Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 21 for “"special moment frames"”.

  1. Flexural demand of columns in Special Moment Frames

    … the flexural demand distribution (bending moment diagram) shape, and the moment distribution at beam-column joints. Incremental dynamic analysis (IDA) was carried out for a 15-story special moment frame subjected to 20 different ground motions. A newly developed demand-chain concept was …

    iastate Repository record for Flexural demand of columns in Special Moment Frames (opens in a new tab)

  2. Performance Prediction and Evaluation of Steel Special Moment Frames for Seismic Loads

    … panel zone deformation and interior gravity frames. The 1973 UBC, 1985 UBC and 1994 UBC provisions were selected for the pre-Northridge 3-, 9- and 20-story buildings in Los Angeles and Seattle and designed for wind and seismic loads. A total of 15 pre-Northridge buildings, which are …

    uiuc Repository record for Performance Prediction and Evaluation of Steel Special Moment Frames for Seismic Loads (opens in a new tab)

  3. Performance of concrete Special Moment Frames during Mainshock-Aftershock sequences with varying dominant frequency ranges of ground motions

    … The study specifically looks at concrete Special Moment Frames as the lateral force-resisting system. Five sequences were included in the study varying either the stiffness of the structure or the frequencies of the earthquakes. The structural damage was quantified by plastic hinge …

    texas Repository record for Performance of concrete Special Moment Frames during Mainshock-Aftershock sequences with varying dominant frequency ranges of ground motions (opens in a new tab)

  4. Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification

    Special moment frames having specially detailed connections are common in high seismic regions, providing architectural flexibility for passageways and views without brace obstructions. In situations where the building framing layout requires deviation from typical rectangular framing, skew in the …

    arkansas Repository record for Experimental Design and Preliminary Testing for Skewed Special Moment Frame Prequalification (opens in a new tab)

  5. Cyclic Testing of a Skewed Special Moment Frame RBS Connection Having a Composite Concrete Slab

    Special moment frames (SMFs) having reduced beam section (RBS) connections are commonly used in high seismic areas as they resist lateral forces while preserving critical welded connection regions. RBS SMFs provide brace-free, unobstructed frame options which can be favorable for architectural …

    arkansas Repository record for Cyclic Testing of a Skewed Special Moment Frame RBS Connection Having a Composite Concrete Slab (opens in a new tab)

  6. Response of Cyclically Loaded Extended End-Plate Moment Connections When Used With Welded Built-Up Sections

    … to study the behavior of extended end-plate moment connections subjected to cyclic loading. Eleven specimens were tested, representing typical connection configurations used in the metal building manufacturing industry. Four of the beams were shallow (30 in. or less), and seven were deep (60 …

    vt Repository record for Response of Cyclically Loaded Extended End-Plate Moment Connections When Used With Welded Built-Up Sections (opens in a new tab)

  7. Performance-Based Analysis of a Reinforced Concrete Shear Wall Building

    … BUILDING Garrett Richard Hagen In this thesis, a special reinforced concrete shear wall building was designed per ASCE 7-05, and then the performance was investigated using the four analysis procedures outlined in ASCE 41-06. The proposed building was planned as a 6-story office building in San …

    calpoly Repository record for Performance-Based Analysis of a Reinforced Concrete Shear Wall Building (opens in a new tab)

  8. Analytical Development of A Plastic Hinge Detail for Steel SMFs

    A modular plastic hinge seismic special detail has been developed for use in steel special moment frames (SMFs). The aim of the special detail design is to dissipate seismic energy through stable yielding of a beam "link" in plastic hinge region. Reliable and repeatable energy dissipation at high …

    arizona-thes Repository record for Analytical Development of A Plastic Hinge Detail for Steel SMFs (opens in a new tab)

  9. Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses

    Special moment frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs. SMFs provide lateral system stiffness without the use of braces that often obstruct views and architectural features. Current American Institute of Steel Construction (ASIC) provisions …

    arkansas Repository record for Cyclic Behavior of Laterally Skewed Special Moment Frame Connections: Experimental Testing and System-Level Analyses (opens in a new tab)

  10. Development and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connection

    Three end-plate moment connection configurations are prequalified for special moment frames for seismic applications in AISC 358-10. The eight bolt extended stiffened connection is the strongest of the three configurations, but it can only develop approximately 30 percent of currently available …

    vt Repository record for Development and Validation of a Twelve Bolt Extended Stiffened End-Plate Moment Connection (opens in a new tab)

