Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 322 for “"simultaneous measurement"”.

  1. Simultaneous Measurement of the Mechanics and Energetics of Cardiac Trabeculae

    This study is the first to have measured, simultaneously, the mechanics and energetics of isolated mammalian cardiac trabeculae. Measurements were made using our unique micromechanocalorimeter and work-loop calorimeter. Using these two unique devices, we measured simultaneously the stress (force …

    auckland-ms Repository record for Simultaneous Measurement of the Mechanics and Energetics of Cardiac Trabeculae (opens in a new tab)

  2. Simultaneous measurement of monoaromatic hydrocarbons and dicarboxylic acids in ambient air

    … and dicarboxylic acids were measured simultaneously in this work. A method was developed for aromatic hydrocarbons: collection on Tenax and charcoal, thermal desorption, and gas chromatographic analysis. Another method was verified for diacids: collection on quartz filter, conversion …

    unlv Repository record for Simultaneous measurement of monoaromatic hydrocarbons and dicarboxylic acids in ambient air (opens in a new tab) Download PDF for Simultaneous measurement of monoaromatic hydrocarbons and dicarboxylic acids in ambient air (opens in a new tab)

  3. Co-Located Fiber Bragg Gratings for Simultaneous Measurement of Temperature and Strain

    … I' and 2 Its are predicted. When subjected to simultaneous temperature and strain fields, errors of up to 130' and 1700 Its were encountered. The discrepancy is traced to the use of a refraction grating based optical spectrum analyzer, an accepted piece of test equipment in Bragg grating sensor …

    odu Repository record for Co-Located Fiber Bragg Gratings for Simultaneous Measurement of Temperature and Strain (opens in a new tab)

  4. Simultaneous Measurement of Key Odorants at their Sensory Thresholds in Juice Grapes

    … e.g. ‘Concord’ and ‘Niagara’. Convenient measurement of these compounds is of interest to grape breeders who wish to either increase or decrease their concentrations in grape varieties. Previous approaches for measurement of these odorants either cannot measure all compounds in a single …

    cornell Repository record for Simultaneous Measurement of Key Odorants at their Sensory Thresholds in Juice Grapes (opens in a new tab)

  5. Simultaneous measurement of strain and temperature using liquid core optical fiber sensors

    … can be used to sense both strain and temperature simultaneously. This liquid core fiber sensor is comprised of a hollow core optical fiber filled with a liquid of a known index of refraction which is slightly higher than that of the silica tube which acts as the cladding. The refractive index …

    vt Repository record for Simultaneous measurement of strain and temperature using liquid core optical fiber sensors (opens in a new tab)

  6. Refining simultaneous measurement of vitamin d and other secosteroids in human serum

    … neurology and cognition but rarely quantified simultaneously with other vitamin D metabolites, steroids, or hormones.The aim of this study was to develop and validate a simple, effective, and reliable method to measure major secosteroids and vitamin D metabolites in human serum with precision, …

    msu Repository record for Refining simultaneous measurement of vitamin d and other secosteroids in human serum (opens in a new tab)

  7. Simultaneous measurement of full-field vibration modes using Electronic Speckle Pattern Interferometry (ESPI)

    … using ESPI, even when multiple modes are simultaneously present. The method involves measuring the surface shape of a vibrating plate at high frame rate using a Michelson interferometer and high-speed camera. The vibration is either excited by white (random) noise or by impact. Fourier …

    ubc Repository record for Simultaneous measurement of full-field vibration modes using Electronic Speckle Pattern Interferometry (ESPI) (opens in a new tab) Download PDF for Simultaneous measurement of full-field vibration modes using Electronic Speckle Pattern Interferometry (ESPI) (opens in a new tab)

  8. Simultaneous measurement of strain and temperature using two-mode elliptical core optical fiber

    … be utilized to sense both strain and temperature simultaneously. To develop such a sensor, we sandwich a section of two-mode elliptical core (e-core) fiber between two partially reflecting mirrors. This configuration can be considered as an intrinsic Fabry-Perot interferometer, in which the …

    vt Repository record for Simultaneous measurement of strain and temperature using two-mode elliptical core optical fiber (opens in a new tab)

  9. A Novel Assay for Simultaneous Measurement of DNA Double-Strand Repair by Two Pathways

    … able to monitor repair readily by both pathways simultaneously. This study describes the development and testing of a new assay system to simultaneously quantitate repair by the two mechanisms. This accomplishment is important because it will permit investigation of conditions where the DSB will …

    texas-state Repository record for A Novel Assay for Simultaneous Measurement of DNA Double-Strand Repair by Two Pathways (opens in a new tab)

  10. Simultaneous Measurement of Isotope-free Tracer and Interdiffusion Coefficients in Sandwich Type Diffusion Couples

    … can be quite burdensome in alloys since separate measurements must be carried out for each alloy composition. A new formalism recently developed by I.V. Belova, N.S. Kulkarni, Y.H. Sohn and G.E. Murch, based on linear response theory combined with the Boltzmann–Matano method allows determination …

    ucf Repository record for Simultaneous Measurement of Isotope-free Tracer and Interdiffusion Coefficients in Sandwich Type Diffusion Couples (opens in a new tab)

  11. A Simultaneous Measurement of the Branching Fractions of Ten B to Double Charm Decays

    This dissertation presents a simultaneous measurement of the branching fractions of ten <i>B</i> &#8594; <i>D</i><sup>(</sup>*<sup>)</sup><i>D</i>&#773;<sup>(</sup>*<sup>)</sup> decays. The measurements are derived from a sample of 2.32 × 10<sup>8</sup> <i>BB</i>&#773; pairs collected by the BABAR …

    maryland Repository record for A Simultaneous Measurement of the Branching Fractions of Ten B to Double Charm Decays (opens in a new tab)

  12. Machine vision system for simultaneous measurement of dimensional changes and soil release in printed fabric

    … that could become a standard for making both measurements simultaneously. To make these measurements, printed fabric swatches are scanned before and after wash using an off-the-shelf scanner. Reference points (called shrinkage dots) are placed on the fabric swatches and then located in the …

    ttu Repository record for Machine vision system for simultaneous measurement of dimensional changes and soil release in printed fabric (opens in a new tab)

  13. A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth

    … generally do not have co-located PM2.5 measurements and are too expensive to deploy in large numbers. The objective of this work was to develop an inexpensive and compact integrated PM2.5 mass and AOD sampler known as the Solar-Powered Aerosol Reference Calibrator (SPARC). PM2.5 is …

    colostate Repository record for A low-cost monitor for simultaneous measurement of fine particulate matter and aerosol optical depth (opens in a new tab)

  14. Simultaneous measurement of ion ratios by inductively coupled plasma - mass spectrometry with a twin quadrupole instrument

    … multiplier. Thus, ion ratios can be measured simultaneously without scanning. Isotope ratios for copper are measured with a precision of 0.14% relative standard deviation (RSD). Internal standard ratios for (Co+ signal)/(La+ signal) are measured with a precision of 1% RSD. Ion signals in the …

    iastate Repository record for Simultaneous measurement of ion ratios by inductively coupled plasma - mass spectrometry with a twin quadrupole instrument (opens in a new tab)

  15. The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point

    … outside the boundary layer adjacent to the gage. Simultaneous monitoring of these signals allowed the time-resolved documentation of the effects of local freestream turbulence on boundary layer heat transfer. The resulting time traces indicate a direct correlation between the turbulent velocity …

    vt Repository record for The simultaneous measurement of time-resolved surface heat flux and freestream turbulence at a stagnation point (opens in a new tab)

Page 1 of 17