Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 2 of 2 for “"simulated workplace protection factor"”

  1. Protection of Firefighters against Combustion Aerosol Particles: Simulated Workplace Protection Factor of a Half-Mask Respirator

    … with two P100 filters. We determined the Simulated Workplace Protection Factor (SWPF) for 11 firefighters wearing elastomeric half-mask respirators and performing activities simulating those conducted during fire overhaul operations. The tests were performed in a controlled laboratory …

    ohiolink Repository record for Protection of Firefighters against Combustion Aerosol Particles: Simulated Workplace Protection Factor of a Half-Mask Respirator (opens in a new tab)

  2. Performance of Filtering Facepieces and Powered Air-purifying Respirators Challenged with Different Aerosols

    … were compared to those obtained with real workplace aerosols. The effects of multiple factors such as challenge aerosol type, breathing flow rates including constant inhalation flow and cyclic flow, particle size, relative humidity of the ambient air, and respirator type on the RPDs’ …

    ohiolink Repository record for Performance of Filtering Facepieces and Powered Air-purifying Respirators Challenged with Different Aerosols (opens in a new tab)