Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 61 for “"spirometer"”.
-
Ultrasonic Continuous Wave Spirometer
There exists a problem of accurately performing spirographic measurements under physical stress situations. Existing systems, which use mechanical structures in the measurement process, have response times that are too slow, or are too bulky to be considered portable.The proposed system solves …
-
Design of a Low-Cost Spirometer to Detect COPD and Asthma for Remote Health Monitoring
… develops a simple and low-cost microphone-based spirometer with a scalable infrastructure that can be used to monitor COPD and Asthma symptoms. The data acquired from the system is archived in the cloud for further procuring and reporting. To develop this system, we utilize an off-the-shelf ESP32 …
-
Utveckling av en smart spirometer för mätning av lungfunktion - Vidareutveckling av mätinstrument med Arduino och sensorer
… som visar principen bakom en enkel digital spirometer, men inte ett färdigkalibrerat eller medicinskt verifierat mätsystem.
-
The respiratory rate and volume of the guinea pig
… selects an arrester on either the air supply spirometer or the air receiver spirometer. When the animal breathes in the air supply spirometer is free to move and the air receiver is locked allowing air to be taken from the air supply spirometer only. On expiration the reverse situation is in …
-
Έλεγχος της εγκυρότητας της διάγνωσης της χρόνιας αποφρακτικής πνευμονοπάθειας από ιατρούς της πρωτοβάθμιας φροντίδας
… underwent spirometry with the hand-held Piko-6 spirometer. Patients with known COPD, asthma or under treatment with bronchodilators were excluded. The results were compared with official spirometry parameters (Vitalograph dry spirometer) after bronchodilation. In addition the CAT questionnaire …
-
Correlation between tidal volume measured by spirometry and impedance pneumography
… volume was measured both by using a conventional spirometer and an impedance pneumograph, and evaluated quantitatively in 17 subjects using linear and nonlinear regression algorithms. Data were collected from 17 normal, healthy subjects during rest and paced breathing conditions. A technique was …
-
Remote Depth-based Photoplethysmography in Pulmonary Function Testing
… depth-based PFT measures and the measures from a spirometer.<br/><br/>Trunk motion during PFT affects the accuracy of these results, so the natural reaction of the subject's body to maximal inhalation and exhalation, must be decoupled from the chest-surface breathing motion. We present an …
-
Ánálise da capacidade funcional e da distribuição regional da ventilação pulmonar em pacientes com doença de chagas
… Minnesota questionnaire, six minute walk test, spirometer and manovacuometer was used. RESULTS: It was observed in the 6MWT where group CRL presented greater distance 464,93±44,63m versus Group HF with 399,58± 32,1m (p=0,005) and group CCC 404±68,24m (p=0,015), both the groups presented …
-
Kernel methods for biosensing applications
… motion artifact and highnoise conditions. A spirometer signal is used as the gold standard for evaluation oferrors. A novel algorithm called the segregated envelope and carrier (SEC) estimation is proposed. This algorithm approximates the spirometer signal by an amplitudemodulated signal and …
-
Sensor systems for automatic control of abdominal stimulation for respiratory support in tetraplegia
… mouth and nose, using a face mask connected to a spirometer. While this approach is suitable in a laboratory environment, the face mask is inconvenient for long-term, every day use. An alternative way to detect respiratory activity is to measure the movement of the abdomen, which is less intrusive …
-
The Effects of Various Respiratory Maneuvers on Transthoracic Impedance Measurements in Man
… in the thoracic gas volume measured with a spirometer during normal breathing. Most studies dealing with the comparison between transthoracic impedance changes and breathing have been concerned with modifying and improving the sensing devices and altering the size, shape, position, means of …
-
Abdominal stimulation for ventilation in tetraplegia
… was recorded from ten healthy volunteers using a spirometer (the current standard), a nasal thermocouple, and piezoelectric belts wrapped around the chest and abdomen. An algorithm was written for each of the sensors so that they could be used to trigger stimulation during quiet breathing. The …
-
Αναπνοομετρία παιδιών και εφήβων στη χώρα μας
… values were measured with electronicportable Spirometer Spirolab II (MIR) in 414 healthy, nonsmoking Greekchildren, aged 6-18 years. Linear regression analysis was performed for eachspirometric parameter against age, height, weight and body mass index(BMI).Results: The highest correlation was …
-
The effect of continuous and interval warm-up on post-exercise bronchoconstriction
… , FVC, and MMEFR were measured via the Breon spirometer prior to warm-up (CW and IW), ET, and every 2 minutes during a 25 minute passive recovery period. Post-exercise bronchoconstriction was taken as the largest decrease in %FEV₁⋅₀, %FVC, and %MMEFR during the recovery period. Significant …
-
A Case Study on Inference of Respiration from Torso-Mounted Inertial Measurement Units under Supine Breathing Conditions
… using seven torso-mounted IMUs and a reference spirometer across eight hour-long sessions of spontaneous supine breathing. A family of direction estimators based on generalized eigenvalue problems is evaluated under varying operating conditions. The influences of effective window length and …
-
Design, development, and characterization of breathforce : a respiratory training system for patients with spinal cord injuries.
… pressure (MIP) of the user and 2) function as a spirometer to track and display user data during respiratory muscle training (RMT). A transducer tester was used to apply a calibrated pressure to the device to validate the measurement accuracy. Measured values differed from the tester by …
-
Differences in Body Density and Perceived Exertion Determined by Hydrostatic Weighing at Three Selected Lung Volumes
… method of oxygen dilution. VC was measured by spirometer with the subject submerged to the neck in water. PITV was measured with the subject completely submerged at the time of weighing. DB was 1.045 ± .010, 1 . 050 ± .010, and 1.046 ± .010 for HW at RV, TLC, and PITV, respectively. RPE values …
-
Historic medical perspectives of corseting and two physiologic studies with reenactors
… of 9% of their tidal volume as measured by spirometer, with the range from 2%--29%. Shortness of breath was reported in varying degrees by all subjects, but was relieved easily with rest. No serious physiologic effects were seen with one day of corseting. Comfort was greater when …
-
Análise do drive respiratório neural em indivíduos hipertensos durante a ventilação máxima
… (ISAK), the VVM collected through the spirometer and the neural respiratory drive index (iDRN), collected through surface electromyography of the second intercostal space (EMGpara). Correlations were assessed by Pearson and Spearman tests, and for the NRD comparison, paired t-test was …
-
Accelerated Radial Magnetic Resonance Imaging: New Applications and Methods
… compared to those from simultaneously acquired spirometer measurements. Additionally, accelerated imaging methods can be used to improve upon widely used applications; we also present a technique for improved T₂-mapping. A novel model-based compressed sensing method is extended to include a …
Page 1 of 4