Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 25 for “"spectral Doppler"”

  1. Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound

    … by a clinical ultrasound scanner in duplex spectral Doppler mode at four pulse durations and four PRFs in a static fluid and in a flow system. Cavitation emissions from the UCAs insonified by Doppler pulses were recorded using a single-element passive cavitation detection (PCD) system and a …

    ohiolink Repository record for Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound (opens in a new tab)

  2. Ultrasound and magnetic resonance techniques for the haemodynamic quantification of the peripheral vascular system

    … way that blood flow velocities measured using spectral Doppler ultrasound are used to aid in the diagnosis of peripheral vascular disease. Specifically, we aimed to investigate the measurement of maximum velocities and the use of maximum velocity ratios; an area of investigation which has been …

    glasgow Repository record for Ultrasound and magnetic resonance techniques for the haemodynamic quantification of the peripheral vascular system (opens in a new tab)

  3. Cerebral and cardiac Doppler parameters in the identification of fetuses with late-onset intrauterine growth restriction at risk of adverse perinatal and neurobehavioral outcome

    Evaluation of fetal brain and cardiac Doppler parameters improves the identification of term, SGA fetuses with normal UA Doppler at risk of adverse perinatal outcome and abnormal neurobehavioral performance.<br/><br/>SPECIFIC HYPOTHESIS:<br/><br/>1. Cerebral blood perfusion is increased in SGA …

    barcelona Repository record for Cerebral and cardiac Doppler parameters in the identification of fetuses with late-onset intrauterine growth restriction at risk of adverse perinatal and neurobehavioral outcome (opens in a new tab)

  4. Evaluation of the Fetal Heart at 14 – 18 Weeks Gestation in Fetuses with a Screening Nuchal Translucency Greater than or Equal to the 95th Percentile

    … chart review, gray-scale images, Z-scores, and Doppler evaluation, including, pulsed, color and spectral Doppler, were reviewed to determine if the fetal heart evaluation at 14 – 18 weeks gestation were normal or abnormal. In this pre-experimental study, the sensitivity and specificity for …

    ohiolink Repository record for Evaluation of the Fetal Heart at 14 – 18 Weeks Gestation in Fetuses with a Screening Nuchal Translucency Greater than or Equal to the 95th Percentile (opens in a new tab)

  5. Assessment of blood velocity and wall shear rate in arteries with Doppler ultrasound: a validation study

    … include smoking, diet, and familial history. Doppler ultrasound can provide estimates of blood velocity and wall shear rate. Clinically, maximum velocity is used to categorise patients for surgery, although Doppler velocity measurement is prone to errors and in need of validation. Wall shear …

    edinburgh Repository record for Assessment of blood velocity and wall shear rate in arteries with Doppler ultrasound: a validation study (opens in a new tab)

  6. Atherosclerosis Plaque Neovascular Inflation Using Ultrasound Strain Imaging

    … relates the inflation with the PSVs measured by spectral Doppler. 22 carotid stenosis cases were studied and the results show that most carotid plaques inflate during cardiac cycle, and inflations correlate with PSV. The results provide encouraging evidence to the VV inflation hypothesis and pave …

    washington Repository record for Atherosclerosis Plaque Neovascular Inflation Using Ultrasound Strain Imaging (opens in a new tab)

  7. Towards Real-time Simulation of Ultrasound Systems

    … a three-phase approach, specifically to simulate spectral Doppler. In first place, it was shown that is possible to mechanistically simulate the sample volume power distribution using a novel method based on an array of point sources to represent the transducer geometry. Secondly, by comparison …

    toronto-retro Repository record for Towards Real-time Simulation of Ultrasound Systems (opens in a new tab)

  8. Flow mediated dilatation (FMD) assessment via an MRI integrated signal intensity (IntSI) approach: A comparison with ultrasound

    … of the popliteal artery were determined from spectral Doppler analysis, in order to design an in vivo technique that is compatible with the assumptions on which the IntSI technique is based. When applied in vivo, the IntSI technique overestimated luminal area measurements compared to a …

    toronto-retro Repository record for Flow mediated dilatation (FMD) assessment via an MRI integrated signal intensity (IntSI) approach: A comparison with ultrasound (opens in a new tab)

  9. Assessment of Mechanical and Hemodynamic Vascular Properties using Radiation-Force Driven Methods

    … flow velocity estimation techniques (color-flow Doppler and spectral-</p><p>Doppler imaging) with ARF-based elasticity characterization of vascular tissue. Techniques</p><p>for integrating B-mode, color-flow Doppler, and ARFI imaging were developed</p><p>(BACD imaging), validated in …

    duke Repository record for Assessment of Mechanical and Hemodynamic Vascular Properties using Radiation-Force Driven Methods (opens in a new tab)

  10. "Avaliação hemodinâmica da artéria testicular de garanhões normais e com torção do cordão espermático"

    Doppler ultrasonography is commonly used in andrological evaluation of humans and is a relevant method for monitoring testicular hemodynamics. However, in horse andrology it is scarcely used. Therefore, the aim of this study was to evaluate the blood flow pattern in testicular artery of normal …

    brazil-ufmg Repository record for "Avaliação hemodinâmica da artéria testicular de garanhões normais e com torção do cordão espermático" (opens in a new tab)

