Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 54 for “"single-shear"”.
-
Single shear vs. double shear for nails in lateral loading
… the lateral load-carrying capacity of nails in single and double shear, and (2) to develop a basis for structural design data for laterally loaded nails in double shear applicable whenever deformation is a governing factor, such as in joints of trussed rafters. The test loads at or near …
-
Capacity Resistance and Performance of Single-Shear Bolted and Nailed Connections: An Experimental Investigation
… of physical data characterizing the behavior of single-shear, laterally-loaded connections when loaded up to and beyond capacity (i.e., maximum resistance). Specimens included a wide array of connection configurations common in wood construction. All connections were tested monotonically in …
-
Evaluating the Bond Behavior Between FRP and Grooved Concrete Specimens Using Single Shear Pull Out Test
… surface and in the grooves. To execute the test, single shear pull out test is conducted under which all the specimens are tested. Results from the test reveal that F specimens are 77% stronger than C specimens. This finding points to the fact that filled specimens possess extra strength due to …
-
The Effects of Bolt Spacing on the Performance of Single-Shear Timber Connections Under Reverse-Cyclic Loading
Much previous experimentation related to wood structures has employed monotonic loading to replicate static situations. However, instances of natural hazards have raised interest in the response of structural connections to dynamic loads. This increased interest led the Consortium of Universities …
-
Investigation of the Effects of Spacing between Bolts in a Row in a Single-Shear Timber Connection Subjected to Reverse Cyclic Loading
… if spacing between bolts in a multiple-bolt, single-shear connection subjected to natural hazard loading affects seven strength and serviceability parameters: maximum load, failure load, E.E.P. yield load, 5% offset load, elastic stiffness, E.E.P. energy, and ductility ratio. This research …
-
Comparing Sandwich Wall Panel Shear Connector Testing Methodologies
… rapid construction, and thermal efficiency. Shear connectors are used to connect the two wythes of concrete to allow composite action of the system. In order to design concrete sandwich panel systems to act compositely, the engineer must obtain design values from a connector manufacturer, …
-
The Effect of Cycling Moisture Content on the Lateral Load Carrying Capacity of Three Member Nailed Wood Joints
… Douglas fir plywood. Nails were placed in single shear and double shear with the two sizes of splice plates. Nail sizes were 6d bright common, 8d bright common, and 8d bright ring shank. Specimens with various combinations of splice plate thickness and nail sizes were constructed with …
-
The load deformation response of single bolt connections
… response of bolted connections. The behavior of single bolt, single shear connections are studied. Seventy tests with different configurations were conducted to evaluate their failure mechanisms and load-deformation characteristics. Comparisons to previous study were made. A new analytical model …
-
High pressure LOx/H₂ rocket engine combustion.
… injection conditions which was performed with a single shear coaxially injected liquid rocket engine combuster. Steady state operation was closely examined with the thrust chamber operating at sub critical, near critical and supercritical pressure levels with respect to the thermodynamic critical …
-
Study of deformation-induced structures in a Zr-based bulk metallic glass via high energy x-ray diffraction
… BMG, and residual strain around a single shear band. 1. Strain evolution during in-situ compression The structural rearrangements occurring during compressive deformation of a plastically deformable BMG showed that the elastic and plastic deformation of the BMG is correlated to the …
-
Advanced Analysis of Cold-Formed Steel Portal Frames Having Semi-rigid Joints
… finite element analysis. CFS portal frames with single channel and back-to-back channel sections are two popular structures in industrial and housing applications. Single shear joints are used in the single channel portal frames and with tilting failure of the fasteners. For the back-to-back …
-
Further Investigation of a New Traction Stress Based Shear Strength Characterization Method with Test Data
… traction stress based method for characterizing shear strength is investigated by carrying out a series of shear strength tests. The AWS method for the calculation of shear strength shows significant discrepancies between longitudinal and transverse specimens. The main purpose of this new …
-
Cold-Formed Steel Bolted Connections without Washers on Oversized and Slotted Holes
… The bearing failure of sheet and the shear failure of sheet were considered in this study. For the sheet shear strength, it was found that the NASPEC (2007) design provisions can be used for oversized holes in both single and double shear configurations and for the double shear …
-
An Experimental Study of Novel Cold Worked Penetrative Reinforcement of GFRP/ Aluminium Bonded Joints
… the properties of this technology employed on a single shear lap joint is investigated to determine ultimate strength, fatigue performance, impact fatigue, and finally failure modes under different surface configurations. Use of a novel tumbling method to test impact fatigue is developed and test …
-
Thermo-mechanical response of monolithic and NiTi shape memory alloy fiber reinforced Sn-3.8Ag-0.7Cu solder
… fatigue life of the solder during both single and multiple thermal cycling under double-shear loading. For comparison, thermo-mechanical single shear tests were also performed in monolithic Tin- Silver-Copper solder and in solder reinforced with Cu fiber. Also, micro-structural …
-
Experimental Investigation of Group Action Factor for Bolted Wood Connections
… factor at the 5% offset yield and capacity of single-shear bolted wood connections loaded parallel to grain. The single and multiple-bolt connections tested represent common connection geometries used in wood construction in the United States. The results of both monotonic and cyclic loading of …
-
Strengthening of arched masonry structures with composite materials
… along the interface, a far-end supported single shear test was modified and adapted. Monotonic load was applied to the FRP strip until failure was attained. To determine the anchor length where the failure mode changed from sliding to tensile failure in the FRP strip, different anchorage …
-
Experimental investigation of shear transfer between concrete interfaces
… was focused on the effect of surface geometry (shear keys) on the transmission of shear forces between concrete cast against a hardened concrete interface. This research was part of a larger study at The University of Texas at Austin focused on several aspects of spliced precast concrete girder …
-
Seismic Behaviour and Ductility Evaluation of multi-storey Light timber-frame Buildings by Means of analytical Formulations and numerical Modelling
… and nonlinear behaviour of light timber-frame shear-walls buildings (called Platform Frame); in the first part the analysis of the linear-elastic behaviour is presented, whereas in the second part the non-linear behaviour is considered. After a short introduction on the state of the art of …
Page 1 of 3