Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 85 for “"silicon detectors"”.

  1. Characterization of Czochralski silicon detectors

    … of irradiated and non-irradiated segmented detectors made of high-resistivity (>1 kΩcm) magnetic Czochralski (MCZ) silicon. It is shown that the radiation hardness (RH) of the protons of these detectors is higher than that of devices made of traditional materials such as Float Zone (FZ) …

    aalto Repository record for Characterization of Czochralski silicon detectors (opens in a new tab)

  2. The Two Sides of Silicon Detectors

    Results are presented on in situ irradiation of silicon detector's at cryogenic temperature. The results show that irradiation at cryogenic temperatures does not detrimentally effect a silicon detectors performance when compared to its irradiation at room temperature. Operation of silicon devices …

    glasgow Download PDF for The Two Sides of Silicon Detectors (opens in a new tab)

  3. Double-sided 3D silicon detectors for the high-luminosity LHC

    … density requires a finer segmentation of the detectors employed to investigate the particle collisions. Over the projected lifetime of the HL-LHC, the tracking detectors will have to withstand a five to ten times higher radiation dose than that at the LHC. In silicon detectors, radiation …

    freiburg-diss Repository record for Double-sided 3D silicon detectors for the high-luminosity LHC (opens in a new tab)

  4. Application of atomic layer deposited thin films to silicon detectors

    Silicon is used in a variety of semiconductor radiation and particle detectors due to its reasonable cost, good availability and processability, and performance at room temperature. Pixel detectors made of silicon are used for particle tracking at different high-energy physics experiments, …

    aalto Repository record for Application of atomic layer deposited thin films to silicon detectors (opens in a new tab)

  5. Silicon detectors for the upgrade of the HL-LHC experiments

    … Solenoid is one of two large general-purpose detectors that contributed to the recent discovery of the Higgs boson and many other physics results in particle physics. Its innermost part is called the Tracker, and it is a high-precision instrument that measures the trajectories of the created …

    greece Repository record for Silicon detectors for the upgrade of the HL-LHC experiments (opens in a new tab)

  6. Dark Matter Searches with Germanium and Silicon detectors in SuperCDMS and CUTE

    … Matter Search (SuperCDMS) uses germanium and silicon semiconductor detectors to search for dark matter. Particle interactions with these detectors create observable signals in the form of phonons and electron-hole pair. We apply a voltage bias across these detectors, utilising the …

    queens Repository record for Dark Matter Searches with Germanium and Silicon detectors in SuperCDMS and CUTE (opens in a new tab)

  7. The passage from microstrip to pixel silicon detectors for tracking particles in space

    … require systems equipped with tracking detectors. The sensitive area of detectors required for tracking spans from cm2 to m2. Silicon microstrip detectors have been the elective technology for tracking particles in space for several decades. Their stability, reliability and low power …

    trento Repository record for The passage from microstrip to pixel silicon detectors for tracking particles in space (opens in a new tab)

  8. New generation fast Silicon detectors for timing and particle Identification High Energy Physics and applications

    … breeding ground for the development of particle detectors specialized in reconstructing the time coordinate of events with great accuracy. This thesis presents the results obtained from the characterization and optimization of Low Gain Avalanche Detectors (LGADs) designed for the End-Cap Timing …

    ku Repository record for New generation fast Silicon detectors for timing and particle Identification High Energy Physics and applications (opens in a new tab)

  9. Development of a two-photon absorption - TCT system and study of radiation damage in silicon detectors

    … to the development of radiation hard silicon detectors for the application in high energy physics experiments.<br>First, a study was carried out to investigate radiation induced effects in Low Gain Avalanche Detectors (LGADs) and how these effects change with annealing of the devices. …

    freiburg-diss Repository record for Development of a two-photon absorption - TCT system and study of radiation damage in silicon detectors (opens in a new tab)

  10. Robust track based alignment of the ATLAS silicon detectors and assessing patron distribution uncertainties in drell-yan processes

    <p>The ATLAS Experiment is one of the four large detectors located at the Large Hadron Collider (LHC) at CERN in Geneva, Switzerland. In summer 2008, ATLAS is expected to start collecting data from proton-proton collisions at 14 TeV centre-of-mass energy. In the centre of the detector, the …

    oxford Repository record for Robust track based alignment of the ATLAS silicon detectors and assessing patron distribution uncertainties in drell-yan processes (opens in a new tab)

  11. Low-Energy Proton Accelerator for Detector Testing

    … of the recoil protons into large-area silicon detectors for this purpose. A 30~keV proton accelerator was designed, created, and commissioned in order to characterize silicon detectors of this type. Final construction and initial results on the performance of the accelerator are …

    manitoba Repository record for Low-Energy Proton Accelerator for Detector Testing (opens in a new tab)

  12. Development of radiation hard radiation detectors : differences between Czochralski silicon and float zone silicon

    … of this work was to develop radiation hard silicon detectors. Radiation detectors made of silicon are cost effective and have excellent position resolution. Therefore, they are widely used for track finding and particle analysis in large high-energy physics experiments. Silicon detectors …

    aalto Repository record for Development of radiation hard radiation detectors : differences between Czochralski silicon and float zone silicon (opens in a new tab)

  13. Si detektorių pažaidos 192Ir gama spinduliuote tyrimas /

    Investigation of the Radiation Damage of Silicon Detectors by 192Ir Emitted Gamma Rays.

    vilnius Repository record for Si detektorių pažaidos 192Ir gama spinduliuote tyrimas / (opens in a new tab)

  14. A Precise Measurement of the Lifetime of B-mesons, Measurement of CP-violation Parameters of Bs-mesons, the ATLAS Experiment at the LHC, and Development of Silicon Detectors for Future Particle Physics Experiments

    … and mitigating the effect of radiation on the detectors, which is inescapable in their operating environment. Datasets collected by the ATLAS detector at the Large Hadron Collider (LHC) are used for the analyses involving the decays of b-hadrons. These analyses are supplemented by a detailed …

    unm Repository record for A Precise Measurement of the Lifetime of B-mesons, Measurement of CP-violation Parameters of Bs-mesons, the ATLAS Experiment at the LHC, and Development of Silicon Detectors for Future Particle Physics Experiments (opens in a new tab)

  15. D meson reconstruction at star using the silicon vertex tracker (svt)

    … at sqrt(sNN) = 200 GeV at STAR using existing silicon detectors (SVT and SSD). The measurements are performed using a secondary vertexing technique that exploits the resolution given by the silicon detectors available in STAR. We will study D-meson yields, significances, and discuss the …

    wayne-thes Repository record for D meson reconstruction at star using the silicon vertex tracker (svt) (opens in a new tab)

  16. PASSIVATED IMPLANTED PLANAR SILICON (PIPS) DETECTORS FOR MEASUREMENT OF RADIOXENON

    Silicon detectors are analyzed as an alternative to plastic scintillators for beta detection based on their higher energy resolution. A radioxenon detection setup was created with the intent of comparing the absolute efficiency of the beta-gamma coincidence measurements between a silicon detector …

    gatech Repository record for PASSIVATED IMPLANTED PLANAR SILICON (PIPS) DETECTORS FOR MEASUREMENT OF RADIOXENON (opens in a new tab)

Page 1 of 5