Global ETD Search
Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.
Results
Showing 1 to 20 of 52 for “"standard reference materials"”.
-
Nitrogen Determination in Biological Standard Reference Materials via the 14-N (n,0) 14-C reaction
Made available in DSpace on 2017-07-06T18:42:31Z (GMT). No. of bitstreams: 3 Boyle_Brian_J_MS.pdf: 23411355 bytes, checksum: 160f5df9c8fad6e0de35a8632ea9d131 (MD5) Boyle_Brian_J_MS_ABS.pdf: 350979 bytes, checksum: c2fde5ab7aac965bf74744d2f5b0cfd3 (MD5) license.txt: 4813 bytes, checksum: …
-
DETERMINATION OF MOLECULAR MARKERS OF VACCINIUM BERRY STANDARD REFERENCE MATERIALS THROUGH DIFFERENTIAL ANALYSIS WITH ULTRAHIGH RESOLUTION LC/MS
… and cranberries. The National Institute of Standards and Technology (NIST) manufactures standard reference materials (SRM) that were used as the samples for the purpose of method development. The differential analysis produced more than 1000 statistically significant species between the two …
-
Method optimization for detection of arsenolipids in standard reference materials and seafood using HPLC-ICP-MS and HPLC-ESI-MS, and bioavailability of ASFA362 through In Vivo st
… biological matrices and the absence of certified standard reference materials (SRMs). This study addresses these challenges by developing a workflow for identifying arsenolipids in biological samples, and harmonizing extraction and data processing methods across studies. Arsenolipids were …
-
ICP Analysis of Solids/Waste Slurries
… in coal, coal ash, cements, and refractory materials. In this study aqueous slurries of 6 coals were prepared by milling with a stirred-ball slurry attritor mill and an air impact pulverizer. ICP analysis values obtained for the six coals by the two different grinding methods were compared. …
-
Trace Elemental Analysis of Ashes in the Combustion of the Binder Enhanced d-RDF by Inductively Coupled Plasma Atomic Emission Spectroscopy
… method has been tested on a variety of standard reference materials, with reproducible and accurate results. Fourteen trace elements, As, Ba, Be, Cd, Cr, Cu, Hg, Ni, Pb, Sb, Se, Tl, V, and Zn, from the dissolved ash samples were determined by inductively coupled plasma atomic emission …
-
ANALYSIS OF NUTRACEUTICALS FOR TOXIC METALS: DEVELOPMENT AND VALIDATION OF SAMPLE PREPARATION METHOD
… (ICP-AES) for toxic metal content. Botanical standard reference materials (SRMs) of Ephedra sinica stapf and Gingko biloba were analyzed for arsenic, cadmium, lead, and mercury to assess the validity of the developed sample preparation method.
-
Comparison of an Advanced Mercury Analyzer with the Cold Vapor Atomic Absorption Technique for the Determination of Mercury in Coal
For over 30 years the industry standard method for mercury analysis has been the cold vapor atomic absorption spectrometric technique (CVAAS). Recent developments in improving this technique have focused on procedures for concentrating mercury in the analyte or materials to improve detection. The …
-
ANALYTICAL APPLICATIONS OF PARTICLE INDUCED X-RAY EMISSION (PIXE) SPECTROSCOPY
… and homogenous deposition of samples and standards with a minimum of contamination have been investigated. The accuracy of the method has been evaluated using five standard reference materials obtained from the National Bureau of Standards. The elimination of bremsstrahlung associated with …
-
Continuous hydride generation in the presence of L- cysteine for the determination of arsenic, bismuth, antimony and tin in steels by inductively coupled plasma atomic emission spectrometry
… gave promise for the future, due to low relative standard deviation. A method was developed for the determination of arsenic, bismuth, antimony and tin in low-alloy steels. Four standard reference materials from NIST were dissolved in 10 mL aqua regia without heat. Good agreement was obtained …
-
Analysis of surrogate post-detonation urban debris (SPUD) gamma rays and self-attenuation
… nuclear forensics, there is a dearth of Standard Reference Materials (SRMs) suitable for such measurements that are traceable back to a national standard. Accordingly, the nuclear forensics community has requested SRMs be produced that mimic the post-detonation fallout debris that …
-
Quantification and computational modelling of radiation doses while handling Neutron Activation Analysis samples
… is used to computationally irradiate sample materials in several positions in the TRIGA reactor core using various NIST standard reference materials and typical NAA samples. In a second MCNP 6.2 model, two different computational phantoms are modeled: 1) whole-body phantom and 2) hand …
-
The development of a technique for the determination of disolved chromium(III) and total dissolved chromium in seawater by electron capture detection gas chromatography
… of the technique was assessed by the analysis of standard reference materials from the National Research Council of Canada. The Cr values obtained for the reference materials using this method were in good agreement with the certified values. The technique has a precision of 1.3% at 4.67 nM with …
-
Environmental chemical analysis method optimization and application to northwest Cuban marine sediment
… method was validated based on available QA/QC standards using several environmental samples, both sediment and biota, and standard reference materials. This contaminant-focused method can be used as a forensic geochemistry tool to evaluate oil contamination and other contaminant histories in …
-
Simultaneous Determination of Multiple Actinide Elements in a Variety of Soils Utilizing a Standardized Sequential Extraction Protocol
… This work aims to continue development of a standard sequential extraction protocol and expanding its capabilities to include the analysis of multiple actinide elements across a broad range of soil types. A five-step sequential extraction procedure was used to analyze extraction behaviors of …
-
ANALYTICAL DEVELOPMENTS IN X-RAY EMISSION SPECTROMETRY.
