Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 10 of 10 for “"spliced reinforcement"”.

  1. Seismic retrofit of concrete columns with splice deficiencies by external prestressing.

    … concrete, and may improve the behaviour of spliced reinforcement under reversed cyclic loading. Six large scale bridge columns were built and tested under simulated seismic loading. Four long columns with a circular or a square cross-section of approximately 500 mm, and two short circular …

    ottawa-retro Repository record for Seismic retrofit of concrete columns with splice deficiencies by external prestressing. (opens in a new tab)

  2. A unified bond theory, probabilistic meso-scale modeling, and experimental validation of deformed steel rebar in normal strength concrete

    … validated with testing of concrete beams with spliced reinforcement, achieving a load capacity prediction error of less than 26%. The optimal rebar parameters and concrete cover in structural designs can be derived from this study."--Abstract, page iii.

    must-thes Repository record for A unified bond theory, probabilistic meso-scale modeling, and experimental validation of deformed steel rebar in normal strength concrete (opens in a new tab)

  3. Long-Term Performance of Seismically Rehabilitated Corrosion -Damaged Columns

    … reinforced concrete columns with lap-spliced reinforcement and subjected to lateral loading needs to be addressed. In order to simulate environmental conditions, circular reinforced concrete columns (500 mm in diameter and 3000 mm in height) were deteriorated by inducing accelerated …

    uiuc Repository record for Long-Term Performance of Seismically Rehabilitated Corrosion -Damaged Columns (opens in a new tab)

  4. Numerical investigation of bond deterioration in ASR-affected reinforced concrete beams with lap splices

    … in ASR-affected reinforced concrete beams with spliced bars. First, existing bond- slip models are examined, highlighting their range of applications and limitations when applied to deteriorated concrete. In addition, a comprehensive review of experimental studies is presented, establishing a …

    texas Repository record for Numerical investigation of bond deterioration in ASR-affected reinforced concrete beams with lap splices (opens in a new tab)

  5. Evaluation of required splice lengths for reinforcing bars in masonry wall construction

    … equation for the tensile resistance of spliced reinforcement was developed from the results of the wall splice specimen testing. This predictive equation was then adjusted to incorporate an adequate margin of safety for calculating splice length requirements for design purposes, using a …

    sask Repository record for Evaluation of required splice lengths for reinforcing bars in masonry wall construction (opens in a new tab)

  6. Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction

    … only develop 71% of the tensile resistance of spliced bars which are in contact. An experimental program was therefore initiated to design and evaluate remedial measures which can potentially increase the tensile resistance of non-contact lap splices to that of contact lap splice of the same …

    sask Repository record for Evaluation of Mitigative Techniques for Non-Contact Lap Splices in Concrete Block Construction (opens in a new tab)

  7. The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens

    The tensile resistance of No. 15 lap spliced reinforcing bars with varying transverse spacing and lap splice length was evaluated in full-scale concrete block wall splice specimens. The range of the transverse spacing between bars was limited to that which allowed the bars to remain within the same …

    sask Repository record for The Effect of Splice Length and Distance between Lapped Reinforcing Bars in Concrete Block Specimens (opens in a new tab)

  8. Θεραπεία ανεπάρκειας μήκους παράθεσης του διαμήκους οπλισμού υποστηλωμάτων παλαιών κατασκευών οπλισμένου σκυροδέματος

    … structures is the premature failure of the lap-spliced column longitudinal reinforcement. This brittle failure significantly affects the hysteretic response of the columns, which are structural members of the vertical bearing system, resulting in rapid degradation of lateral strength, ductility, …

    greece Repository record for Θεραπεία ανεπάρκειας μήκους παράθεσης του διαμήκους οπλισμού υποστηλωμάτων παλαιών κατασκευών οπλισμένου σκυροδέματος (opens in a new tab)

  9. Hooked Bar Anchorages and their Use in Noncontact Lap Splices

    … hooked bar lap splices without secondary reinforcement (e.g., ties) can fail due to a mode termed "hook side bulging", resulting from eccentricity between the lapped bars. Splices with secondary reinforcement typically fail due to more typical modes observed in the literature, such as …

    vt Repository record for Hooked Bar Anchorages and their Use in Noncontact Lap Splices (opens in a new tab)

  10. Effect of Splice Length and Creep on the Structural Response of Reinforced Concrete Columns Subjected to Pure Compressive Loading

    On June 24, 2021, the Champlain Towers South (CTS) condominiums in Surfside, Florida partially collapsed. A forensic investigation was launched by the National Institute of Standards and Technology (NIST) to determine the technical cause of the collapse and to use this understanding to recommend …

    washington Repository record for Effect of Splice Length and Creep on the Structural Response of Reinforced Concrete Columns Subjected to Pure Compressive Loading (opens in a new tab)