Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 20 of 52 for “"standard reference materials"”.

  1. Nitrogen Determination in Biological Standard Reference Materials via the 14-N (n,0) 14-C reaction

    Made available in DSpace on 2017-07-06T18:42:31Z (GMT). No. of bitstreams: 3 Boyle_Brian_J_MS.pdf: 23411355 bytes, checksum: 160f5df9c8fad6e0de35a8632ea9d131 (MD5) Boyle_Brian_J_MS_ABS.pdf: 350979 bytes, checksum: c2fde5ab7aac965bf74744d2f5b0cfd3 (MD5) license.txt: 4813 bytes, checksum: …

    uiuc Repository record for Nitrogen Determination in Biological Standard Reference Materials via the 14-N (n,0) 14-C reaction (opens in a new tab)

  2. DETERMINATION OF MOLECULAR MARKERS OF VACCINIUM BERRY STANDARD REFERENCE MATERIALS THROUGH DIFFERENTIAL ANALYSIS WITH ULTRAHIGH RESOLUTION LC/MS

    … and cranberries. The National Institute of Standards and Technology (NIST) manufactures standard reference materials (SRM) that were used as the samples for the purpose of method development. The differential analysis produced more than 1000 statistically significant species between the two …

    mtu Repository record for DETERMINATION OF MOLECULAR MARKERS OF VACCINIUM BERRY STANDARD REFERENCE MATERIALS THROUGH DIFFERENTIAL ANALYSIS WITH ULTRAHIGH RESOLUTION LC/MS (opens in a new tab)

  3. Method optimization for detection of arsenolipids in standard reference materials and seafood using HPLC-ICP-MS and HPLC-ESI-MS, and bioavailability of ASFA362 through In Vivo st

    … biological matrices and the absence of certified standard reference materials (SRMs). This study addresses these challenges by developing a workflow for identifying arsenolipids in biological samples, and harmonizing extraction and data processing methods across studies. Arsenolipids were …

    ttu Repository record for Method optimization for detection of arsenolipids in standard reference materials and seafood using HPLC-ICP-MS and HPLC-ESI-MS, and bioavailability of ASFA362 through In Vivo st (opens in a new tab)

  4. ICP Analysis of Solids/Waste Slurries

    … in coal, coal ash, cements, and refractory materials. In this study aqueous slurries of 6 coals were prepared by milling with a stirred-ball slurry attritor mill and an air impact pulverizer. ICP analysis values obtained for the six coals by the two different grinding methods were compared. …

    wku-diss Repository record for ICP Analysis of Solids/Waste Slurries (opens in a new tab)

  5. Trace Elemental Analysis of Ashes in the Combustion of the Binder Enhanced d-RDF by Inductively Coupled Plasma Atomic Emission Spectroscopy

    … method has been tested on a variety of standard reference materials, with reproducible and accurate results. Fourteen trace elements, As, Ba, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, Tl, V, and Zn, from the dissolved ash samples were determined by inductively coupled plasma atomic emission …

    unt Repository record for Trace Elemental Analysis of Ashes in the Combustion of the Binder Enhanced d-RDF by Inductively Coupled Plasma Atomic Emission Spectroscopy (opens in a new tab)

  6. ANALYSIS OF NUTRACEUTICALS FOR TOXIC METALS: DEVELOPMENT AND VALIDATION OF SAMPLE PREPARATION METHOD

    … (ICP-AES) for toxic metal content. Botanical standard reference materials (SRMs) of Ephedra sinica stapf and Gingko biloba were analyzed for arsenic, cadmium, lead, and mercury to assess the validity of the developed sample preparation method.

    clemson Repository record for ANALYSIS OF NUTRACEUTICALS FOR TOXIC METALS: DEVELOPMENT AND VALIDATION OF SAMPLE PREPARATION METHOD (opens in a new tab)

  7. Comparison of an Advanced Mercury Analyzer with the Cold Vapor Atomic Absorption Technique for the Determination of Mercury in Coal

    For over 30 years the industry standard method for mercury analysis has been the cold vapor atomic absorption spectrometric technique (CVAAS). Recent developments in improving this technique have focused on procedures for concentrating mercury in the analyte or materials to improve detection. The …

    wku-diss Repository record for Comparison of an Advanced Mercury Analyzer with the Cold Vapor Atomic Absorption Technique for the Determination of Mercury in Coal (opens in a new tab)

  8. ANALYTICAL APPLICATIONS OF PARTICLE INDUCED X-RAY EMISSION (PIXE) SPECTROSCOPY

    … and homogenous deposition of samples and standards with a minimum of contamination have been investigated. The accuracy of the method has been evaluated using five standard reference materials obtained from the National Bureau of Standards. The elimination of bremsstrahlung associated with …

    arizona-thes Repository record for ANALYTICAL APPLICATIONS OF PARTICLE INDUCED X-RAY EMISSION (PIXE) SPECTROSCOPY (opens in a new tab)

  9. Continuous hydride generation in the presence of L- cysteine for the determination of arsenic, bismuth, antimony and tin in steels by inductively coupled plasma atomic emission spectrometry

    … gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained …

    brock Repository record for Continuous hydride generation in the presence of L- cysteine for the determination of arsenic, bismuth, antimony and tin in steels by inductively coupled plasma atomic emission spectrometry (opens in a new tab)

