Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results 1 to 7 of 7 for “"single energy computed tomography"”
-
Optimization of Computed Tomography Calibration Curve for Proton Therapy Treatment Planning
… improvement in determining proton SPR using single energy computed tomography (SECT) to reduce the uncertainty in predicting the proton range in patients. Factors which may cause CT number variations in the calibration curve have been examined. The HU-SPR calibration curve was determined …
-
Identification of Intracranial Lesions With Dual-Energy Computed to mography and Magnetic Resonance Phase Imaging
On conventional Single-energy Computed Tomography (SECT), lesions with an attenuation greater than 100 Hounsfield Units (HU) can be definitively diagnosed as calcification. However, low-density calcifications and hemorrhage may have overlapping attenuation ranges between 40 and 100 HU and, …
-
Performance Evaluation of Material Decomposition Using Rapid Kvp-Switching Dual-Energy Ct For Assessing Bone Mineral Density
… and has previously been characterized with dual-energy x-ray absorptiometry (DXA) or single-energy computed tomography (SECT). Dual-energy computed tomography (DECT) is able to create two three-dimensional sets of images representing the densities of two materials in a given basis pair. DECT is …
-
Basis Vector Model Method for Proton Stopping Power Estimation using Dual-Energy Computed Tomography
… is the stoichiometric calibration method using single-energy computed tomography (SECT) images, which in principle may introduce large intrinsic uncertainties into estimation results. One major factor that limits the performance of SECT-based methods is the Hounsfield unit (HU) degeneracy in the …
-
Validating Internal Density Calibration in The Proximal Humerus to Estimate Bone Stiffness Using Finite Element Analysis for Stemless Shoulder Arthroplasty
… density (vBMD) from greyscale intensity in computed tomography (CT) images, but this method is rarely used in clinical practice due to limited time and resources. As a result, alternative density measures for determining accurate vBMD from clinical CT images are needed. Internal density …
-
Imaging Techniques for Proton Range Determination in Proton Therapy
… to map SPR from Hounsfield Unit (HU) values of a single-energy computed tomography (SECT) scan through a stoichiometric calibration technique. This technique is subjected to a variety of factors that congregate on the uncertainties in SPR estimation, including the calibration uncertainty (up to …