  11. Effect of Beam Bracing on the Seismic Performance of Laterally Skewed Reduced Beam Section Moment Connections with Composite Concrete Slabs

    Existing experimental reduced beam section (RBS) moment frame investigations, particularly those used for prequalification in AISC-358, consider orthogonally oriented beam-to-column connections. While the design commentary provided in AISC-358 references recent skewed SMF numerical studies and …

    arkansas Repository record for Effect of Beam Bracing on the Seismic Performance of Laterally Skewed Reduced Beam Section Moment Connections with Composite Concrete Slabs (opens in a new tab)

  12. Seismic Loading Effects within Orthogonally Connected Steel Lateral Force Resisting Systems

    … within seismically active regions require special design considerations to ensure public safety and prevent collapse during an extreme seismic event. Two commonly used steel systems are special moment frames (SMFs) and buckling-restrained braced frames (BRBFs). When two seismic systems …

    arkansas Repository record for Seismic Loading Effects within Orthogonally Connected Steel Lateral Force Resisting Systems (opens in a new tab)

  13. Impact of seismic code provisions in the central U.S.: a performance evaluation of a reinforced concrete building

    … region. A four-story reinforced concrete (RC) moment frame with wide-module pan joists was designed according to current building codes relevant to the central U.S.: the 2003 IBC, the City of Memphis and Shelby County locally amended version of the 2003 IBC, and the 1999 Standard Building Code …

    tamu Repository record for Impact of seismic code provisions in the central U.S.: a performance evaluation of a reinforced concrete building (opens in a new tab)

  14. Experimental Evaluation of Replaceable Shear Fuse Moment Connections

    Steel special moment frames (SMFs) are known to be highly ductile seismic force- resisting systems. The performance of an SMF relies on the ability of the connections to accommodate large inelastic deformations. After the brittle failure of some steel moment frame connections during the 1994 …

    byu Repository record for Experimental Evaluation of Replaceable Shear Fuse Moment Connections (opens in a new tab)

  15. On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections

    Special Moment Frames (SMFs) are frequently used in high seismic areas for architecturally constrained designs, as they provide lateral system stiffness without the use of braces which often obstruct views and architectural features. Reduced beam section (RBS) connections are popular SMF connection …

    arkansas Repository record for On the Seismic Performance of Skewed Special Moment Frame Reduced Beam Section Connections (opens in a new tab)

  16. Evaluating the Fracture Potential of Steel Moment Connections with Defects and Repairs

    Steel moment frames are a popular seismic-force resisting system, but it is believed that they are susceptible to early fracture if there is a stress concentration in the plastic hinge region, also known as the protected zone. If a defect is present in this area, it may be repaired by grinding …

    vt Repository record for Evaluating the Fracture Potential of Steel Moment Connections with Defects and Repairs (opens in a new tab)

  17. ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS IN CONCRETE

    … hooked bars in tension in beam-column joints in special moment frames (Section 18.8.5.1 of ACI 318-19), derived from the development length provisions for non-seismic loading in earlier Codes, permit development lengths that are shorter needed for gravity load by Chapter 25. Changes in Chapter 18 …

    ku Repository record for ANCHORAGE OF HIGH-STRENGTH REINFORCING BARS IN CONCRETE (opens in a new tab)

  18. Influence of the Gravity System on the Seismic Performance of Special Steel Moment Frames

    … resisting system on the collapse performance of Special Steel Moment Frames (SMFs). The influence was quantified using the FEMA P-695 methodology. The buildings used for this study were a 2-, 4- and 8-story SMFs taken from the ATC76-1 project where their collapse performance was already evaluated …

    vt Repository record for Influence of the Gravity System on the Seismic Performance of Special Steel Moment Frames (opens in a new tab)

  19. Experimental and analytical investigation of panel zone behavior in steel moment frames

    Steel moment resisting frames (MRFs) are one of the most commonly used lateral force resisting system for steel building construction located in regions of high seismic risk. Although steel moment frames were studied extensively following the 1994 Northridge Earthquake, one critical design issue is …

    texas Repository record for Experimental and analytical investigation of panel zone behavior in steel moment frames (opens in a new tab)

  20. ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE

    … 3db between headed bars permitted in joints in special moment frames in accordance with Section 18.8.5.2 of ACI 318-14 to be reduced to 1db, allowing for the use of more closely spaced headed bars. The anchorage strength of the headed bars calculated using anchorage provisions of Chapter 17 of …

    ku Repository record for ANCHORAGE OF HEADED REINFORCING BARS IN CONCRETE (opens in a new tab)

Page 1 of 2