Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 27 for “"soft start"”.

  1. Simulation of 3-Phase 3-Level Flying Capacitor rectifier with soft start and flying capacitor voltage balancing

    … However, pre-charging flying capacitors during startup and ensuring the balance of flying capacitor voltage during operation are crucial to managing stress on switches. These tasks add complexity to control and, if not handled correctly, can destroy the converter. This thesis aims to address the …

    texas Repository record for Simulation of 3-Phase 3-Level Flying Capacitor rectifier with soft start and flying capacitor voltage balancing (opens in a new tab)

  2. Schrumpfungsverhalten von Kompositen bei Aushärtung mit unterschiedlichen Polymerisationsgeräten bzw. -verfahren in vitro

    … im Vergleich zu Standard Halogenlampen und Soft-Start Verfahren. Zu diesem Zweck wurde die Polymerisationsschrumpfung mit der von Watts & Cash (1991) beschriebenen Deflecting Disk Technique gemessen. Die Konversionsrate wurde indirekt über die Härtemessung nach Knoop bestimmt, die nach 24 …

    wurz-thes Repository record for Schrumpfungsverhalten von Kompositen bei Aushärtung mit unterschiedlichen Polymerisationsgeräten bzw. -verfahren in vitro (opens in a new tab)

  3. Korrelationen antagonistischer Materialeigenschaften dentaler Komposite und der Vergleich unterschiedlicher Belichtungskonzepte

    … Es stellte sich dabei heraus, dass mittels der Soft-Start-Polymerisation für flache Kavitäten von 2 mm mit Hochleistungs-LEDs geringere Schrumpfspannungen erzeugt werden können, bei gleichzeitig konstanten Werten der mirkomechanischen Eigenschaften sowie der Konversionsrate. Die Verzögerung des …

    lmu-germany Repository record for Korrelationen antagonistischer Materialeigenschaften dentaler Komposite und der Vergleich unterschiedlicher Belichtungskonzepte (opens in a new tab)

  4. Microcontroller (MCU) Based Simplified Optimal Trajectory Control (SOTC) for High-Frequency LLC Resonant Converters

    … dynamics, burst mode for light-load efficiency, soft start-up and short circuit protection. Additionally, digital controllers are gradually taking the place of analog controllers in the control of the LLC resonant converter due to the advantages of the digital controllers over the analog …

    vt Repository record for Microcontroller (MCU) Based Simplified Optimal Trajectory Control (SOTC) for High-Frequency LLC Resonant Converters (opens in a new tab)

  5. Pavaros su dažnio keitikliu valdymo sistema /

    … is transmitted through designed gear. Motor soft start, stop, and speed regulation performs the frequency converter. Control can be manual buttons and from the PC. The analytical part of an overview of the topic related to contemporary educational system. There were a few well-known …

    vilnius Repository record for Pavaros su dažnio keitikliu valdymo sistema / (opens in a new tab)

  6. Composite cure and post-gel shrinkage with different halogen and LED curing lights

    … continuous (FL1, EL2, TL1), turbo (EL3, AS1) and soft-start (FL2, EL4, TL2) modes of various lights were also investigated. The thermal emission of LED lights was significantly lower than halogen lights. For all lights, effectiveness of cure was found to decrease with increasing cavity depths. All …

    nus Repository record for Composite cure and post-gel shrinkage with different halogen and LED curing lights (opens in a new tab) Download file for Composite cure and post-gel shrinkage with different halogen and LED curing lights (opens in a new tab)

  7. Soft Started Induction Motor Modeling and Heating Issues for Different Starting Profiles Using a Flux Linkage ABC-Frame of Reference

    Starting of induction machines cause torque transients, high inrush currents, and thus heating of the machine. A popular method for starting an induction machine is applying electronically controlled soft starting voltages using series connected silicon controlled rectifiers (SCRs). A flux linkage …

    marquette Repository record for Soft Started Induction Motor Modeling and Heating Issues for Different Starting Profiles Using a Flux Linkage ABC-Frame of Reference (opens in a new tab)

  8. Development And Parameter Refinement Of A Dynamic Simulation Model Of A Fixed Speed Stall Control Wind Turbine Under Start-Up Conditions

    … and verified with existing field data under start up conditions. Model components include the wind, the turbine rotor and generator, soft-start power electronics and controls, and the distribution grid. PSCAD/EMTDC (Power Systems Computer Aided Analysis and Design/Electromagnetic Transients …

    nodak Repository record for Development And Parameter Refinement Of A Dynamic Simulation Model Of A Fixed Speed Stall Control Wind Turbine Under Start-Up Conditions (opens in a new tab)

  9. Two-Stage Multi-Channel LED Driver with CLL Resonant Converter

    … special electrical characteristics of LED, the soft start-up process with a delayed dimming signal is adopted and investigated. With the soft start-up, there is no overshoot for the output current. Finally, a prototype of the two-stage LED driver is built. The current balance capability of the …

    vt Repository record for Two-Stage Multi-Channel LED Driver with CLL Resonant Converter (opens in a new tab)

