Relationship between the Sludge Settling Characteristics and the Parameters of the Activated Sludge System
The activated sludge process is one of the most commonly employed domestic and industrial waste treatment process. Different types of mathematical models have been proposed for design and operation of this process, most of which do not consider the relationship between the sludge settling …
-
Exocellular Polymeric Substances, Bioflocculation and Sludge Settling Properties in a Combined Anaerobic/Activated Sludge Process
… of organic, nutrient substances and reduction of sludge produced. Previous studies developed at the Marrero Wastewater pilot plant (fully aerobic system) revealed that the minimum solids contact chamber hydraulic residence (HRT) time in which bioflocculation occurs satisfactorily (effluent SS …
-
Change in sludge settling and filtration properties and membrane fouling trends in MBR activated sludge systems operated at different solids and hydraulic retention times
Membrane bioreactor (MBR) activated sludge process is increasingly used in wastewater treatment due to its excellence in solid-liquid separation and superior effluent quality, smaller bioreactor volume and foot print. However, operational issues such as membrane fouling and sludge bulking affect …
-
The role of biopolymers in thickening and dewatering of activated sludge
… examine the relationship between biopolymer and sludge settling and dewatering properties. The biopolymer that interfered with sludge filtration was a high molecular weight (>10⁵) anionic biocolloid composed partially of proteins, carbohydrates and humic acids. The relationship between …
-
The effect of varying several operational parameters on the dewatering characteristics of activated sludge
… parameters and their effect on activated sludge settling and dewatering rates. Several laboratory scale reactors were used in this study and fed with various synthetic substrates. The sludges produced from these reactors were used to examine sludge settling and dewatering characteristics …
-
The effects of dissolved oxygen concentration on the kinetics and settleability of activated sludge
… coefficient and settleability of activated sludge. Synthetic substrate loadings of 0.25, 0.50, 0.75 were applied to bench scale activated sludge reactors with average mixed liquor volatile suspended solids concentrations of 2000 mg/1. The substrate removal rate coefficient, oxygen uptake …
-
Destruction of cadmium cyanide waste by alkaline chlorination treatment
<p>Sludge characteristics and supernatant quality were studied in laboratory scale tests on alkaline chlorination treatment of cadmium cyanide solutions. Jar tests were conducted at pH values ranging from 7 to 11, utilizing two forms of hypochlorites as oxidants. In addition, synthetic solutions …
-
Reduced domestic water use
… Demands (COD) of up to 1500 mg/1 using activated sludge was investigated with both bench scale batch and continuous processes. Specific items investigated as functions of waste concentration included substrate removal rates, oxygen uptake rates, aeration properties, sludge settling, sludge …
-
The influence of cations on activated sludge behavior
… of cations on biopolymer characteristics and sludge properties. Settling and dewatering properties of sludges were measured and correlated to the biopolymer characteristics. In addition, effects of cations on sludge conditioning with polymer were studied. Experiment mainly consisted of two …
-
The influence of nitrogen and sludge age change in reactor performance and biopolymer production in activated sludge
… study investigated the influence of nitrogen and sludge age change in reactor performance and biopolymer production in activated sludge systems. The qualitative and quantitative analyses of the naturally occurring biopolymers were performed and the results were correlated to sludge a settling …
-
A Comparison Of Aluminum And Iron-based Coagulants For Treatment Of Surface Water In Sarasota County, Florida
… less effective than ACH at removing organics. Sludge settling curves, dose-sludge production ratios, and settling velocities were determined at optimum DOC removal conditions for each coagulant. Ferric chloride was found to have the highest sludge settling rate but also produced the largest …
-
Effects of holding tank odor control chemicals on aerobic wastewater treatment
… were tested for detrimental affects on activated sludge using bench-scale bioreactors. Slug fed and continuous flow bioreactors were monitored for changes in suspended solids, specific oxygen uptake rate, sludge settling and compaction, and effluent COD. The biodegradability of dyes and the …
-
Effects of varying environmental conditions on performance of completely autotrophic nitrogen removal from dewatered sludge liquors
… the reactor could be effectively controlled by sludge settling time. Sludge settling times between 4 to 10 min were recommended, for achieving purposes of sludge enrichment or system optimization.
-
Attached growth nitrification using Ringlace media
… at tested DO concentrations above that. Sludge settling in the test process improved over the control process during a run with 6 hour HRT, 4 day SRT, 5.5 mg/L DO level, and 18 °C temperature. During this run the control process average specific nitrification rate was 2 mg-N/gTSS-hr and …
-
Bioflocculation in EBPR Process Operated at Short Sludge Retention Times
Activated sludge processes operated at short sludge retention time (SRT) offer potential to reduce the energy requirement for biodegradation while maximizing the conversion of biodegradable organic matter into the biomass for energy recovery. However, concern has been raised with poor sludge …
-
The aerobic treatment of reverse osmosis permeate for reuse : a thesis submitted in partial fulfilment of the requirements for the degree of Master of Technology in Environmental Engineering
… efficiency. Operation of a model activated sludge pilot plant showed that soluble COD removal efficiencies of over 90% could be achieved at hydraulic retention times of 10 and 20 hours. The sludge settling characteristics were more favourable at a 10 hour hydraulic retention time. Sudden …
-
Laboratory evaluation of microbial aggregation in activated sludge
… investigated in this study using the activated sludge process as a model system, the performance of which is highly dependent on effective bioaggregation. This research includes two experiments. First, four laboratory-scale activated sludge sequencing batch reactors (SBRs) were constructed in …
-
Sensitivity Analysis of the UNO Activated Sludge Model
… have been proposed to predict the activated sludge process final effluent quality. La Motta (2004b) developed a mathematical model linking the operating parameters of an activated sludge system and the classical limiting flux sludge settling theory. This project studies the estimation of the …
-
Effects of microwave irradiation on the characteristics and mesophilic anaerobic digestion of sequencing batch reactor sludge
… treatment generates large quantities of sewage sludge whose disposal is expensive. Mainly because anaerobic digestion produces methane, which can be beneficially used as an energy source, this process has become the most popular means of stabilizing sewage sludge prior to spreading on …
-
Development of Scale Factors for Clarifier Design Based on Batch Settling Data
Traditionally, batch settling tests have been employed to determine the values of the settling parameters V0 and K of the Vesilind equation which represents activated sludge settling velocity as a function of solids concentration. It remains unresolved how closely batch settling tests describe …