Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 53 for “"simple payback"”.

  1. The Economic Optimization of Wind Turbine Design

    … capacity. The levelized cost of energy and simple payback are the figures of merit being minimized. Blade element momentum theory is used to calculate the power produced by the wind turbine rotor. Increasing the rotor diameter increases the power delivered to the generator at all wind speeds …

    gatech Repository record for The Economic Optimization of Wind Turbine Design (opens in a new tab)

  2. Implementation Rate Predictors of the South Dakota State University Industrial Assessment Center

    … included cost savings, implementation cost, and simple payback. The South Dakota State University IAC implementation rates were also compared with the overall implementation rate of the entire IAC program. The following conclusions were made while examining the implementation rates of the SDSU …

    sdstate Repository record for Implementation Rate Predictors of the South Dakota State University Industrial Assessment Center (opens in a new tab)

  3. Can micro-scale anaerobic digestion be viable? An investigation of the techno-economics and flexibility of micro-scale anaerobic digestion for future routes to the market.

    … of a trace element solution. The plant had a simple payback period of 148 years due to low revenues. A technoeconomic analysis was performed for a theoretical micro-scale AD plant with a yearly input of 119 tonnes of food waste and 6 tonnes of vegetable oil. The simple payback time of the …

    whiterose Download PDF for Can micro-scale anaerobic digestion be viable? An investigation of the techno-economics and flexibility of micro-scale anaerobic digestion for future routes to the market. (opens in a new tab)

  4. Energy Consumption Characteristics of Light Manufacturing Facilities in the Northern Plains

    … were ranked based on frequency of occurrence, simple payback period, energy conserved, cost conserved, and ease of implementation. This study examined which characteristics of ECOs can be most useful to industrial personnel such as maintenance supervisors, plant managers, and utility personnel. …

    sdstate Repository record for Energy Consumption Characteristics of Light Manufacturing Facilities in the Northern Plains (opens in a new tab)

  5. An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools

    … building). From an LCC perspective, the AEI's simple payback period exceeds its 20 year lifespan. The NPV and IRR are calculated as highly negative numbers which indicates that the financial cons of the AEI outweigh the pros. In summary, from an indoor energy reduction lens the AEI will not …

    calgary Repository record for An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools (opens in a new tab)

  6. Transforming an existing facility into an Energy Plus building

    … $7,810 for a return on investment of 9.5% with a simple payback period of 11 years while reducing carbon dioxide emissions by more than 1,200 tons over the next 20 years.

    utc Repository record for Transforming an existing facility into an Energy Plus building (opens in a new tab)

  7. Simulation and Analysis of Energy Consumption for an Energy-Intensive Academic Research Building

    … MMBtu, reducing annual energy use by 25.3%. The simple payback period for the proposed measures as a single project is estimated to be less than one year. Due to the high-tech and unique usage of the Kim Engineering Building, including cleanrooms and research labs, this thesis also contributes to …

    maryland Repository record for Simulation and Analysis of Energy Consumption for an Energy-Intensive Academic Research Building (opens in a new tab)

  8. Heat recovery for dairies : case studies

    … savings of $423 to $800 per year were realized. Simple payback times for these systems ranged from approximately two to four years.</p>

    ut-knoxville Repository record for Heat recovery for dairies : case studies (opens in a new tab)

  9. Assessment of compressed air energy storage system (CAES)

    … trip efficiencies, it is estimated that the simple payback for CAES is significantly (5 to 25 years) lower than the PHES (11 to 53 years). Direct use of the power from the wind turbine fed to the compressors can raise the roundtrip efficiencies close to 82 percent for CAES.

    utc Repository record for Assessment of compressed air energy storage system (CAES) (opens in a new tab)

  10. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  11. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  12. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  13. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  14. Rooftop solar photo voltaic potential: Rand Water as case study

    … rate of return, levelised cost of energy and simple payback period. The reduction in greenhouse gas emissions is discussed extensively in literature but it is not included as environmental potential or greenhouse payback time. This research proposes a methodology to analyse potential of a …

    nwu-za Repository record for Rooftop solar photo voltaic potential: Rand Water as case study (opens in a new tab)

  15. Cost analysis of LEED certified United States navy buildings

    … building, as well as, the calculation of a simple payback period for the US Navy LEED certified buildings. The results indicate that although some of the building had satisfactory results, half would not be considered economically feasible. Furthermore, neither the level of LEED …

    nps Repository record for Cost analysis of LEED certified United States navy buildings (opens in a new tab)

  16. DESIGN, THERMAL SIMULATION AND ECONOMIC FEASIBILITY ANALYSIS OF A PLANT FACTORY HOUSED IN A UNDERGROUND MINE DRIFT

    … internal rate of return, profitability index and simple payback period showed that the project is economically feasible. The simple payback period is 6.7 years.

    sask Repository record for DESIGN, THERMAL SIMULATION AND ECONOMIC FEASIBILITY ANALYSIS OF A PLANT FACTORY HOUSED IN A UNDERGROUND MINE DRIFT (opens in a new tab)

  17. Sustainable Energy Modeling for Office Buildings Through Energy Efficiency Strategies

    … Economic performance was assessed using Simple Payback Period (SPP) and Discounted Payback Period (DPP) to evaluate financial feasibility across different investment and energy-saving levels. Results show that that combined retrofit packages consistently outperformed single-measure …

    concordia Download PDF for Sustainable Energy Modeling for Office Buildings Through Energy Efficiency Strategies (opens in a new tab)

  18. Retrofitting a high-rise residential building to reduce energy use by a factor of 10

    … analysis tools.Capital cost estimates and simple payback periods for each retrofit are also presented. The total cost to retrofit the building is estimated to be $3,123,000 and the resulting utility savings from the retrofits are approximately $150,000 per year. This is a factor 6.0 …

    sask Repository record for Retrofitting a high-rise residential building to reduce energy use by a factor of 10 (opens in a new tab)

Page 1 of 3