Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 16 of 16 for “"sonomicrometry"”.
-
Developing procedures and software for correcting artifacts in motion data
… techniques for obtaining such recordings are sonomicrometry and optical marker-based motion capture. Although commonly used, sonomicrometry and motion capture are often limited by the presence of artifacts that require correction. Unfortunately, the standard approach to artifact correction in …
-
Angiogenesis and Myogenesis in a Chronic Ischemic Heart.
… + Laser TMR+ Cells; Group 4, Ischemia + Cells. Sonomicrometry and Millar pressure transducers were used to determine contractility, left ventricular pressure, and pressure-volume loops. There were no significant differences (p<0.05)among the hemodynamic data except for Group 4, which produced …
-
Image-based geometric modeling of patient-specific human tricuspid valve
… in-situ measurements of annular dynamics via sonomicrometry and measurements on leaflet geometries via photos of human valves. This work is the first step towards a finite element model of patient-specific, human tricuspid valves that will aid in our understanding of normal and abnormal valve …
-
Direct and Indirect Measurement of the Effects of Halothane and Isoflurane on Arterial Wall Mechanics
… are compared to those made simultaneously by sonomicrometry. The finite element model enables the corresponding electric field to be determined. A study of the effects of halothane and isoflurane on direct measurements of canine aortic pressure-volume and pressure diameter relations in vivo is …
-
Evidence for Transcapillary Movement of Exogenous Superoxide Dismutase and Catalase into Dog Myocardium
… SOD and CAT exert their effect. As measured by sonomicrometry, reperfusion injury was reduced by SOD and CAT in these preparations within one minute of reperfusion. Reperfusion was followed by intracoronary fixation. Using transmission electron microscopy, electron dense material was observed in …
-
Η επίδραση της παραορτικής αντλίας αντιώθησης (PULVAD) στη στεφανιαία ροή και στη ροή στις καρωτίδες σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… Pigs were instrumented with Millar catheter, sonomicrometry crystals and a Doppler flow probe placed around LAD and common carotid artery. Coronary and carotid blood flow were measured without and after brief (<60 secs) PULVAD support during reperfusion. Results: While PULVAD support decreased …
-
Respiratory Muscle Function with Agonists
… shown after flaccid paralysis using sonomicrometry. Physiological data, both in its collection and analysis, requires skill and great care as to avoid bias and to maintain integrity and honesty in its reporting. The analysis process from beginning to end is a cornerstone of this …
-
Η επίδραση της υποβοήθησης με παραορτική αντλία αντιώθησης (PULVAD) στους δείκτες συστολικής και διαστολικής λειτουργίας της αριστεράς κοιλίας σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας
… kg) were instrumented with Millar catheter, sonomicrometry crystals and a Doppler flow probe placed around the left anterior descending artery (LAD). Pigs underwent PULVAD implantation and induction of acute heart failure by LAD ligation for 60 minutes, followed by reperfusion. PULVAD was …
-
Impact of Torsion on Left Ventricular Flow for Normal and Stressed Heart Conditions Based on Echocardiography-CFD Framework
… to the LV endocardium, a technique known as sonomicrometry. The simulation results are validated against intracardiac flow velocity measured by Doppler ultrasound. To assess the impact of torsion, two baseline simulations (one with torsion and one without with similar ejection fraction) are …
-
Impact of Torsion on Left Ventricular Flow for Normal and Stressed Heart Conditions Based on Echocardiography-CFD Framework
… to the LV endocardium, a technique known as sonomicrometry. The simulation results are validated against intracardiac flow velocity measured by Doppler ultrasound. To assess the impact of torsion, two baseline simulations (one with torsion and one without with similar ejection fraction) are …
-
Impact of Torsion on Left Ventricular Flow for Normal and Stressed Heart Conditions Based on Echocardiography-CFD Framework
… to the LV endocardium, a technique known as sonomicrometry. The simulation results are validated against intracardiac flow velocity measured by Doppler ultrasound. To assess the impact of torsion, two baseline simulations (one with torsion and one without with similar ejection fraction) are …
-
Impact of Torsion on Left Ventricular Flow for Normal and Stressed Heart Conditions Based on Echocardiography-CFD Framework
… to the LV endocardium, a technique known as sonomicrometry. The simulation results are validated against intracardiac flow velocity measured by Doppler ultrasound. To assess the impact of torsion, two baseline simulations (one with torsion and one without with similar ejection fraction) are …
-
Development of an ex vivo pulsatile heart model of functional mitral regurgitation to facilitate posterior papillary muscle geometric studies and subvalvular surgical strategy
… the underlying LV remodeling was not treated. Sonomicrometry was used to evaluate the three-dimensional tethered distances and tethered angles of the PPM due to regional LV dilatation. The findings of this study implied that although annular dilatation was normalized, the increased PPM …
-
Mechanisms of coordination between one- and two-joint synergist muscles
… to analyze kinematics and joint moments, sonomicrometry was used to measure muscle fascicle length in cats, and electromyography (EMG) was used to quantify muscle activity. Length-velocity related sensory feedback was removed in cats by muscle self-reinnervation. Results show that …
-
Muscle mechanics and hydrodynamics of jet propulsion swimming in marine invertebrates
… range in body mass. Power was measured using sonomicrometry crystals to measure muscle length changes during swimming whilst pressure was simultaneously monitored within the mantle cavity. The scaling of the contractile characteristics of the adductor muscles of scallops was investigated to …
-
Neural Respiratory Drive and Respiratory Muscle Function During CO2 Stimulation
Background. The use of EMG of the respiratory muscles as a surrogate of the central neural respiratory drive is gaining clinical popularity. Currently, the clinical EMG recording of the crural diaphragm by an esophageal electrodes probe (EAdi) is promoted as a “gold standard”. Additionally, other …