Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"signal generating"”.

  1. An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma

    … electrode arrays, 3D-printed flow cells, and signal-generating magnetic bead bioconjugates for simultaneous detection of three biomarker proteins (cancer antigen 125 (CA-125), midkine (MK) and osteopontin (OPN)) associated with pediatric soft tissue sarcomas (PSTS). Magnetic bead bioconjugates …

    etsu Repository record for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab) Download PDF for An Electrochemical Immunoassay System for Measuring Circulating Protein Biomarkers of Pediatric Soft Tissue Sarcoma (opens in a new tab)

  2. A pulse generator with a temperature-dependent pulse spacing.

    … states. Each type of multivibrator produces a signal form unique to its type. The astable multivibrator produces a rectangular wave signal that is self-starting and free-running. The monostable multivibrator produces a rectangular pulse signal that is triggered externally for each pulse. The …

    ut-knoxville Repository record for A pulse generator with a temperature-dependent pulse spacing. (opens in a new tab)

  3. Embedded Passivated-Electrode Insulator-Based Dielectrophoretic Chromatography

    … of the properties of the particle medium, the signal generating the electric field, and the properties of the particles themselves. This method and its interaction with all small particles, including biological particles such as blood and cancer cells, has allowed devices utilizing this idea to …

    vt Repository record for Embedded Passivated-Electrode Insulator-Based Dielectrophoretic Chromatography (opens in a new tab)

  4. Robustness and generalization guarantees for statistical learning of generative models

    … processes with ideas from optimal transport and signal recovery, we formally address the generalization and robustness guarantees for the existing and newly suggested algorithms. More specifically, we consider the following three problems: First, we tackle the problem of domain adaptation, where …

    uiuc Repository record for Robustness and generalization guarantees for statistical learning of generative models (opens in a new tab)

  5. Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes

    … during earthquakes. Some of the measured signals have not been similar to what was expected during earthquake-induced liquefaction. Using artificially generated signals, several investigators have attempted to determine if existing piezometer fields designed to measure earthquake induced …

    unh-thes Repository record for Design and in situ testing of a piezometer system to measure earthquake -induced pore -pressure changes (opens in a new tab)

  6. Reconstruction of ECG Signals Acquired with Conductive Textile Eletrodes

    Physicians’ understanding of bio-signals, measured using medical instruments, becomes the foundation of their decisions and diagnoses of patients, as they rely strongly on what the instruments show. Thus, it is critical and very important to ensure that the instruments’ readings exactly reflect …

    ottawa-retro Repository record for Reconstruction of ECG Signals Acquired with Conductive Textile Eletrodes (opens in a new tab)

  7. A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique

    … carbon quantum dots (CQDs) were chosen as the signal-generating element for the device, and these were modified by nitrogen doping and silica capping for a more robust performance. The molecularly imprinted polymer (MIP) technique was employed to create reception sites on the sensing layer and …

    ubc Repository record for A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique (opens in a new tab) Download PDF for A smartphone-based fluorescent sensing paper for lactate measurement using carbon quantum dots and molecularly imprinted polymer technique (opens in a new tab)

  8. Role of redox systems in doxorubicin metabolism and doxorubicin-mediated cell signaling: a computational analysis

    … are dual-natured, containing a toxicity-generating module characterized by nicotinamide adenine dinucleotide phosphate (NADPH)-dependent Dox reductive conversion, as well as an ROS signal-generating module characterized by NADPH- and oxygen-dependent Dox redox cycling. The balance between …

    gatech Repository record for Role of redox systems in doxorubicin metabolism and doxorubicin-mediated cell signaling: a computational analysis (opens in a new tab)

  9. Silicon nanowire field-effect transistors for the detection of proteins

    … Wheatstone bridge, which allows canceling out of signal drift due to thermal fluctuations and dynamics of fluid flow. We showed that balancing the bridge significantly improves the signal-to-noise ratio. Further, we demonstrated the sensing of novel melanoma biomarker TROY at clinically relevant …

    bu Repository record for Silicon nanowire field-effect transistors for the detection of proteins (opens in a new tab)

  10. Employing Functional Nucleic Acids as Molecular Recognition Elements Within Modular Biosensors

    … assemblies capable of performing target-induced signal generation. Such assemblies, known as biosensors, are composed of a molecular recognition element (MRE) and a signal generating transduction element. One MRE class that has received great attention in recent years is functional nucleic acids, …

    mcmaster Repository record for Employing Functional Nucleic Acids as Molecular Recognition Elements Within Modular Biosensors (opens in a new tab)

