Results 1 to 20 of 25 for “"spectral Doppler"”
-
Relationship between loss of echogenicity and cavitation emissions from echogenic liposomes insonified by spectral Doppler ultrasound
… by a clinical ultrasound scanner in duplex spectral Doppler mode at four pulse durations and four PRFs in a static fluid and in a flow system. Cavitation emissions from the UCAs insonified by Doppler pulses were recorded using a single-element passive cavitation detection (PCD) system and a …
-
Ultrasound and magnetic resonance techniques for the haemodynamic quantification of the peripheral vascular system
… way that blood flow velocities measured using spectral Doppler ultrasound are used to aid in the diagnosis of peripheral vascular disease. Specifically, we aimed to investigate the measurement of maximum velocities and the use of maximum velocity ratios; an area of investigation which has been …
-
Cerebral and cardiac Doppler parameters in the identification of fetuses with late-onset intrauterine growth restriction at risk of adverse perinatal and neurobehavioral outcome
Evaluation of fetal brain and cardiac Doppler parameters improves the identification of term, SGA fetuses with normal UA Doppler at risk of adverse perinatal outcome and abnormal neurobehavioral performance.<br/><br/>SPECIFIC HYPOTHESIS:<br/><br/>1. Cerebral blood perfusion is increased in SGA …
-
Evaluation of the Fetal Heart at 14 – 18 Weeks Gestation in Fetuses with a Screening Nuchal Translucency Greater than or Equal to the 95th Percentile
… chart review, gray-scale images, Z-scores, and Doppler evaluation, including, pulsed, color and spectral Doppler, were reviewed to determine if the fetal heart evaluation at 14 – 18 weeks gestation were normal or abnormal. In this pre-experimental study, the sensitivity and specificity for …
-
Assessment of blood velocity and wall shear rate in arteries with Doppler ultrasound: a validation study
… include smoking, diet, and familial history. Doppler ultrasound can provide estimates of blood velocity and wall shear rate. Clinically, maximum velocity is used to categorise patients for surgery, although Doppler velocity measurement is prone to errors and in need of validation. Wall shear …
-
Atherosclerosis Plaque Neovascular Inflation Using Ultrasound Strain Imaging
… relates the inflation with the PSVs measured by spectral Doppler. 22 carotid stenosis cases were studied and the results show that most carotid plaques inflate during cardiac cycle, and inflations correlate with PSV. The results provide encouraging evidence to the VV inflation hypothesis and pave …
-
Towards Real-time Simulation of Ultrasound Systems
… a three-phase approach, specifically to simulate spectral Doppler. In first place, it was shown that is possible to mechanistically simulate the sample volume power distribution using a novel method based on an array of point sources to represent the transducer geometry. Secondly, by comparison …
-
Flow mediated dilatation (FMD) assessment via an MRI integrated signal intensity (IntSI) approach: A comparison with ultrasound
… of the popliteal artery were determined from spectral Doppler analysis, in order to design an in vivo technique that is compatible with the assumptions on which the IntSI technique is based. When applied in vivo, the IntSI technique overestimated luminal area measurements compared to a …
-
Assessment of Mechanical and Hemodynamic Vascular Properties using Radiation-Force Driven Methods
… flow velocity estimation techniques (color-flow Doppler and spectral-</p><p>Doppler imaging) with ARF-based elasticity characterization of vascular tissue. Techniques</p><p>for integrating B-mode, color-flow Doppler, and ARFI imaging were developed</p><p>(BACD imaging), validated in …
-
"Avaliação hemodinâmica da artéria testicular de garanhões normais e com torção do cordão espermático"
Doppler ultrasonography is commonly used in andrological evaluation of humans and is a relevant method for monitoring testicular hemodynamics. However, in horse andrology it is scarcely used. Therefore, the aim of this study was to evaluate the blood flow pattern in testicular artery of normal …
-
Two-dimensional blood flow velocity estimation using ultrasound speckle pattern dependence on scan direction and velocity
… has a comparable estimation performance to spectral Doppler with potential time savings. Finally, a two-dimensional blood flow velocity estimation algorithm using apparent speckle pattern angle was proposed in Chapter 7. The apparent angle of speckle pattern changes with different scan …
-
Aliasing-Free Maximum Velocity Estimation using Multi-angle Plane Wave Vector Flow Imaging
… are typically measured using conventional spectral doppler ultrasound, which requires the operator to manually move a small sample volume to the relevant area and manually adjust a doppler angle. As a result, maximum velocity biomarkers can only be measured within a small portion of the …
-
Utilization of Musculoskeletal Sonography in Detecting Physiologic Changes of the Median Nerve in a Working Animal Model
… representation of nerve size. Similarly, the spectral Doppler function possesses the capability of quantifying intraneural microvasculature within the median nerve, by obtaining peak systolic velocities (PSVs) throughout.These methods of using MSK sonography for early detection of symptoms …
-
Ultrasound-Guided Analysis and Feedback Control for Blood Flow Management after Spinal Cord Injury
… we termed the “penumbra.” In Chapter 3, we used spectral Doppler ultrasound to measured blood flow during dynamic changes in MAP in a naïve porcine spinal cord. We found differential effects of different drug types used to raise MAP. In Chapter 4, we used the insight from the previous two studies …
-
Mudanças no útero da égua após a infusão de fragmentos de conceptos
… por palpação e ultrassonografia modo B e Doppler até o dia 7. Neste primeiro ciclo, liquido uterino e biopsias intrauterinas foram coletas no dia 7 após a ovulação, conformando o grupo Cíclico (n=10). No segundo ciclo, as mesmas éguas foram examinadas diariamente até detectar novamente a …
-
Engineering a 3D ultrasound system for image-guided vascular modelling
… blood flow patterns in the artery measured using spectral Doppler US. However other biomechanical factors such as wall shear stress (WSS) and areas of flow recirculation are also important in disease development and rupture. These are estimated using an image-guided modelling approach, where a …
-
Correlação entre o tempo de aceleração plantar, o índice tornozelo braquial e os escores SVS-WIfI em pacientes com isquemia crônica ameaçadora do membro
… in the world. A new diagnostic approach through Spectral Doppler analysis of the flow in the lateral plantar artery of the foot has shown correlation with the grade of the limb ischemia and amputation risk stages of the Wound, Ischemia, and foot Infection (WIfI) classification system and ABI. …
-
Etude des caractéristiques globales des ondes de gravité atmosphérique à l'aide des mesures de vent du satellite de l'ESA Aeolus
… la vitesse du vent par détection du décalage spectral Doppler de l'écho laser rétrodiffusé par les différentes couches atmosphériquesLes mesures de vent à l'échelle globale d'Aeolus seront d'une grande valeur pour l'étude des processus dynamiques dans la stratosphère. L'objectif principal de …
-
Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients
Keywords: Spectral Doppler imaging, peak systolic velocity, pulsatility index, vessel diameter, resistive index, nitrite, nitric oxide, systolic blood pressure, diastolic blood pressure.Objectives: i) To determine the repeatability of ultrasound parameters in measuring blood flow in diabetic …
-
Duplex ultrasound assessment of early-stage peripheral artery disease in the lower limbs of Zimbabwean diabetic patients
Keywords: Spectral Doppler imaging, peak systolic velocity, pulsatility index, vessel diameter, resistive index, nitrite, nitric oxide, systolic blood pressure, diastolic blood pressure.Objectives: i) To determine the repeatability of ultrasound parameters in measuring blood flow in diabetic …
Page 1 of 2