Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 13 of 13 for “"simple shear connections"”

  1. A comparison of double clip angle shear connections to shear tab connections in industrial applications

    In structural steel connection design, simple shear connections are one of the most common connection types utilized. The industry, especially from the side of the engineer, tends to lean toward using Double Clip Angle Connections as the default standard for simple shear connections. A double clip …

    ksu Repository record for A comparison of double clip angle shear connections to shear tab connections in industrial applications (opens in a new tab)

  2. Preliminary analysis and design of a test setup for evaluating lateral resistance of steel gravity framing systems

    … of this gravity system are connected using “simple shear” connections that are designed and assumed to behave as “perfect pins” that have no flexural strength or stiffness, thus generating no moment resistance at the connection. Nevertheless, past research has shown that the gravity system …

    texas Repository record for Preliminary analysis and design of a test setup for evaluating lateral resistance of steel gravity framing systems (opens in a new tab)

  3. Contribution of Shear Connections to the Lateral Stiffness and Strength of Steel Frames

    … 1994, research efforts involving the capacity of simple gravity connections have since increased significantly. Typically, a building includes more gravity connections than moment connections, yet the moment resistance contributions of the gravity connections are neglected in design. Based on the …

    ohiolink Repository record for Contribution of Shear Connections to the Lateral Stiffness and Strength of Steel Frames (opens in a new tab)

  4. The role of the floor system in the seismic response of steel gravity framing

    The flexural response of composite clip angle connections to cyclic inter-story drift was experimentally investigated in this test program. Testing was performed on a cruciform sub-assembly with W21x55 girders framing in to a W12x96 column with varied clip angle details. A composite slab was cast …

    texas Repository record for The role of the floor system in the seismic response of steel gravity framing (opens in a new tab)

  5. Optimal wind bracing systems for multi-storey steel buildings

    … are classified as completely rigid (moment) and simple (shear) connections. In theory, completely rigid connections can not undergo rotation and simple connections can not transfer moment. However, in reality rigid connections have a relative flexibility which makes them to rotate and simple …

    metu Repository record for Optimal wind bracing systems for multi-storey steel buildings (opens in a new tab)

  6. Double Angle Framing Connections Subjected to Shear and Tension

    … connection) is one of the most commonly used simple shear connections, and many investigations have been conducted on this type of connection. However, most of these investigations have focused on either the strength or the moment-rotation relationship under shear loading. Several …

    vt Repository record for Double Angle Framing Connections Subjected to Shear and Tension (opens in a new tab)

  7. Parametric Study on the Behavior of All-Bolted Single-Angle Connections in Fire

    All-bolted single-angle connections are simple (shear) connections commonly used in steel structures; however, there is limited guidance on appropriately designing single-angle connections for fire safety in steel structures. In the context of fire, the strength of single-angle connections and …

    ohiolink Repository record for Parametric Study on the Behavior of All-Bolted Single-Angle Connections in Fire (opens in a new tab)

  8. Application of Ductile Yield Link in Glulam Moment Connections

    Wood beam-column connections have traditionally been designed as simple shear connections, ignoring their potential moment capacity. A major reason for not utilizing such moment connections is linked to the brittle limit states that wood components exhibit. The purpose of this research was to …

    vt Repository record for Application of Ductile Yield Link in Glulam Moment Connections (opens in a new tab)

  9. STRAIN AND TEMPERATURE MEASUREMENT FROM DISTRIBUTED FIBER OPTIC SENSORS IN PERFORMANCE-BASED FIRE ENGINEERING

    … in long-span composite floor beams with simple shear connections are performed under compartment fires"--Abstract, p. iv

    must-thes Repository record for STRAIN AND TEMPERATURE MEASUREMENT FROM DISTRIBUTED FIBER OPTIC SENSORS IN PERFORMANCE-BASED FIRE ENGINEERING (opens in a new tab)

  10. Investigation of Simple Shear Connection Economy

    … the eastern part, to leave the design of simple shear connections up to the steel fabricator. The design engineer typically provides notes on the design drawings directing the fabricator to design the shear connections for: (a) one-half the maximum uniform load; (b) the maximum number of …

    ohiolink Repository record for Investigation of Simple Shear Connection Economy (opens in a new tab)

  11. One-sided Steel Shear Connections in Column Removal Scenario

    … disproportionately large part of the structure. Connections play a major role in ensuring general integrity of different types of steel structural systems. Hence, numerical investigations have been performed to extend the current body of knowledge on connections and, consequently, the structural …

    alberta Repository record for One-sided Steel Shear Connections in Column Removal Scenario (opens in a new tab)

  12. Testing of extended shear tab connections subjected to shear

    Shear tab, or single-plate, connections are widely used as simple shear connections in the construction of steel structures. These connections take the form of a single plate shop welded to a supporting column or girder. During erection, the supported beam is moved into place and connected to the …

    mcgill Repository record for Testing of extended shear tab connections subjected to shear (opens in a new tab)

  13. The behaviour of steel fin plate connections in fire

    … complexity. Although, the evaluation of steel connections' performance at ambient temperature has been a continuous research topic, the investigation of steel connections at elevated temperatures has only recently been tackled by researchers. However, the determination of the behaviour, …

    whiterose Repository record for The behaviour of steel fin plate connections in fire (opens in a new tab)