Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 13 of 13 for “"spin-echo method"”.

  1. Measurement of diffusion by the Spin-echo method

    A convenient and accurate method to measure the diffusion coefficient in a liquid is provided by nuclear magnetic resonance. It is called the "Spin-echo" method. Experimental apparatus has been built to observe spin-echos in samples of water. The results of these experiments agree with the theory …

    rice Repository record for Measurement of diffusion by the Spin-echo method (opens in a new tab)

  2. Magnetic resonance characterization of gadolinium-based contrast agents

    Several magnetic resonance methods have been used for characterizing gadolinium-based contrast agents in NMR Imaging in this thesis. Many Gd-based contrast agents were studied including Gd DTPA(dimethylenetriaminepentaacetic acid). The zero field splitting energies and g values of Gd complexes were …

    uiuc Repository record for Magnetic resonance characterization of gadolinium-based contrast agents (opens in a new tab)

  3. Spin echoes and chemical exchange

    The performance of a spin echo spectrometer which is suitable for chemical exchange studies is described. Using the Carr-Purcell sequence of pulses, proton T₂ values were obtained from two experiments differing only in their method of eliminating accumulated error in the width of the 180° pulses. …

    ubc Repository record for Spin echoes and chemical exchange (opens in a new tab) Download PDF for Spin echoes and chemical exchange (opens in a new tab)

  4. Study of chemical exchange kinetics by nuclear magnetic resonance

    … been made using the nuclear magnetic resonance spin echo method. A 40 Mc/sec. spin echo spectrometer, which enables measurements to be made of the transverse relaxation time (T₂) from a Carr Purcell sequence of radio-frequency pulses, is described and its performance illustrated. The precision …

    ubc Repository record for Study of chemical exchange kinetics by nuclear magnetic resonance (opens in a new tab) Download PDF for Study of chemical exchange kinetics by nuclear magnetic resonance (opens in a new tab)

  5. Three dimensional visualisation of TMJ anatomy using MRI techniques

    … technique of MRI imaging has been done with spin echo method for better tissue specificity.</p><p>The proposed work was done using computer graphics and image processing techniques to give better estimates of the volume of the TMJ by creating three dimensional reconstructions of the surface …

    njit Repository record for Three dimensional visualisation of TMJ anatomy using MRI techniques (opens in a new tab)

  6. Transport properties of micellar solutions and microemulsions.

    … Self-diffusion measurements were made by the NMR spin-echo method with a pulsed field gradient using the nucleus 1H. The results indicated that the surfactant is aggregated and water plus oxyethvlene chains form the continuum up to 100% surfactant. Phase diagrams were determined for the …

    sheffield-hallam Download PDF for Transport properties of micellar solutions and microemulsions. (opens in a new tab)

  7. Quantitative NMR imaging and its applications in vivo

    … use in vivo, have been investigated. The spin-lattice relaxation times (T₁) of water doped with various concentrations of paramagnetic species were determined using the inversion-recovery method. Intensity was measured directly from images as a function of tau and T₁ obtained from a three …

    ubc Repository record for Quantitative NMR imaging and its applications in vivo (opens in a new tab) Download PDF for Quantitative NMR imaging and its applications in vivo (opens in a new tab)

  8. Anisotropy of the self-diffusion coefficient of water in skeletal muscle

    … in skeletal muscle has been studied using the spin-echo method of pulsed NMR. The effective spin diffusion coefficient D as well as the relaxation times T1 and T2 of water in a variety of biological samples are reduced relative to their values in pure bulk water. Two explanations for these data …

    rice Repository record for Anisotropy of the self-diffusion coefficient of water in skeletal muscle (opens in a new tab)

  9. An interplay of feedforward and feedback signals supporting visual cognition

    … benchmarked three MR-sequences at 7T - gradient-echo, spin-echo, and vascular space occupancy - in their ability to differentiate feedforward and feedback signals in V1. The experiment in Study II consisted of two complementary tasks: a perception task that predominantly evokes feedforward …

    fu-berlin Repository record for An interplay of feedforward and feedback signals supporting visual cognition (opens in a new tab)

  10. Měření tkáňových kultur metodami magneticko resonanční tomografie

    … v jednotlivých řezech. Je zde popsána metoda spin-echo, která byla použita při měření. V této práci je uveden popis způsobu pořízení, výpočtu, vyhodnocení a grafické znázornění naměřených hodnot.

    brno-tech Repository record for Měření tkáňových kultur metodami magneticko resonanční tomografie (opens in a new tab)

  11. Magneticko-resonanční zobrazování tkáňových kultur

    … rezonancia, konkrétne zobrazovacia sekvencia spinálneho echa. Metoda spinového echa je založena na dvoch po sebe idúcich impulzoch 90° a 180°. Vybraná metoda z teoretickej časti práce je následne použitá k zmeraniu a spracovaniu tkáňových kultur. Záver práce je venovaný zpracovaniu dat v …

    brno-tech Repository record for Magneticko-resonanční zobrazování tkáňových kultur (opens in a new tab)

  12. Posouzení homogenity magnetického pole v tomografu

    … Je zde uveden základní fyzikální popis chování spinu v magnetickém poli. Dále jsou popsány metody pro měření NMR. Práce je zaměřena na metody spinového a gradientního echa. V experimentální části je popsáno měření homogenity magnetického pole v tomografu a následné zobrazení mapy měřeného pole. …

    brno-tech Repository record for Posouzení homogenity magnetického pole v tomografu (opens in a new tab)

  13. Způsoby váhovaní primárního parametru signálu magnetické rezonance

    Cílem této práce je seznámení se základním principem magnetické rezonance a základními měřicími metodami používanými v MR. Dále je zde popsáno, jak nastavovat parametry pulsní sekvence jednotlivých měřících metod, abychom získali obraz váhovaný relaxací T1, relaxací T2, difúzí a případně protonovou …

    brno-tech Repository record for Způsoby váhovaní primárního parametru signálu magnetické rezonance (opens in a new tab)