Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 35 for “"simple payback period"”.

  1. Energy Consumption Characteristics of Light Manufacturing Facilities in the Northern Plains

    … were ranked based on frequency of occurrence, simple payback period, energy conserved, cost conserved, and ease of implementation. This study examined which characteristics of ECOs can be most useful to industrial personnel such as maintenance supervisors, plant managers, and utility personnel. …

    sdstate Repository record for Energy Consumption Characteristics of Light Manufacturing Facilities in the Northern Plains (opens in a new tab)

  2. An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools

    … building). From an LCC perspective, the AEI's simple payback period exceeds its 20 year lifespan. The NPV and IRR are calculated as highly negative numbers which indicates that the financial cons of the AEI outweigh the pros. In summary, from an indoor energy reduction lens the AEI will not …

    calgary Repository record for An Exploration of how Energy-Related Ecosystem Services Provided by Extensive Green Roofs in Alberta may be Quantified Using Life Cycle Assessment Tools (opens in a new tab)

  3. Transforming an existing facility into an Energy Plus building

    … $7,810 for a return on investment of 9.5% with a simple payback period of 11 years while reducing carbon dioxide emissions by more than 1,200 tons over the next 20 years.

    utc Repository record for Transforming an existing facility into an Energy Plus building (opens in a new tab)

  4. Simulation and Analysis of Energy Consumption for an Energy-Intensive Academic Research Building

    … MMBtu, reducing annual energy use by 25.3%. The simple payback period for the proposed measures as a single project is estimated to be less than one year. Due to the high-tech and unique usage of the Kim Engineering Building, including cleanrooms and research labs, this thesis also contributes to …

    maryland Repository record for Simulation and Analysis of Energy Consumption for an Energy-Intensive Academic Research Building (opens in a new tab)

  5. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  6. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  7. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  8. Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County

    … measurements. It further evaluates the simple payback period (SPP) of PoE systems and assesses their role in supporting local sustainability goals outlined in the Harris County Climate Action Plan. With the integration of advanced lighting controls, including dimming and occupancy …

    tamu Repository record for Assessing Energy Savings Through Power Over Ethernet (PoE) Lighting in Commercial Buildings: A Case Study in Harris County (opens in a new tab)

  9. Rooftop solar photo voltaic potential: Rand Water as case study

    … rate of return, levelised cost of energy and simple payback period. The reduction in greenhouse gas emissions is discussed extensively in literature but it is not included as environmental potential or greenhouse payback time. This research proposes a methodology to analyse potential of a …

    nwu-za Repository record for Rooftop solar photo voltaic potential: Rand Water as case study (opens in a new tab)

  10. Cost analysis of LEED certified United States navy buildings

    … building, as well as, the calculation of a simple payback period for the US Navy LEED certified buildings. The results indicate that although some of the building had satisfactory results, half would not be considered economically feasible. Furthermore, neither the level of LEED …

    nps Repository record for Cost analysis of LEED certified United States navy buildings (opens in a new tab)

  11. DESIGN, THERMAL SIMULATION AND ECONOMIC FEASIBILITY ANALYSIS OF A PLANT FACTORY HOUSED IN A UNDERGROUND MINE DRIFT

    … m2 with base case of 30℃/24℃ in light/dark period temperature. At the beginning (first day) of operation the UGPF can reduce 0.0748 kW/m2 (kW per unit surface area of rock envelope) of cooling load in light period but after 3 years it is reduced to 0.0195 kW/m2 which is 26.1% of initial …

    sask Repository record for DESIGN, THERMAL SIMULATION AND ECONOMIC FEASIBILITY ANALYSIS OF A PLANT FACTORY HOUSED IN A UNDERGROUND MINE DRIFT (opens in a new tab)

  12. Sustainable Energy Modeling for Office Buildings Through Energy Efficiency Strategies

    … Economic performance was assessed using Simple Payback Period (SPP) and Discounted Payback Period (DPP) to evaluate financial feasibility across different investment and energy-saving levels. Results show that that combined retrofit packages consistently outperformed single-measure …

    concordia Download PDF for Sustainable Energy Modeling for Office Buildings Through Energy Efficiency Strategies (opens in a new tab)

  13. Comparative analysis of the VRF system and conventional HVAC systems, focused on life-cycle cost

    … Net Savings, Savingto- Investment ratio, and payback years. The major findings are that the VRF system has an average of thirty-nine percent HVAC energy consumption savings. As for the results of the life-cycle cost analysis, the average of simple payback period is twelve years.

    gatech Repository record for Comparative analysis of the VRF system and conventional HVAC systems, focused on life-cycle cost (opens in a new tab)

  14. Occupancy sensor networks for improved lighting system control

    … algorithm. Eight data fusion methods, from the simple logical functions to more sophisticated Bayesian belief network and neural network methods, were applied in this research. The most advanced of these methods, that incorporate knowledge of detector performance and typical occupancy patterns, …

    nebraska Repository record for Occupancy sensor networks for improved lighting system control (opens in a new tab)

  15. Energy optimization of the production of cellulosic ethanol from southern pine

    … required in this alternate scenario returns a simple payback period of 1.1 years through the additional revenue of the increased electricity sale.

    gatech Repository record for Energy optimization of the production of cellulosic ethanol from southern pine (opens in a new tab)

  16. Can micro-scale anaerobic digestion be viable? An investigation of the techno-economics and flexibility of micro-scale anaerobic digestion for future routes to the market.

    … of a trace element solution. The plant had a simple payback period of 148 years due to low revenues. A technoeconomic analysis was performed for a theoretical micro-scale AD plant with a yearly input of 119 tonnes of food waste and 6 tonnes of vegetable oil. The simple payback time of the …

    whiterose Download PDF for Can micro-scale anaerobic digestion be viable? An investigation of the techno-economics and flexibility of micro-scale anaerobic digestion for future routes to the market. (opens in a new tab)

  17. Implementing the Lean Enablers for Systems Engineering in a Spacecraft Design/Development Company

    … benefit from implementation, and calculated simple payback period. The analysis showed that implementing those enablers provides average payback in approximately three months. The recommendation herein is that the Company implements the selected LEfSE to improve cost and schedule performance …

    lmu Repository record for Implementing the Lean Enablers for Systems Engineering in a Spacecraft Design/Development Company (opens in a new tab)

  18. Determining the feasibility of a steersand- oxen-beef production system in South Africa

    … investment, annualised return on investment and simple payback period. These were used to compare the feasibility, profitability and cash flow of the different production systems with one another in different scenarios, which simulated the main production areas of South Africa. The study …

    nwu-za Repository record for Determining the feasibility of a steersand- oxen-beef production system in South Africa (opens in a new tab)

  19. Solar-Assisted Heat Pumps for Low-Temperature Industrial Process Heat Applications

    … is. only marginal. In the economic analysis the simple payback period, discounted payback period, and levelized cost methods are employed to analyze the feasibility of the SAHP system. The payback period of the SAHP system, with electrical resistance heater being the displaced energy system, …

    odu Repository record for Solar-Assisted Heat Pumps for Low-Temperature Industrial Process Heat Applications (opens in a new tab)