Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 73 for “"slice thickness"”.
-
A Study of Imaging Techniques of 3-Dimennsional CT Diagnosis for Rib Fractures
… investigate the appropriate techniques including slice thickness and increment intervals for reconstructing 3D CT images in the diagnosis of rib fractures. From the raw CT data of 30 patients who were admitted to our emergency department due to blunt chest trauma and performed thoracic …
-
Effect of Time and Steroids Administration on Radiation Targets in Canine Extra-Axial Brain Tumors
… time delay is likely due to the significant slice thickness difference between MRI acquisitions. This finding highlights the different requirements between diagnostic and RT planning MRIs. For brain tumor target contouring, an MRI at the same time as the RT planning CT with <1 mm slice …
-
An Automated Ultrasound Calibration Framework Incorporating Elevation Beamwidth for Tracked Ultrasound Interventions
… further reduced by the "elevation beamwidth" or "slice thickness", a unique feature of the ultrasound beam pattern that gives rise to localization errors and imaging uncertainties. In this thesis, we aim to provide an automated, pure-computation-based, intraoperative calibration solution that also …
-
Radiomic Estimation of Geometric Metrics of Bone Microstructure: Comparison of Ultra-High and Normal-Resolution CT
… resolution (NR) CT. Using UHR MDCT (0.25 mm slice thickness), NR MDCT (0.5 mm slice thickness), and micro-CT (50 µm voxel size), we captured six human femora images and extracted 129 spherical ROIs (10 mm) aligned spatially via rigid registration. Twenty-four Gray Level Co-occurrence Matrix …
-
Evaluation of the Normal Equine Pituitary Gland
… scanned using 10x10mm, 10x5mm, 4x4mm and 4x2mm slice thickness and interval combinations. The pituitary glands were removed immediately after CT and gross measurements were performed. CT measurements were compared with gross pituitary measurements using analysis of variance (ANOVA) in a …
-
Additive Manufacturing of Copper-based Alloy by Laser Powder Bed Fusion
… hatch spacing from 0.06mm to 0.21mm, and slice thickness of 0.03mm. Relative density of 98% to 100% by Archimedes Principle and nearly 100% by image analysis were obtained for a large range of parameters for Cu10Sn samples, which shows a very good printability of Cu10Sn over a large window …
-
Fabrication and Testing of a Microchannel Network Phantom for MRI Velocimetry
… of velocity near the channel edges. Slice thickness, order of image acquisition, partial volume effects, and acceleration effects are investigated, and show little effect on the measured flow rates. Examination of anatomical MR images show that the channels decreased in height during …
-
Low Dose Computed Tomography Reconstruction Methods
… controls one of these factors. Increasing the slice thickness increases the number of detected X-ray photons, thereby reducing the image noise. However, it also reduces the detectability and measurement accuracy of the small structures. An optimum slice thickness/overlap for low dose …
-
Development of shrinkage drying model for prediction of changes in quality indicators during drying of fruits and vegetables
… and tested for heat pump dryer using cylindrical slices of banana and carrot, which were dried as single layer. Shrinkage and drying data were collected for banana slices (approximately 5 to 9 mm) over a range of drying conditions from 28°C-38°C and 12-30 % relative humidity. Experiments for …
-
MORPHOMETRIC ANALYSIS OF THE SHEEP THORACOLUMBAR SPINE USING COMPUTED TOMOGRAPHY AND A COMPARISON WITH THE HUMAN CORRELATE
… CT images were reformatted with 1-mm slice thickness from T2 through L6. The CT images were reformatted in transverse and sagittal planes using multiplaner reconstruction algorithm. Subsequently, CT images were transferred to a workstation and reviewed with dedicated software for …
-
Feasibility Study of Low Dose Chest CT for Initial Evaluation of Blunt Chest Trauma Patient
… saggital images were reconstructed with 3-mm slice thickness without gap for investigators. Reference standard images (transverse, coronal, saggital) were reconstructed using standard chest CT data with 1-mm slice thickness without gap. Reference standard was established by 2 experienced …
-
Estudo da secagem do pedúnculo do caju em sistemas convencional e solar: modelagem e simulação do processo
… temperature, air velocity control and cashew slice thickness of 55°C, 65°C, 75°C; 3.0; 4.5, 6.0 m s-1; 1.0; 1.5 and 2.0 cm, respectively, in order to compare the studied systems. To evaluate the conventional tray-dryer, it was used a diffusional model of 2nd Fick´s law, where the drying curves …
-
The relevance of CT densitometry decline in never and ex-smokers with alpha one antitrypsin deficiency (AATD) and chronic obstructive pulmonary disease (COPD); a systematic review and validation study in untreated patients
… software program, reconstruction algorithm and slice thickness were meta-analysed. The variability the two leading software programs, PULMO and Pulmonary Workstation was calculated, and showed that where the same slickness and reconstruction algorithms were used, the two programs showed directly …
-
Radiotherapy Dose Calculation Algorithm Sensitivity To High-Density Artifacts
… CT scanner set to a 16-bit scale with a 0.9 mm slice thickness and 0.45 mm overlap slice to minimize voxel averaging differences at the location of the clip. A radiotherapy plan was created using a virtual tumor emulating a 1 cm diameter soft tissue tumor with the surgical clip at the center. …
-
Static and dynamic imaging using magnetic field gradients = Jingtai yu dongtai heci chengxiang : a thesis presented in partial fulfilment of the requirements for the degree of Master of Science in Physics at Massey University
… A transverse resolution of 15 µm for a 1 mm slice thickness is obtained from a static imaging experiment of a phantom using the modified system. The rabbit trachea imaging experiment has revealed the asymmetrical collapse of tracheas under negative pressures, a collapse which had previously …
-
Uniform framework for the objective assessment and optimisation of radiotherapy image quality
… radiographs (DRRs), a reduction in CT slice thickness resulted in an expected improvement in MTF in the patient scanning direction but a deterioration in the orthogonal direction, with the optimum slice thickness being 1–2 mm. Two general purposes display devices were calibrated against …
-
Avaliação da composição corporal por tomografia computadorizada: achados clínicos e relevância de parâmetros técnicos de aquisição de imagens
… which may hinder methodological standardization. Slice thickness is one of the parameters that may influence BC measurements. Patients with colorectal cancer (CRC) often present alterations in BC that are associated with poorer clinical outcomes. However, many studies analyze colon and rectal …
-
Characterization of metal artifacts in diffusion tensor imaging for spinal cord applications
… techniques including view-angle-tilting, slice thickness, and field of view size. Minor reduction in metal artifact was achieved using these techniques. The resulting image data shows that imaging near metal may be feasible in some circumstances, particularly when implantation is minimal. …
-
Ο ρόλος του συνδυασμού αξονικής και μαγνητικής τομογραφίας στη βελτίωση της προεγχειρητικής σταδιοποίησης στον καρκίνο του παχέος εντέρου
… in a 128 row multidetector (MD) CT scanner (slice thickness: 1mm) with intravenous contrast. Pathology report was considered as the gold standard for local staging. Sensitivity (SE), specificity (SP), and area under the curve (AUC) were calculated for both observers. MRI displayed a higher …
Page 1 of 4