead film cooled vane. This geometry was tested at BR=0, 2.0, Mex=0.76 and Tu=16%. The TFG and IR results did not compare well for heat transfer coefficient or film cooling effectiveness. The effects of measured and calculated recovery …
-
Modeling of fluorocarbon films deposition by HFCVD
… to achieve good quality films. First the inlet showerhead is simulated to determine the appropriate velocity profile for the reactor design simulations. The effects of the spacing between holes in the inlet showerhead, space near the walls, and the diameter of the showerhead holes have been …
-
Influence of Thermophilic Biofilms on Proliferation of Opportunistic Pathogens in Domestic Water Systems
… study, we determined the distinction between showerhead and drip-flow biofilms at the whole-community level and analyzed the coexistence of thermotolerant organisms with opportunistic genera, such as Legionella. We sampled eight showerheads and simulated four biofilm samples in the laboratory …
-
Experimental and computational investigation of film cooling on a large scale C3X turbine vane including conjugate effects
… cooling holes over the entire vane including a showerhead. Both configurations used internal impingement cooling representative of a 1st vane. Adiabatic effectiveness was also measured. No previous studies had shown the effect of injection on the mean and fluctuating velocity profiles for the …
-
Experimental investigation of overall effectiveness and coolant jet interactions on a fully cooled C3X turbine vane
… coverage film-cooling scheme with a five-row showerhead and 13 total rows of holes containing 149 total coolant holes. This study was the first study to make highly detailed measurements of overall effectiveness on a fully-cooled vane model and expands on previous studies of adiabatic and …
-
Experimental simulation and mitigation of contaminant deposition on film cooled gas turbine airfoils
… blade leading edge model with three rows of showerhead film cooling. It was then applied to turbine vane models with showerhead holes and row on pressure side consisting of either standard cylindrical holes or similar holes situated in a spanwise, recessed trench. Vane models were either …
-
Variable incidence angle film cooling experiments on a scaled up turbine airfoil model
… in the high curvature region of the showerhead depending on the incidence angle tested, and that the incidence angle effect persisted on the matched Biot number model. No previous studies had experimentally investigated the effects of incidence angle effects on overall effectiveness …
-
The attenuation and reduction of a simulated hot streak due to mainstream turbulence, hot streak pitch position and film cooling
… a fully film-cooled vane. To determine how the showerhead, suction side and pressure side coolant regions contributed to hot streak reduction, these regions were tested individually with and without the hot streak activated. The effect of mainstream turbulence level and coolant density ratio on …
-
Roughness impact on turbine vane suction side film cooling effectiveness
… the effect of mainstream turbulence level and showerhead coolant will be quantified. To gain insight into the state of the boundary layer just upstream of the row of film cooling holes, a hot-wire anemometer will be used to measure the velocity and turbulence profiles that exist under various …
-
MULTIPLEXED CHEMICAL SENSING AND THIN FILM METROLOGY IN PROGRAMMABLE CVD PROCESS.
… which is unique in effectively segmenting the showerhead gas flows by using exhaust gas pumping through the showerhead for each segment. In turn, mass spec sampling signals for each segment are multiplexed to obtain real-time signatures of reactor spatial behavior. In this dissertation, we have …
-
From genomes to metagenomes: Big data analysis of microbes related to public health
… of microbial communities growing on hospital showerheads using shotgun metagenomics, (2) evaluate the response of the gut microbiome to acute diarrhea episodes along a rural-to-urban gradient in Northern Ecuador, and (3) detect and quantify recent gene transfer events among closely related …
Page 1 of 3