  11. Two-dimensional blood flow velocity estimation using ultrasound speckle pattern dependence on scan direction and velocity

    … has a comparable estimation performance to spectral Doppler with potential time savings. Finally, a two-dimensional blood flow velocity estimation algorithm using apparent speckle pattern angle was proposed in Chapter 7. The apparent angle of speckle pattern changes with different scan …

    nebraska Repository record for Two-dimensional blood flow velocity estimation using ultrasound speckle pattern dependence on scan direction and velocity (opens in a new tab)

  12. Aliasing-Free Maximum Velocity Estimation using Multi-angle Plane Wave Vector Flow Imaging

    … are typically measured using conventional spectral doppler ultrasound, which requires the operator to manually move a small sample volume to the relevant area and manually adjust a doppler angle. As a result, maximum velocity biomarkers can only be measured within a small portion of the …

    waterloo Repository record for Aliasing-Free Maximum Velocity Estimation using Multi-angle Plane Wave Vector Flow Imaging (opens in a new tab)

  13. Utilization of Musculoskeletal Sonography in Detecting Physiologic Changes of the Median Nerve in a Working Animal Model

    … representation of nerve size. Similarly, the spectral Doppler function possesses the capability of quantifying intraneural microvasculature within the median nerve, by obtaining peak systolic velocities (PSVs) throughout.These methods of using MSK sonography for early detection of symptoms …

    ohiolink Repository record for Utilization of Musculoskeletal Sonography in Detecting Physiologic Changes of the Median Nerve in a Working Animal Model (opens in a new tab)

  14. Ultrasound-Guided Analysis and Feedback Control for Blood Flow Management after Spinal Cord Injury

    … we termed the “penumbra.” In Chapter 3, we used spectral Doppler ultrasound to measured blood flow during dynamic changes in MAP in a naïve porcine spinal cord. We found differential effects of different drug types used to raise MAP. In Chapter 4, we used the insight from the previous two studies …

    jhu Repository record for Ultrasound-Guided Analysis and Feedback Control for Blood Flow Management after Spinal Cord Injury (opens in a new tab) Embargoed until 2030-05-01

  15. Mudanças no útero da égua após a infusão de fragmentos de conceptos

    … por palpação e ultrassonografia modo B e Doppler até o dia 7. Neste primeiro ciclo, liquido uterino e biopsias intrauterinas foram coletas no dia 7 após a ovulação, conformando o grupo Cíclico (n=10). No segundo ciclo, as mesmas éguas foram examinadas diariamente até detectar novamente a …

    brazil-ufrgs Repository record for Mudanças no útero da égua após a infusão de fragmentos de conceptos (opens in a new tab)

  16. Engineering a 3D ultrasound system for image-guided vascular modelling

    … blood flow patterns in the artery measured using spectral Doppler US. However other biomechanical factors such as wall shear stress (WSS) and areas of flow recirculation are also important in disease development and rupture. These are estimated using an image-guided modelling approach, where a …

    edinburgh Repository record for Engineering a 3D ultrasound system for image-guided vascular modelling (opens in a new tab)

  17. Correlação entre o tempo de aceleração plantar, o índice tornozelo braquial e os escores SVS-WIfI em pacientes com isquemia crônica ameaçadora do membro

    … in the world. A new diagnostic approach through Spectral Doppler analysis of the flow in the lateral plantar artery of the foot has shown correlation with the grade of the limb ischemia and amputation risk stages of the Wound, Ischemia, and foot Infection (WIfI) classification system and ABI. …

    brazil-ufmg Repository record for Correlação entre o tempo de aceleração plantar, o índice tornozelo braquial e os escores SVS-WIfI em pacientes com isquemia crônica ameaçadora do membro (opens in a new tab)

  18. Etude des caractéristiques globales des ondes de gravité atmosphérique à l'aide des mesures de vent du satellite de l'ESA Aeolus

    … la vitesse du vent par détection du décalage spectral Doppler de l'écho laser rétrodiffusé par les différentes couches atmosphériquesLes mesures de vent à l'échelle globale d'Aeolus seront d'une grande valeur pour l'étude des processus dynamiques dans la stratosphère. L'objectif principal de …

    star-france Repository record for Etude des caractéristiques globales des ondes de gravité atmosphérique à l'aide des mesures de vent du satellite de l'ESA Aeolus (opens in a new tab)

  19. Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients

    Keywords: Spectral Doppler imaging, peak systolic velocity, pulsatility index, vessel diameter, resistive index, nitrite, nitric oxide, systolic blood pressure, diastolic blood pressure.Objectives: i) To determine the repeatability of ultrasound parameters in measuring blood flow in diabetic …

    salford

  20. Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients

    Keywords: Spectral Doppler imaging, peak systolic velocity, pulsatility index, vessel diameter, resistive index, nitrite, nitric oxide, systolic blood pressure, diastolic blood pressure.Objectives: i) To determine the repeatability of ultrasound parameters in measuring blood flow in diabetic …

    salford Repository record for Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients (opens in a new tab)

Page 1 of 2