Dynamic Analysis of Slab-on-Grade Systems: Forward and Backcalculation Analyses
The problem of calculating the response of a slab-on-grade is of interest for analysis and design of industrial floors, nuclear plants, mat and raft foundations, and pavement systems. These structures are often subjected to complicated external dynamic excitations such as earthquakes, impacts, and …
-
Analysis of Slab-on-Grade Floors Subject to Slab-Mounted Jib Cranes
Free-standing, foundationless jib cranes mounted directly on unreinforced slab-on-grade floors are a common necessity in industrial settings for material handling purposes. Ensuring that existing slabs can support a jib crane is critical, as industrial floors are subject to stringent serviceability …
-
Materially Nonlinear Finite Element Analyses of Trusses and Slab-on-Grade Problems
… is to employ the finite-element method along with specified material models to account for material nonlinearity. This study includes two different applications: truss structures and slabs-on-grade. Procedures for materially nonlinear analysis of truss structures, which apply for both …
-
Analysis of slab-on-grade pavement systems subjected to wheel and temperature loadings
This study is focused on the analysis of slab-on-grade pavement systems. Temperature and wheel loadings are considered. Aggregate interlock and dowel bars may be taken into account as load transfer devices at the joints or cracks.
-
Experiments Designed to Evaluate Insulating Schemes for Slab-on-Grade Hydronic Radiant Floor Heating
Common slab-on-grade insulating design practices for Hydronic Radiant Floor Heating (HRFH) vary anywhere from using only vertical insulation completely along the outdoor perimeter, complete vertical insulation and under-floor insulation a short distance in from the outdoor perimeter, and complete …
-
Shrinkage Cracks in Concrete Structures - Comparison of Design Methods for Slab-on-Grade Foundations
Abstract Shrinkage cracks in reinforced concrete slabs-on-grade foundations are in most projects di cult to limit, despite that the design is carried out according to codes and recommendations. The current Eurocode can be interpreted in several ways regarding shrinkage cracks which results in that …
-
Estimating structural design parameters for slab-on-grade supported residential and light commercial structures from fundamental soil moisture changes
… States, Austraha, Africa and the Middle East (Donaldson, 1969). The distribution of expansive soils in the United States and throughout the world are shown in Figs. 1-1 and 1-2. Clayey soils with this shrink-sweU potential cause many problems in engineering stmctures, such as canal linings, …
-
Minimizing the Climate Impact of Slab-on-Grade Foundations Through Life Cycle Analysis: Considering energy performance and material use across different building types and material configurations
While it is commonly perceived that increasing insulation thickness improves performance by reducing heat loss through the foundation, this also increases material use and environmental impact. In parallel, interest in alternative foundation materials has grown, driven by the need to reduce …
-
Feasibility and implementation of automation and robotics in Canadian building construction operations
Includes a case study of automation of concrete slab-on-grade construction.
-
A Data Acquisition System for 300 Quasi-grounded Thermocouples
… 310 thermocouples were installed in and under a slab-on-grade concrete floor. During the installation two irregularities were introduced; the thermocouple junctions were constructed from extension grade thermocouple wire and the welded thermocouple junctions were placed in direct electrical …
-
Give that building C.P.R.! : bringing life back into flooded mid-century modern residences
… the way we must approach historic preservation practices for the future. The Mid-Century Modern housing stock of Houston, TX is among the nation’s largest and has been continuously threatened by severe flooding in recent years. Between 2015-2017, approximately 30 percent of the Mid-Century …
-
Parametric Study of Traffic Induced Ground Vibrations due to Heavy Vehicles
Due to recently imposed building regulations the demands of sound exposure levels to buildings have changed, allowing urban planners to design residential areas in direct proximity to roads and railways. While the Swedish building code requires for a risk evaluation regarding comfort vibrations …
-
Comparative Heat Load Analysis for a Direct Gain Passive Solar Building
A newly erected University Police Safety Building on the campus was constructed with passive solar design features. The slab-on-grade brick building has 3081 square feet of conditioned space, an ample south-facing solar aperture with clerestory and an air-to-air heat pump system. A comparative …
-
Ground-coupled heat and moisture transfer from buildings
A two-dimensional finite element heat and moisture transfer computer program and a companion two-dimensional heat transfer computer program were developed to study the ground-coupled heal transfer from buildings. Ground-coupled heat transfer can account for over 50% of the heat loss from a well …
-
Performance of surface structures subjected to subsurface soil erosion
… engineering structures (e.g. pavements, slabs-on-grade, footings) transfer pressure to the ground through a contact area with the supporting soil. Design of these structures usually assumes that full contact is established throughout the service life of the structure. Erosion of the …
-
Engineered Fibre-reinforced Concrete Systems for Bridge Deck Link Slab Applications
Rehabilitation and maintenance of the aging transportation infrastructure are of major concern in the Province of Ontario. A large portion of this work is related to the durability of highway bridges around the province. One of the weakest points in a bridge structure from a durability aspect is …
-
Tapered plate dowels for jointed concrete slabs
Submission original under an indefinite embargo labeled 'Open Access'. The submission was exported from vireo on 2024-03-01 without embargo terms
-
Specialized fiber reinforced concretes under static and impact loading
… test method to characterize the energy absorption capacity (toughness) of fiber reinforced concrete (FRC). Traditional beam flexural tests provide toughness assessment only under small deflections. This has not reflected the reality of most FRCs applied in slab-on-grade and tunnel/mine projects, …
-
Active zone depth and edge moisture variation distance in expansive soils
Two fundamental design parameters for foundations on expansive soils are historically referred to as active zone depth and edge moisture variation distance. The purpose of this research was to investigate these two parameters in terms of their historical definitions, characterize them in terms of …