  10. Decentralized control of grid-connected cascaded AC-DC converters with integrated battery energy storage

    … The fourth proposes a decentralized soft-start method for a cascaded H-bridge and quad-active-bridge based medium-voltage ac-dc converter, limiting inrush during start-up and grid connection. Together, these works show that scalable, robust, and communication-free coordination of …

    texas Repository record for Decentralized control of grid-connected cascaded AC-DC converters with integrated battery energy storage (opens in a new tab)

  11. Design and construction of a hybrid vehicle driveline Developed for an ECO-marathon car

    … directly connected to a super capacitor with a soft start in between to be able to connect them in a smooth way. By doing this, the generators are also used as a start engine. The drive motor is also a brushed DC-motor connected to the super capacitor via a converter. All parts of the test bench …

    chalmers Repository record for Design and construction of a hybrid vehicle driveline Developed for an ECO-marathon car (opens in a new tab)

  12. An Isolated Micro-Converter for Next-Generation Photovoltaic Infrastructure

    … in the 250-W prototype. Chapter 4 considers the soft-start of the proposed system, which can have a very large capacitive load from the inverter. A new capacitor-transient limited (CTL) soft-start method senses the ac transient across the resonant capacitor, prematurely ending the lower switch …

    vt Repository record for An Isolated Micro-Converter for Next-Generation Photovoltaic Infrastructure (opens in a new tab)

  13. Modeling and control of a high power soft-switched bi-directional DC/DC converter for fuel cell applications

    … derived to design a control system that achieves soft start up and meets the performance requirements. The second part is to fabricate a 1.6 kW prototype converter in the laboratory. Using the prototype, the steady state performance of the open loop system was tested to verify the analysis and …

    utk-theses Repository record for Modeling and control of a high power soft-switched bi-directional DC/DC converter for fuel cell applications (opens in a new tab)

  14. A High-Efficiency Hybrid Resonant Microconverter for Photovoltaic Generation Systems

    … applications are explored. The first issue is soft start, which is necessary when the converter is beginning operation with a large capacitive load. A novel soft start method is introduced that allows the converter to start up safely and quickly, even with a short-circuited output. Maximum …

    vt Repository record for A High-Efficiency Hybrid Resonant Microconverter for Photovoltaic Generation Systems (opens in a new tab)

  15. Design, modeling and control of a 12.47 kV isolated three phase power factor correction rectifier

    … state machine, including I/O management, soft start-up strategy and system protection scheme, is designed to promote the overall design close to the industrial product. The soft start-up strategy effectively limits the inrush current and charges the output DC bus from zero to full energy …

    texas Repository record for Design, modeling and control of a 12.47 kV isolated three phase power factor correction rectifier (opens in a new tab)

  16. The transputer control of induction motor drives

    … matrix operations. The use of such a specialized software package provided a 'user-friendly' operating environment with error messages identifying problem areas during program development. The resulted computer model of the drive system offers high flexibility and modularity and can be readily …

    southwales Repository record for The transputer control of induction motor drives (opens in a new tab) Download PDF for The transputer control of induction motor drives (opens in a new tab)

  17. Very High Efficiency Bridgeless Boost Totem-Pole PFC using Gallium Nitride HEMTs

    … MOSFETs to achieve ideal diode emulation, a soft-start function during the zero-crossings of the line voltage to reduce AC current spikes, a fast voltage control loop for better dynamic performance, and two heatsink designs to reduce GaN switch temperatures during high load operation. …

    queens Repository record for Very High Efficiency Bridgeless Boost Totem-Pole PFC using Gallium Nitride HEMTs (opens in a new tab)

  18. Realization of a High Power Microgrid Based on Voltage Source Converters

    … before final prototyping of the inductor. A start-up control algorithm is important for a high power ac-dc converter, otherwise inrush current caused by the dc capacitor bank may trigger over current protection, induce system oscillation, or even result in a system collapse. The reason of …

    arkansas Repository record for Realization of a High Power Microgrid Based on Voltage Source Converters (opens in a new tab)

  19. Improving the safety operation of three-phase shunt active filter

    … shunt active filter operation is analyzed for soft start and stop mechanism. The proposed filter uses a nonlinear current control algorithm developed to generate the reference currents of the active filter. The theoretical considerations are verified by simulation using Power System Blockset of …

    ets-quebec Download PDF for Improving the safety operation of three-phase shunt active filter (opens in a new tab)

  20. State-Trajectory Analysis and Control of LLC Resonant Converters

    … dynamic processes like the load transient, start-up, over-load protection and burst operation, it is hard to control the current and voltage stresses and oscillations in the resonant tank. Moreover, to meet the high power density requirement, the LLC is required to operate at a high …

    vt Repository record for State-Trajectory Analysis and Control of LLC Resonant Converters (opens in a new tab)

Page 1 of 2