Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 10 of 10 for “"single shot imaging"”

  1. Design and Optimization of a Stacked Three-Layer X-ray Detector for Multi-Spectral Medical Imaging Applications

    Dual-Energy (DE) imaging is a powerful technique in x-ray imaging that increases the ability to detect specific materials in a cluttered background, and is used to more accurately visualize anatomical features and diagnose abnormalities. Single-shot imaging has arisen as one of the dominant …

    waterloo Repository record for Design and Optimization of a Stacked Three-Layer X-ray Detector for Multi-Spectral Medical Imaging Applications (opens in a new tab)

  2. Development of instantaneous temperature imaging in sooty flames.

    This dissertation reports on the single-shot temperature imaging in sooty flames, based on the development of two-line atomic fluorescence (TLAF), with neutral Indium atom as seeded thermometry species. The TLAF technique in the linear excitation regime has previously been demonstrated to be …

    adelaide Repository record for Development of instantaneous temperature imaging in sooty flames. (opens in a new tab)

  3. Exploring methods for imaging dynamics in transmission electron microscopy

    … used to image and the noise generated by the imaging devices. In this thesis we explore methods of accessing time-resolved information from a JEOL ARM200cF - "MagTEM" through use of the active pixel sensor (APS) detector Medipix3 capable of single electron counting and noise-free readout. …

    glasgow Repository record for Exploring methods for imaging dynamics in transmission electron microscopy (opens in a new tab)

  4. Development of Non-Linear Laser-Based Imaging Techniques for Diagnostics of Reactive Flows

    … development of advanced non-linear laser-based imaging methods to achieve such diagnostics with improved spatial and temporal precision. A primary challenge in laser diagnostics is the detection of short-lived radicals, such as atomic oxygen (O), which plays a critical role in combustion and …

    lund Repository record for Development of Non-Linear Laser-Based Imaging Techniques for Diagnostics of Reactive Flows (opens in a new tab)

  5. Digital Holographic Microscopy for High-throughput Analysis of Tumour Cells

    visible, and in time-lapse imaging, light levels can be harmful for cells. These routines can affect the behaviour of cells and introduce unwanted artefacts in the captured images. Digital holographic microscopy(DHM)enables stain-free single-shot imaging of living cells, uses low light intensities, …

    maynooth Repository record for Digital Holographic Microscopy for High-throughput Analysis of Tumour Cells (opens in a new tab)

  6. Development and application of photofragmentation laser-induced fluorescence for visualization of hydrogen peroxides

    … laser-induced fluorescence can be used for imaging, line measurements as well as for point measurements, and it can provide high temporal and spatial resolution. Experimental investigations have been carried out in free flows of gas phase H2O2/H2O/N2/O2 mixtures, in an industrial test rig as …

    lund Repository record for Development and application of photofragmentation laser-induced fluorescence for visualization of hydrogen peroxides (opens in a new tab)

  7. Shot noise, refractive index tomography and aberrations estimation in digital holographic microscopy

    … microscopy (DHM), namely the effect of shot noise on the phase image accuracy, the use of DHM in micro-tomography and in aberrations evaluation of a microscope objective (MO). DHM is an imaging technique, allowing to measure quantitatively the wavefront transmitted through or reflected …

    epfl Repository record for Shot noise, refractive index tomography and aberrations estimation in digital holographic microscopy (opens in a new tab)

  8. Towards near-atomic resolution imaging of microsecond nanoscale dynamics

    … of temporal resolution, atomic-resolution imaging of nanoscale dynamics has remained elusive. This thesis describes the development of two methods for time-resolved electron microscopy which afford near-atomic spatial resolution. The first consists of a modification of a commercial …

    epfl Repository record for Towards near-atomic resolution imaging of microsecond nanoscale dynamics (opens in a new tab)

  9. Patient-specific prospective respiratory motion correction in cardiovascular MRI.

    … allowing for highly efficient free-breathing imaging. However, these techniques are generally applied with a generic tracking factor to correlate a respiratory signal to the position of the heart, and do not adequately represent the patient and respiratory phase-specific motion of the heart. …

    ohiolink Repository record for Patient-specific prospective respiratory motion correction in cardiovascular MRI. (opens in a new tab)

  10. Time-Resolved Transmission Electron Microscopy: Instrumentation and Applications

    In recent decades, in situ electron microscopy has attracted considerable attention. The method enables real time observations of the transformations of nanoparticles under various stimuli with atomic spatial resolution. Time-resolved electron microscopy adds a new dimension, time, to such …

    epfl Repository record for Time-Resolved Transmission Electron Microscopy: Instrumentation and Applications (opens in a new tab)