  10. Analysis of surrogate post-detonation urban debris (SPUD) gamma rays and self-attenuation

    … nuclear forensics, there is a dearth of Standard Reference Materials (SRMs) suitable for such measurements that are traceable back to a national standard. Accordingly, the nuclear forensics community has requested SRMs be produced that mimic the post-detonation fallout debris that …

    gatech Repository record for Analysis of surrogate post-detonation urban debris (SPUD) gamma rays and self-attenuation (opens in a new tab)

  11. Quantification and computational modelling of radiation doses while handling Neutron Activation Analysis samples

    … is used to computationally irradiate sample materials in several positions in the TRIGA reactor core using various NIST standard reference materials and typical NAA samples. In a second MCNP 6.2 model, two different computational phantoms are modeled: 1) whole-body phantom and 2) hand …

    texas Repository record for Quantification and computational modelling of radiation doses while handling Neutron Activation Analysis samples (opens in a new tab)

  12. Environmental chemical analysis method optimization and application to northwest Cuban marine sediment

    … method was validated based on available QA/QC standards using several environmental samples, both sediment and biota, and standard reference materials. This contaminant-focused method can be used as a forensic geochemistry tool to evaluate oil contamination and other contaminant histories in …

    usf Repository record for Environmental chemical analysis method optimization and application to northwest Cuban marine sediment (opens in a new tab)

  13. Simultaneous Determination of Multiple Actinide Elements in a Variety of Soils Utilizing a Standardized Sequential Extraction Protocol

    … This work aims to continue development of a standard sequential extraction protocol and expanding its capabilities to include the analysis of multiple actinide elements across a broad range of soil types. A five-step sequential extraction procedure was used to analyze extraction behaviors of …

    unlv Repository record for Simultaneous Determination of Multiple Actinide Elements in a Variety of Soils Utilizing a Standardized Sequential Extraction Protocol (opens in a new tab) Download PDF for Simultaneous Determination of Multiple Actinide Elements in a Variety of Soils Utilizing a Standardized Sequential Extraction Protocol (opens in a new tab)

  14. ANALYTICAL DEVELOPMENTS IN X-RAY EMISSION SPECTROMETRY.

    … were applied to the analysis of five NBS standard reference materials, and to the analysis of deep-sea ferromanganese nodules. A high resolution (2 eV) PIXE system has been developed to aid in the deconvolution of overlapping X-ray peaks encountered in conventional PIXE spectra. This …

    arizona-thes Repository record for ANALYTICAL DEVELOPMENTS IN X-RAY EMISSION SPECTROMETRY. (opens in a new tab)

  15. Monte Carlo neutronic simulations for a new approach to parametric INAA and Mo-99 production feasibility at MURR

    … rates for a set of mostly dilute single-element standards in ROW2. Predictions of the intrinsic reaction rates for many nuclides, including those with high epithermal sensitivity and non-1/v behavior, are within [plus-minus] 5% of the measured values. Using predicted ([nu], [upsilon]) …

    missouri Repository record for Monte Carlo neutronic simulations for a new approach to parametric INAA and Mo-99 production feasibility at MURR (opens in a new tab)

  16. ΜΕΛΕΤΗ ΠΡΟΣΔΙΟΡΙΣΜΟΥ ΕΝΩΣΕΩΝ ΥΔΡΑΡΓΥΡΟΥ ΜΕ ΤΗ ΦΑΣΜΑΤΟΜΕΤΡΙΑ ΑΤΟΜΙΚΗΣ ΑΠΟΡΡΟΦΗΣΗΣ ΨΥΧΡΟΥ ΑΤΜΟΥ ΚΑΙ ΒΕΛΤΙΣΤΟΠΟΙΗΣΗ ΜΕ ΠΑΡΑΓΟΝΤΙΚΟ ΣΧΕΔΙΑ...

    … SAMPLES OF ENVIRONMENTAL INTEREST AS WELL AS TO STANDARD REFERENCE MATERIALS OF COMPOSITE STRUCTURE. THE PERFORMANCE CHARACTERISTICS OF THE METHOD WERE VERY GOODAND ALLOWED ACCURATE DETERMINATION OF MERCURY IN CONCENTRATION LEVELS OF SOME NG/1.

    greece Repository record for ΜΕΛΕΤΗ ΠΡΟΣΔΙΟΡΙΣΜΟΥ ΕΝΩΣΕΩΝ ΥΔΡΑΡΓΥΡΟΥ ΜΕ ΤΗ ΦΑΣΜΑΤΟΜΕΤΡΙΑ ΑΤΟΜΙΚΗΣ ΑΠΟΡΡΟΦΗΣΗΣ ΨΥΧΡΟΥ ΑΤΜΟΥ ΚΑΙ ΒΕΛΤΙΣΤΟΠΟΙΗΣΗ ΜΕ ΠΑΡΑΓΟΝΤΙΚΟ ΣΧΕΔΙΑ... (opens in a new tab)

  17. Investigations into the determinations of hydride-forming elements

    … Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of …

    brock Repository record for Investigations into the determinations of hydride-forming elements (opens in a new tab)

  18. DEVELOPMENT OF A REFERENCE METHOD FOR THE ABSOLUTE MEASURING OF FLUORESCENCE IN BIOLOGICAL ANALYSIS

    … the single instrument, hence the use of suitable reference materials is necessary to define its calibration scale. To overcome this problem, it is necessary to define a reliable and universal measurement unit allowing to measure the absolute fluorescence intensity, whichever system is used, …

    poli-torino Repository record for DEVELOPMENT OF A REFERENCE METHOD FOR THE ABSOLUTE MEASURING OF FLUORESCENCE IN BIOLOGICAL ANALYSIS (opens in a new tab)

Page 1 of 3