Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 72 for “"skimmer"”.

  1. Computer Program for Two Shaft Skimmer Design

    … chain pulls and shaft sizes for two-shaft skimmer mechanisms. Such skimmers are used on scum concentrators and flotation thickening equipment. These mechanisms fit into the process stream of wastewater treatment plants, both municipal and industrial. Included are sample runs, program …

    marquette Repository record for Computer Program for Two Shaft Skimmer Design (opens in a new tab)

  2. Evaluating the Effectiveness of the Skimmer Versus the Perforated Riser in Sedimentation Basins

    … However, a relatively new outlet device, the skimmer, has been developed, which dewaters the basin from the water surface. A laboratory study was conducted to compare the skimmer with the perforated riser for three different soil types and determine if there were any significant differences in …

    vt Repository record for Evaluating the Effectiveness of the Skimmer Versus the Perforated Riser in Sedimentation Basins (opens in a new tab)

  3. Fundamental studies of the plasma extraction and ion beam formation processes in inductively coupled plasma mass spectrometry

    … Langmuir measurements in the region between the skimmer and first ion lens. Electron temperature (T e) is in the range 2000-11000 K and changes with probe position inside an aerosol gas flow. Electron density (n e) is in the range 108-1010 cm-3 near the skimmer tip and drops abruptly to 106-108 …

    iastate Repository record for Fundamental studies of the plasma extraction and ion beam formation processes in inductively coupled plasma mass spectrometry (opens in a new tab)

  4. A "heat pipe"-style recirculating lithium oven for entrainment into supersonic helium beams

    … beam can be further collimated by using a skimmer. Two different heat-pipe oven designs are investigated in this thesis, one for entrainment downstream of the skimmer and on for entrainment upstream of the skimmer. Downstream of the skimmer, the lithium that is carried in the helium beam …

    texas Repository record for A "heat pipe"-style recirculating lithium oven for entrainment into supersonic helium beams (opens in a new tab)

  5. Case study of a flowfield using a pentode

    … for nitrogen and carbon dioxide. Placement of a skimmer between the pentode and nozzle provided the means by which a certain portion of the plume could be observed, but the skimmer also produced the possibility of shock interference. The gauge was used to characterize the flowfield, and the axial …

    ut-knoxville Repository record for Case study of a flowfield using a pentode (opens in a new tab)

  6. Two Studies on Controlling the Outflow from Sediment Basins: 1) Developing Discharge Coefficients for Circular Orifices in Round Riser Pipes, and 2) Optimizing the Solid State Skimmer

    … retention basin when using a Solid State Skimmer. It was determined that the true area of a circular orifice cut into a round riser pipe is greater than the normally assumed area, area of the bit that cut the orifice, and that flow rate varied because of the unique shape formed by the cut. …

    ut-knoxville Repository record for Two Studies on Controlling the Outflow from Sediment Basins: 1) Developing Discharge Coefficients for Circular Orifices in Round Riser Pipes, and 2) Optimizing the Solid State Skimmer (opens in a new tab)

  7. Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer

    … behaviors of analyte through the sampling and skimmer cones will provide the insights needed to alleviate matrix interferences and to improve the interface design between the ICP and mass spectrometer. Laser induced fluorescence is a highly sensitive, non-invasive and element specific detection …

    byu Repository record for Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab) Download PDF for Ion Transport Behaviors Upstream and Downstream from the Sampling Cone of an Inductively Coupled Plasma Mass Spectrometer (opens in a new tab)

  8. Reducing Effluent Phosphorus And Nitrogen Concentrations From A Stormwater Detention Pond Using A Chamber Upflow Filter And Skim

    … Florida using a Chamber Upflow Filter and Skimmer (CUFS), which can increase the removal of phosphorus and nitrogen by the system. Water enters the system through the skimmer, which floats on the surface of the detention pond. It travels from the skimmer to the bottom of the chamber, where …

    ucf Repository record for Reducing Effluent Phosphorus And Nitrogen Concentrations From A Stormwater Detention Pond Using A Chamber Upflow Filter And Skim (opens in a new tab)

  9. The development and evaluation of small specialized turtle excluder devices to reduce sea turtle bycatch in various small shrimp gears

    In the southeastern United States, skimmer trawls, pusher-head trawls, wing nets, and small try nets (headrope length less than 12-ft (3.66-m)) are exempt from using a turtle excluder device (TED) and instead must adhere to tow time restrictions as a mode to mitigate sea turtle bycatch. However, …

    uno Repository record for The development and evaluation of small specialized turtle excluder devices to reduce sea turtle bycatch in various small shrimp gears (opens in a new tab)

  10. Ecological correlates of protein polymorphisms in a desert and non-desert population of Belonia saturata (Odonata: Anisoptera)

    Two populations of the Big Red Skimmer Dragonfly, Belonia saturata (Odonata: Amisoptera), were studied to determine the thoracic temperatures maintained during flight, the presence of polymorphic enzyme systems, and to determine the differences in activity of glycerol-3-phosphate dehydrogenase …

    csusb Repository record for Ecological correlates of protein polymorphisms in a desert and non-desert population of Belonia saturata (Odonata: Anisoptera) (opens in a new tab)

  11. Ecological correlates of protein polymorphisms in a desert and non-desert population of Belonia saturata (Odonata: Anisoptera)

    Two populations of the Big Red Skimmer Dragonfly, Belonia saturata (Odonata: Amisoptera), were studied to determine the thoracic temperatures maintained during flight, the presence of polymorphic enzyme systems, and to determine the differences in activity of glycerol-3-phosphate dehydrogenase …

    csusb-retro Repository record for Ecological correlates of protein polymorphisms in a desert and non-desert population of Belonia saturata (Odonata: Anisoptera) (opens in a new tab)

  12. Calibration, optimization, and deployment of PTR-MS instruments during the AIRMAP project

    … chamber. The PTR-MS uses a differentially pumped skimmer to prevent excess water from the ion source from entering the drift tube reaction chamber. By placing a metering valve in between the skimmer region and the pump, it was possible to control the amount of water entering the drift tube. The …

    unh-thes Repository record for Calibration, optimization, and deployment of PTR-MS instruments during the AIRMAP project (opens in a new tab)

  13. Development of a numerical model of a two-dimensional inertial gas separator

    … expansion fan was able to attach to the first skimmer and began the formation of a supersonic beam. This caused the skimmer to not act as a sonic throat when the supersonic inner core of the barrel shock that was formed in the first chamber maintained its velocity through the skimmer throat. …

    wvu Repository record for Development of a numerical model of a two-dimensional inertial gas separator (opens in a new tab)

  14. Mass spectrometry in shock tunnels

    … contamination in a free piston shock tunnel. A skimmer, which formed a molecular beam that was ionised and analysed by a quadrupole mass spectrometer, sampled the flow. The design and construction of the vacuum system, the ion source, and the mass spectrometer are discussed. The response time of …

    anu Repository record for Mass spectrometry in shock tunnels (opens in a new tab)

  15. Enhancement of ion transmission and reduction of background and interferences in inductively coupled plasma mass spectrometry

    … SIMION show that only those ions that leave the skimmer on center are transmitted, whereas most other lenses used in ICP-MS transmit only ions that leave the skimmer off axis. The performance of a Channeltron electron multiplier is compared to that of a Daly detector. Both detectors yield similar …

    iastate Repository record for Enhancement of ion transmission and reduction of background and interferences in inductively coupled plasma mass spectrometry (opens in a new tab)

Page 1 of 4