… were applied to the analysis of five NBS standard reference materials, and to the analysis of deep-sea ferromanganese nodules. A high resolution (2 eV) PIXE system has been developed to aid in the deconvolution of overlapping X-ray peaks encountered in conventional PIXE spectra. This …
-
Monte Carlo neutronic simulations for a new approach to parametric INAA and Mo-99 production feasibility at MURR
… rates for a set of mostly dilute single-element standards in ROW2. Predictions of the intrinsic reaction rates for many nuclides, including those with high epithermal sensitivity and non-1/v behavior, are within [plus-minus] 5% of the measured values. Using predicted ([nu], [upsilon]) …
-
ΜΕΛΕΤΗ ΠΡΟΣΔΙΟΡΙΣΜΟΥ ΕΝΩΣΕΩΝ ΥΔΡΑΡΓΥΡΟΥ ΜΕ ΤΗ ΦΑΣΜΑΤΟΜΕΤΡΙΑ ΑΤΟΜΙΚΗΣ ΑΠΟΡΡΟΦΗΣΗΣ ΨΥΧΡΟΥ ΑΤΜΟΥ ΚΑΙ ΒΕΛΤΙΣΤΟΠΟΙΗΣΗ ΜΕ ΠΑΡΑΓΟΝΤΙΚΟ ΣΧΕΔΙΑ...
… SAMPLES OF ENVIRONMENTAL INTEREST AS WELL AS TO STANDARD REFERENCE MATERIALS OF COMPOSITE STRUCTURE. THE PERFORMANCE CHARACTERISTICS OF THE METHOD WERE VERY GOODAND ALLOWED ACCURATE DETERMINATION OF MERCURY IN CONCENTRATION LEVELS OF SOME NG/1.
-
Investigations into the determinations of hydride-forming elements
… Ge, Sn, and As were examined by the analyses of standard reference materials. Interference effects from the sample matrix, for example, in transition metal-rich samples, copper, iron and steel, were eliminated by L-cystine (for As and Sn) and by LI cysteine (for Ge). The analysis of a number of …
-
DEVELOPMENT OF A REFERENCE METHOD FOR THE ABSOLUTE MEASURING OF FLUORESCENCE IN BIOLOGICAL ANALYSIS
… the single instrument, hence the use of suitable reference materials is necessary to define its calibration scale. To overcome this problem, it is necessary to define a reliable and universal measurement unit allowing to measure the absolute fluorescence intensity, whichever system is used, …
-
SAMPLE PREPARATION TECHNIQUES FOR THE IMPROVEMENT OF ANALYTICAL MEASUREMENTS: CAPILLARY-CHANNELED POLYMER FIBERS EMPLOYED IN PROTEIN SOLID PHASE EXTRACTION APPLICATIONS AND CHARACTERIZATION OF ACTIVE COMPONENTS IN BOTANICAL DIETARY SUPPLEMENTS
… (LC-PB/EIMS) is also described. Here, NIST Standard Reference Materials (SRMs) were extracted using 80% methanol without a hydrolysis step. Samples were then analyzed using a chromatographic separation and analytes quantified by an internal standard (IS) method using 7-hydroxy-4-chromone as …
Page 1 of 3