Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 22 for “"spinal segment"”.
-
Design and Validation of a Complex Loading Whole Spinal Segment Bioreactor
… this study was to develop and validate a whole spinal segment culturing system that loads the disc in complex loading similar to the in-vivo condition, while preserving the adjacent endplates and vertebral bodies. The complex loading applied to the spinal segment was achieved with three …
-
The role of inter-enlargement propriospinal neurons in locomotion following spinal cord injury.
… anatomically-defined pathways in the adult rat spinal cord before and after spinal cord injury (SCI). To do this, a TetOn dual virus system was used to selectively and reversibly silence neurons with cell bodies at spinal segment L2 and projections to spinal segment C6 (long ascending …
-
Experimental evaluation of spinal fracture stabilization systems : comparison of Luque rectangles, the Kaneda device, and Harrington rods with sublaminar wires
"At the University of Missouri-Columbia a spinal stabilization instrument evaluation system was developed by Carson, Gaines, Glascock, Karra, and Pak [3,16] to determine the ability of internal fixation devices to stabilize fractured spines. The system was designed to measure and calculate the …
-
The development of a posterior dynamic stabilisation implant indicated for thoraco-lumbar disc degeneration
Posterior lumbar spinal dynamic stabilisation devices are intended to relieve the pain of spinal segments while prolonging the lifespan of adjacent intervertebral discs. This study focuses on the design of such a device, one that has the correct stiffness to stabilise the spinal segment by the …
-
NONINVASIVE EVALUATIONS OF SLENDER GRAPHITE RODS AND HUMAN THORACOLUMBAR SPINE
… CT images: an isolated L1 vertebra and a T12-L2 spinal segment with ligaments, discs and facets. Each model was examined with both homogeneous and spatially varying bone tissue properties. Stresses and strains were compared for uniform compression and flexion. Inclusion of heterogeneous bone …
-
The Effects of Central Sensitization on Motoneurone Excitability in Osteoarthritis
… that increasing central sensitization within a spinal segment will cause a greater increase in the excitability of motoneurones in subjects with osteoarthritis when compared to healthy controls. To test this hypothesis, we experimentally induced central sensitization in individuals and monitored …
-
The Reliability of the Thoracic Percussion Test
… were instructed to tap along each subject’s paraspinal musculature and asked to indicate the most significant level of the thoracic spine that they felt would require treatment first. The therapists and subjects were randomized once again and the therapists were asked to repeat the same protocol. …
-
In vitro comparison of a new stand-alone anterior lumbar interbody cage device with established fixation techniques
… on the lumbar spine to relieve the pain. Spinal arthrodesis, i.e. joint fusion, is beneficial in many cases as the final option for patients suffering from certain types of low back pain (LBP). In order to promote solid fusion across a decompressed spinal segment, interbody spacers/cages …
-
Spinal Implant with Customized and Non-Linear Stiffness
There is a need for spinal implants that have nonlinear stiffness to provide stabilization if the spine loses stiffness through injury, degeneration, or surgery. There is also a need for spinal implants to be customizable for individual needs, and to be small enough to be unobtrusive once …
-
The role of ionotropic glutamate receptors in chronic central pain after spinal cord injury
Spinal cord injury (SCI) results in both loss of function and chronic central pain syndromes. In the clinical population, pain is characterized based on anatomical location: 1) Below-level pain – located at dermatomes corresponding to spinal segments caudal to the injury site, 2) At-level pain – …
-
Unraveling the mechanism of transcutaneous spinal cord stimulation in mitigating autonomic dysreflexia in experimental spinal cord injury
… condition that occurs after cervical or thoracic spinal cord injury (SCI) due to uncontrolled sympathetic reflexes. Sympathetic preganglionic neurons (SPNs), primarily localized within the intermediolateral cell column (IML) undergo maladaptive plasticity post-SCI and are strongly activated by …
-
BIOLIF: Biologic Lumbar Interbody Fusion - an instrumentation-free approach
Spinal fusion (SF) is a surgical procedure conducted to promote bone growth in-between spinal segments, supported by fixation hardware, and complemented by bone graft or bone substitute. There are recognized risks and complications associated with instrumentation, such as damage to surrounding …
-
Musculoskeletal Biomechanical and Electromyographical Responses Associated with Spinal Manipulation
… associated with cervical and upper thoracic spinal manipulation (SM). The overarching hypotheses were that: i) greater three-dimensional (3D) movements of the head and neck would be associated with larger vertebral artery (VA) strains; and ii) SM applied with greater force and more quickly …
-
Short and Long Term Immobilization on the Lumbar Spinal Joints: An Experimental Study Using Large Animal Model
… set up and validated. A reliable method of the spinal kinematic analysis was established. The second experimental portion evaluated the biomechanical aspect of a synthetic biomimetic spine model with a validated spinal biomechanical test system combined with the motion capture system set up in …
-
Medicinos personalo apatinės nugaros dalies biomechanines apkrovas veikiančių faktorių atliekant pacientų perkėlimą analizė. Analitinis klinikinis tvrimas /
… the biomechanical loads on the lumbar spine segment of the subjects at different moments of patient transfer; 3. To identify factors associated with subjects' physical and functional indicators and physical fitness that may influence the load on the L5-S1 spinal segment during patient …
-
Validation Testing of a Synthetic Spine and Upgraded Protocol for a Biomechanical Evaluation of a Lumbar Spinal Orthosis
… may work for some, but others go on to have spinal injections, opioids, or surgical procedures to alleviate pain. The Distractive and Mobility-Enabling Orthosis (DMO) was developed to meet the need for a conservative, drug-free treatment method. In this research, the low back support test …
-
Investigating molecular mechanisms of neuronal regeneration: a microarray approach.
… to the peripheral branch at the level of the spinal nerve (SN) results in axonal regeneration and reinnervation. Crush injury of the central branch in the dorsal root (DR) results in active regeneration up to the point of CNS entry at the DR entry zone (DREZ) and subsequent arrest of further …
-
Κινητικός έλεγχος των σταθεροποιών μυών του κορμού και σπονδυλικά κατάγματα σε γυναίκες με οστεοπόρωση: κλινική μελέτη
… are found to be unstable. Instability of the spinal segment can lead to excessive multiple tissue strain and consequent pain, while specific muscle contraction can stabilise that segment. Deep ‘local’ muscle with segmental attachments control the segmental movements of the spine and the …
-
TARGETING MALADAPTIVE PLASTICITY AFTER SPINAL CORD INJURY TO PREVENT THE DEVELOPMENT OF AUTONOMIC DYSREFLEXIA
… functions are susceptible to dysfunction after spinal cord injury (SCI), with cardiovascular dysregulation contributing to morbidity and mortality in the SCI population. Autonomic dysreflexia (AD) is a condition that develops after injury to the sixth thoracic spinal segment or higher and is …
-
The Development and Application of a Custom Robotic Biomechanical Testing Platform Employing Real-time Load-control to Compare Spinal Biomechanical Testing Protocols: Pure Moment, Ideal Follower Load, and a Novel Trunk Weight Protocol
… devices intended to relieve patient discomfort. Spinal biomechanics is a broad field containing but not limited to the in vitro study of cadaveric tissue utilizing testing platforms used to apply motion- or load-profiles to tissue in the investigation of the various kinetic or kinematic …
Page 1 of 2