Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 91 for “"solid contact"”.
-
Liquid-solid contact phenomenon in film boiling of Leidenfrost drops
… heating surface intermittently come into direct contact with the liquid, thus providing a possible means of enhancing the heat transfer in film boiling. Transient surface temperature measurements obtained from the flush-mounted micro-thermocouples demonstrated that direct contact between the …
-
Miniaturizable Ion-Selective Electrode System: Solid Contact Electrode and Liquid Junction Free Reference Electrode
… have an interior solution that forms a liquid contact with a selective membrane. However, complications due to evaporation and freezing in certain circumstances lead to irreproducibility, instability of the signals, and shortened life expectancy. In addition, miniaturization is an obstacle for …
-
Performance improvement of solid contact ion-selective electrodes: towards sensors with high reproducibility and stability
… and later recalibration, are highly desirable. Solid-contact ion-selective electrodes have been an area of significant research in these efforts to develop sensors which can fulfill these needs of high reproducibility and stability. One category of solid-contact ion-selective electrodes are …
-
Development and Characterization of Solid-Contact Paper-Based and Micro Ion-Selective Electrodes for Environmental Analysis
… this work will also highlight the benefits of solid-contact ISEs, specifically focusing on two solid- contact platforms: 1) paper-based and 2) a micro-electrode platform. Paper-based based sensors were designed to be used as a possible diagnostic tool to be implemented in undeveloped countries …
-
Solid-contact potassium ion-selective electrodes with plasticizer-free silicone-based membranes for extended potassiumiIon monitoring in physiological samples
… like those in wearable or implantable devices. Solid-contact ion-selective electrodes (SC-ISEs) in direct contact with physiological samples for long-term measurements must be biocompatible and resistant to biofouling.Silicone ISEs are a promising alternative to plasticized PVC because of their …
-
Development and characterization of ion-selective electrodes based on laser-induced graphene for food safety and precision agriculture
… The second chapter is a review and tutorial of solid-contact ISEs. LIG is used as the solid-contact to investigate the relationship between solid-contact surface properties and the resulting electrochemical properties. The concepts and techniques discussed are applicable to any solid-contact …
-
Controlling Architecture and Composition of Nanostructured, Multicomponent Materials for Applications in Sorption, Energy Storage, and Sensing
… surfaces with a Co(II/III) redox buffer as a solid contact was developed with the goal to ultimately prepare calibration-free solid-contact ion-selective electrode. The Co(II/III) redox buffer was covalently attached to the carbon substrate by grafting a terpyridine ligand (Tpy-ph), followed …
-
The effects of the Thunderstick batting device on hitting efficiency
… efficiency will be defined as the degree of solid contact made by the performer when attempting to hit a baseball. It was the intention of Coach Al Endriss (1986) to invent a hitting aid that would not only increase the amount of solid contact by his players, but also produce less strikeouts …
-
Highly Reproducible Electrochemical Sensors towards Wearable Applications and Pharmaceutical Analysis
… Among the two different platforms of ISEs (solid-contact and liquid-contact), solid-contact ISEs are superior to ISEs with internal electrolytes (liquid-contact) since they are easy to be miniaturized, can be used in any environment and their portability is facilitated. Unfortunately, mass …
-
Calibration-free ion-selective electrodes and theoretical insights and practical applications of ionic liquid references
… and colloid-imprinted mesoporous (CIM) carbon as solid contact (Ch. 3), and the third is the theoretical study of the limit of application of the ionic liquid reference electrodes (Ch. 4). Potentiometric sensors, including ISEs and reference electrodes, represent a significant segment of the field …
-
Ion-Sensing Systems Based on Mesoporous Carbon: from Bulk Electrodes to Paper-Based Ion Sensors
… affordable and portable analytical devices, all-solid-state ISEs and reference electrodes, in which a solid contact is used as an ion-to-electron transducer, are highly desirable. Compared with conventional ISEs, all-solid-state ISEs offer comparable electrochemical performance with the distinct …
-
Droplet friction on heterogeneous surfaces
The ability to control friction between a solid and a liquid is becoming more and more important in various existing applications as well as in novel ones. However, the mechanisms behind this liquid-solid friction are not yet sufficiently understood. This thesis compiles research performed in three …
-
Nanomechanics, Nanotribology and Surface Interactions of Ultra Thin Films
… of different thin film applications in terms of contacts between the surfaces at different temperatures and environmental conditions. Three types of contact conditions were considered in this study- solid-solid contact for hard coatings, solid-solid contact for soft coatings and solid-liquid …
-
Au@Pt Core-Shell Nanoparticles as Solid Contacts in Ion Selective Electrodes for Ammonium Detection
… The proposed ion-selective electrode contains solid contact instead of internal solutions as is the case for conventional ion selective electrodes. This property of the proposed electrode makes it smaller and maintenance-free.So far, different kinds of material have been used as solid contacts …
-
Heat and mass transfer in pulsed fluidized bed of biomass
… was selected as an indirect indicator of gas–solid contact, heat and mass transfer. Mass transfer was evaluated through batch drying tests, where better gas–solid contact and mass transfer was assessed through the water removal efficiency. An optimum operating condition was identified after …
-
Heat transfer model of the hot rolling runout table-cooling and coil cooling of steel
… of the nucleation process, fluid flow, liquid-solid contact area, and the liquid-vapor interface instability allow succesful prediction of pilotplant and full-scale operations and of the most fundamental microscopic parameters measured elsewhere. The liquid-solid contact found in the transition …
-
Modélisation des conditions d’apparition du micro-hydrodynamisme via la méthode des éléments finis dans la perspective d’intégrer ce phénomène dans un modèle numérique de laminage à froid.
… scale leading to a lubrication of the tool-piece solid contacts and therefore to a local friction drop. For instance, Laugier et al. have observed a friction decrease while rolling High Strength Steels for different strip thickness reductions. The only physical explanation to this trend is the MPH …
-
ELECTROLYTE AND INTERFACE DESIGNATION FOR HIGH-PERFORMANCE SOLID-STATE LITHIUM METAL BATTERIES
… attention due to its significant impact on the solid electrolyte interphase (SEI) and the Li metal plating/stripping behaviors. Compared to the traditional liquid electrolytes, solid-state lithium metal batteries (SSLMB) have been regarded as the holy grail, the future of electric vehicles …
-
Jet Impingement Heat Transfer from Superheated, Superhydrophobic Surfaces
… Water droplets are known to bead up upon contact with superhydrophobic (SH) surfaces. This is due to reduced surface attraction caused by micro- or nanostructures that, combined with a natively hydrophobic surface chemistry, reduce liquid-solid contact area and attraction, promoting …
-
SOLUTION EXPLORATION OF AN ATOMICALLY-SPACED HEAD-DISK INTERFACE FOR MAGNETIC DISK DRIVE APPLICATION
… STATE BETWEEN INTERMITTENT LUBRICANT CONTACT AND SOLID CONTACT, REQUIRES ATOMICALLY SMOOTH INTERFACE. DISCOVERY OF THE SURFING REGIME PUSH THE
Page 1 of 5