Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 30 for “"spin echo sequence."”.

  1. Implementation of arbitrary trajectory fast spin-echo sequence on a memory-limited permanent magnet MRI scanner

    … more undersampling and artifact resistance. MRI sequences are typically developed to support a small number of hard-coded trajectories, but a more generalized approach would allow for rapid prototyping and greater flexibility, especially with the increasing popularity of low-field MRI …

    texas Repository record for Implementation of arbitrary trajectory fast spin-echo sequence on a memory-limited permanent magnet MRI scanner (opens in a new tab)

  2. Characterization of myelin water imaging using a gradient and spin echo sequence in human brain and spinal cord

    … a paradigm shift took place when the standard sequence for myelin water imaging changed from a multi-echo spin echo sequence to a gradient and spin echo (GRASE) sequence. The GRASE sequence has so far only been applied to brain imaging, and reproducibility between different scan vendors has not …

    ubc Repository record for Characterization of myelin water imaging using a gradient and spin echo sequence in human brain and spinal cord (opens in a new tab) Download PDF for Characterization of myelin water imaging using a gradient and spin echo sequence in human brain and spinal cord (opens in a new tab)

  3. ATOMIC OPTICS ANALOG OF THE PANCHARATNAM-BERRY PHASE

    … sensors utilizing what is called the spin-echo sequence. In 1956, Pancharatnam described the geometric phase difference between two polarized states of light. In 1984 Berry described the phase accrued in cyclic and adiabatic quantum systems. A Pancharatnam-Berry phase experiment …

    nps Repository record for ATOMIC OPTICS ANALOG OF THE PANCHARATNAM-BERRY PHASE (opens in a new tab)

  4. Magnetic Resonance Pulse Sequences for Fluorine-19

    … the necessary scanner modifications and pulse sequence adaptions. A ^(19)F/^(1)H dual tuned surface coil was purchased from RAPID Biomedical and was used throughout this work. Additionally, pulse sequence modifications to a spin echo sequence and a spoiled gradient echo (called fast low angle …

    tamu Repository record for Magnetic Resonance Pulse Sequences for Fluorine-19 (opens in a new tab)

  5. NMR measurement of diffusion in liquids by the pulsed field gradient technique

    … field gradient, technique is described. A 9-T-18 spin-echo sequence is used with one gradient pulse located on each side of the 18 rf pulse. Information on restricted diffusion is obtained by varying the measuring time, which is determined by the separation of the gradient pulse pair. Measuring …

    rice Repository record for NMR measurement of diffusion in liquids by the pulsed field gradient technique (opens in a new tab)

  6. The effect of hepatic fibrosis on T2 value in a mouse model at 3T MRI scanner

    PURPOSE: To correlate spin- spin relaxation time (T2) measurements with degree of hepatic fibrosis of ex vivo murine liver specimens at 3T MRI scanner. MATERIALS AND METHODS: The protocol and procedures were approved by The Institutional Animal Care and Use Committee (IACUC). Sixteen male, six week …

    bu Repository record for The effect of hepatic fibrosis on T2 value in a mouse model at 3T MRI scanner (opens in a new tab) Embargoed until 2999-01-01

  7. Entanglement with neutral atoms in the simulation of nonequilibrium dynamics of one-dimensional spin models

    … and role of entanglement in the dynamics of spin-1/2 models, both for the design of quantum gates for general-purpose quantum computation and for quantum simulation of interacting spin models. We introduce the neutral atom Mølmer-Sørensen gate, involving rapid adiabatic Rydberg dressing …

    unm Repository record for Entanglement with neutral atoms in the simulation of nonequilibrium dynamics of one-dimensional spin models (opens in a new tab)

  8. Dynamic Black Blood Carotid Artery Wall Imaging

    … a retrospectively gated black blood fast spin echo MR imaging technique to capture the motion of the carotid arterial wall over the cardiac cycle. The sequence was validated in digital phantoms and tested for functionality, accuracy and repeatability in volunteers. Distensibility measures …

    calgary Repository record for Dynamic Black Blood Carotid Artery Wall Imaging (opens in a new tab)

  9. Developing novel diffusion MRI methods for comprehensive analysis of restricted and anisotropic self-diffusion system

    … MRI methods, based on the pulsed gradient spin-echo sequence, employ magnetic field gradients to encode information about translational motion. However, this approach combines various aspects of diffusion, such as restriction, anisotropy, and flow, into a single observable, leading to …

    lund Repository record for Developing novel diffusion MRI methods for comprehensive analysis of restricted and anisotropic self-diffusion system (opens in a new tab) Download PDF for Developing novel diffusion MRI methods for comprehensive analysis of restricted and anisotropic self-diffusion system (opens in a new tab)