  11. Adaptive Pre-Distort.ion for Laser Diodes with Direct Modulation Frequencies up to 1 GHz

    … answer involves improving the linearity of signal generating light sources. Residential customers will gradually seek improvements to the broadband services that are presently offered by low-cost, analogue cable television. Unfortunately, device fabrication techniques that minimize the …

    sask Repository record for Adaptive Pre-Distort.ion for Laser Diodes with Direct Modulation Frequencies up to 1 GHz (opens in a new tab)

  12. A hybrid microwave heterodyne receiver design for use in distributed fibre sensing of spontaneous Brillouin backscatter

    … in order to detect a Brillouin backscatter signal which, due to its very nature, is able to divulge information pertaining to the temperature and strain being applied to an optical fibre over a distance of many tens of kilometres. As the resolution of both these measurands has improved, …

    soton Download PDF for A hybrid microwave heterodyne receiver design for use in distributed fibre sensing of spontaneous Brillouin backscatter (opens in a new tab)

  13. Thesis on behavioural asset pricing and portfolio choice

    … fallacy" type, both observe the public signal about the fundamental value each period. The rational investor holds correct beliefs on the stochastic process of the signal, whereas the gambler's fallacy investor falsely believes that the sequence of signals should exhibit systematic …

    oxford Repository record for Thesis on behavioural asset pricing and portfolio choice (opens in a new tab)

  14. Quadrature Frequency Synthesis for Wideband Wireless Transceivers

    … low-power quadrature generation. A harmonic-rich signal, containing both even and odd harmonics of the input reference signal, is generated using a digital pulse slimmer. Two ILO chains are used to lock on to the 10th and 11th harmonics of the reference signal generating the 20 GHz and the 22 GHz …

    umn Repository record for Quadrature Frequency Synthesis for Wideband Wireless Transceivers (opens in a new tab)

  15. Structural and functional remodeling of neuronal circuitry surrounding implanted electrodes

    … commonly attributed to instability and loss of signal over time. However, these metrics do not reliably predict signal loss, and device failure modes remain elusive. Here, this work provides fundamental insight into biological mechanisms that contribute to these failure modes, as well as …

    msu Repository record for Structural and functional remodeling of neuronal circuitry surrounding implanted electrodes (opens in a new tab)

  16. Steifigkeitsuntersuchungen an humanen Kadaverwirbelkörpern vor und nach Vertebroplastie mit MRTsignalgebenden Knochenzementen

    … ob mittels Vertebroplastie eingebrachte MRTsignalgebende Knochenzemente die Steifigkeit frakturierter, osteoporotischer Wirbelkörper wieder herstellen können. Die Zementoplastie, d.h. das Einbringen von Knochenzement in einen Wirbelkörper, vornehmlich die Vertebroplastie und Kyphoplastie, …

    fu-berlin Repository record for Steifigkeitsuntersuchungen an humanen Kadaverwirbelkörpern vor und nach Vertebroplastie mit MRTsignalgebenden Knochenzementen (opens in a new tab)

  17. ESSAYS ON LEARNING UNDER MODEL UNCERTAINTY

    … cascade depends on the details of people's data-generating processes, so it leaves an open question of whether cascades are prevalent in the social learning. In the essay, I re-examine the problem under the assumption that individuals are ambiguous about others' data-generating process and make …

    cornell Repository record for ESSAYS ON LEARNING UNDER MODEL UNCERTAINTY (opens in a new tab)

  18. Portable electrochemical and plasmonic biosensors for biomedical application

    … smartwatchs or even headsets, can achieve signal generating and receiving by using interfaces like camera, flashlight, audio-jack, micro-USB and wireless module. On the other side, development in the micro-fluid system enables the integration of different diagnosis techniques like …

    uiuc Repository record for Portable electrochemical and plasmonic biosensors for biomedical application (opens in a new tab)

  19. Experimentální ultrazvuková měření pomocí LabView

    Tato bakalářská práce se zabývá ultrazvukovým polem, měřením jeho útlumu a měřením pomocí LabVIEW. Jsou zde vysvětleny základní parametry ultrazvukových měničů a ultrazvukového pole. Byly navrženy dvě metody pro měření útlumu a modifikace té druhé. V této práci jsou uvedeny dva programy v LabVIEW …

    brno-tech Repository record for Experimentální ultrazvuková měření pomocí LabView (opens in a new tab)

  20. Tester vlakového zabezpečovače

    Tato diplomová práce se zabývá popisem liniového systému vlakového zabezpečovače a jeho funkčních vlastností, a to zejména s ohledem na přenos kódovaného signálu ze stacionární části na drážní vozidlo. Dále práce shrnuje podstatné informace o způsobu snímání otáček soukolí drážního vozidla a …

    brno-tech Repository record for Tester vlakového zabezpečovače (opens in a new tab)

Page 1 of 2