  10. Convolutional neural networks for head and neck tumor segmentation in MRI: protocol and sequence optimization

    … network of 6%.<br><br>Furthermore, a new sequence is developed to simultaneously measure T2 and ADC parameter maps.<br>The multiecho spin echo sequence with interleaved diffusion blocks is designed to eliminate geometric distortion artifacts present in conventional diffusion weighted MRI …

    freiburg-diss Repository record for Convolutional neural networks for head and neck tumor segmentation in MRI: protocol and sequence optimization (opens in a new tab)

  11. Understanding Water Diffusion in Experimental Spinal Cord Injury Remote from Injury Epicenter

    … (DTI) has demonstrated success as a biomarker of spinal cord injury (SCI) severity as shown from numerous preclinical studies. However, artifacts from stabilization hardware at the lesion have precluded its use for longitudinal assessments. Previous research has documented ex vivo diffusion …

    marquette Repository record for Understanding Water Diffusion in Experimental Spinal Cord Injury Remote from Injury Epicenter (opens in a new tab)

  12. Visualization and Localization of Interventional Devices with MRI by Susceptibility Mapping

    … L1 minimization algorithm. Specifically, the spin-echo sequence with a shifted 180-degree pulse is used to acquire high SNR data. A short shift time is used to avoid severe phase wrap. A phase unwrapping method based on Markov Random Field using Highest-Confidence-First algorithm is proposed …

    tamu Repository record for Visualization and Localization of Interventional Devices with MRI by Susceptibility Mapping (opens in a new tab)

  13. Diffusion tensor imaging at long diffusion time

    … tracking of smaller fibers. The Stimulated Echo Acquisition Mode (STEAM) sequence was modified to allow DTI measurements at long t[subscript diff] (approximately 200 ms), while avoiding T2 signal loss. For comparison, DTI data was acquired using STEAM at the shorter value of t[subscript …

    gatech Repository record for Diffusion tensor imaging at long diffusion time (opens in a new tab)

  14. Validation and optimization of myelin water imaging in a preclinical model of spinal cord injury

    … surrounding water. Typically, a lengthy multi-echo spin-echo sequence is used to obtain decay curves that are fitted to produce T2 distributions. In white matter, two peaks are observed, one with short and one with long T2 associated with water trapped between the myelin lipid bilayers and …

    ubc Repository record for Validation and optimization of myelin water imaging in a preclinical model of spinal cord injury (opens in a new tab) Download PDF for Validation and optimization of myelin water imaging in a preclinical model of spinal cord injury (opens in a new tab)

  15. An agile and stable optical system for high-fidelity coherent control of a single ??Sr? ion

    … using Rabi and Ramsey spectroscopy. Finally, a spin-echo sequence is used to enhance the storage time of the optical qubit, and high resolution scans over the quadrupole transition are performed to measure a system coherence time of 1 ms.

    strathclyde Repository record for An agile and stable optical system for high-fidelity coherent control of a single ??Sr? ion (opens in a new tab)

  16. Pathological and Biomedical Characteristics of Spinal Cord Injury Determined Using Diffusion Tensor Imaging

    Traumatic spinal cord injury: SCI) is the most devastating injury that often causes the victim permanent paralysis and undergo a lifetime of therapy and care. It is caused by a mechanical impact that ultimately causes pathophysiological consequences which at this moment in time are an unresolved …

    wustl Repository record for Pathological and Biomedical Characteristics of Spinal Cord Injury Determined Using Diffusion Tensor Imaging (opens in a new tab)

  17. Probing tissue microstructure using oscillating spin echo gradients

    … measurements rely on the pulsed gradient spin echo sequence which cannot provide short enough diffusion times to measure small axon diameters. Recent advances have allowed oscillating gradient (OG) diffusion MRI to infer the sizes of micron-scale axon diameters. Monte Carlo simulations of …

    manitoba Repository record for Probing tissue microstructure using oscillating spin echo gradients (opens in a new tab)

  18. Spin control and coherence in scalable phosphorus donor qubits

    … explore the use of localised electron or nuclear spin states of phosphorus atoms as quantum bits (qubits). Throughout this thesis we present four key developments in atomic-scale devices, focused on addressability and scalability. We extend the measurement capabilities in precision donor devices, …

    unsw Repository record for Spin control and coherence in scalable phosphorus donor qubits (opens in a new tab)

  19. Comparison of combinations of various levels of GraSE and compressed sensing on luminal water imaging measurements in MRI

    … decrease scanning times including gradient-and-spin echo (GraSE) imaging, and compressed sensing. One of the benefits of both techniques is that they can decrease scan time to varying degrees by changing the GraSE factor or sampling level. An electronic phantom was created to model a single …

    ubc Repository record for Comparison of combinations of various levels of GraSE and compressed sensing on luminal water imaging measurements in MRI (opens in a new tab) Download PDF for Comparison of combinations of various levels of GraSE and compressed sensing on luminal water imaging measurements in MRI (opens in a new tab)

Page 1 of 2