Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results

Showing 1 to 19 of 19 for “"static calibration"”.

  1. High-Speed, High-Precision Digital -Analog Converters Designed for Spectral Performance

    … switched output. Provision is also made for static calibration to correct for current-source mismatch and attain the correct static linearity; this is also required for attaining the desired dynamic linearity. In the first prototype chip designed, the static calibration was in the form of a …

    uiuc Repository record for High-Speed, High-Precision Digital -Analog Converters Designed for Spectral Performance (opens in a new tab)

  2. Evaluation of an electronic wind-tunnel balance

    … using diode function-generating circuitry. A static calibration was conducted to confirm the linearity of the circuits. Evaluation of the balance system under operating conditions pointed out other areas for future investigation. Aerodynamic support tares must be determined, an improved pitch …

    nps Repository record for Evaluation of an electronic wind-tunnel balance (opens in a new tab)

  3. Dynamic Force Measurement Capabilities for Hypersonic Wind Tunnel Testing

    … Oak, Maryland, is expected to provide accurate static and dynamic force and moment measurements on conventional test articles, providing simultaneous force, moment, heat transfer, and pressure measurements for maximal test productivity. A finite element model of the model-balance-sting assembly …

    maryland Repository record for Dynamic Force Measurement Capabilities for Hypersonic Wind Tunnel Testing (opens in a new tab)

  4. Comparison calibration of piezoresistive microphones for acoustic power measurements

    A calibration of two Endevco piezoresistive microphones was carried out under static and dynamics pressures. The dynamic pressure calibrations were done by comparison with a B&K condenser microphone. The calibration was carried out in a small closed volume in air and helium. In helium, the codes …

    nps Repository record for Comparison calibration of piezoresistive microphones for acoustic power measurements (opens in a new tab)

  5. Dynamic Bayesian Approaches to the Statistical Calibration Problem

    The problem of statistical calibration of a measuring instrument can be framed both in a statistical context as well as in an engineering context. In the first, the problem is dealt with by distinguishing between the "classical" approach and the "inverse" regression approach. Both of these models …

    vcu Repository record for Dynamic Bayesian Approaches to the Statistical Calibration Problem (opens in a new tab)

  6. A linguistic method for robot verification programming and control

    … for online camera registration to avoid static calibration and handle changing camera positions. To handle concurrent communication with embedded robot hardware, we develop a new real-time interprocess communication system which offers lower latency than Linux sockets. Finally, we …

    gatech Repository record for A linguistic method for robot verification programming and control (opens in a new tab)

  7. Research on the Static Response Mechanism of Event Cameras and Their Applications in Static Scenes

    … motion capture. However, their potential in static scenes remains largely unexplored and not well understood. This research aims to address this gap by delving into the principles and applications of event cameras in static themes. This work explains the phenomenon that event cameras respond …

    washington Repository record for Research on the Static Response Mechanism of Event Cameras and Their Applications in Static Scenes (opens in a new tab)

  8. Desenvolvimento de dinamômetro híbrido aplicado ao 4° eixo de um centro de usinagem

    … design, engineering analyses, instrumentation, static calibration and natural frequency evaluation were fundamental for manufacturing the device. In addition, the development of a wireless data transfer system have been developed. For this step, it was necessary to create a couple of printed …

    brazil-ufrn Repository record for Desenvolvimento de dinamômetro híbrido aplicado ao 4° eixo de um centro de usinagem (opens in a new tab)

  9. Effect of previous hamstring strain on Anterior Cruciate Ligament (ACL) forces

    … landing from a jump. Ultrasound data, along with static calibration from motion capture, were used to develop the subject specific model. The purpose of this study was to determine if people with a previous hamstring strain had increased ACL forces during common activities of daily living and …

    ecu Repository record for Effect of previous hamstring strain on Anterior Cruciate Ligament (ACL) forces (opens in a new tab)

  10. The effects of operating conditions on the hydrodynamic lubricant film thickness at the piston-ring / cylinder liner interface of a firing diesel engine

    … assembly and commissioning of a novel dynamic calibration apparatus. The new system can also be used for static calibration (AM system) of capacitance based distance measuring systems. It uses a manufacturer calibrated closed loop controlled piezo-actuator to present a target relative to the …

    cent-lancashire Download PDF for The effects of operating conditions on the hydrodynamic lubricant film thickness at the piston-ring / cylinder liner interface of a firing diesel engine (opens in a new tab)

  11. Dynamic loads on spur gear teeth.

    … of tooth load and shaft torque respectively. A static tooth load calibration on a strain indicator was made by means of a load arm, a cable and dead weights. The static calibration helped to set the indicator so that the reading shown on it during the dynamic load test could be converted to the …

    ubc Repository record for Dynamic loads on spur gear teeth. (opens in a new tab) Download PDF for Dynamic loads on spur gear teeth. (opens in a new tab)

  12. An inertial sensor-based Motion capture pipeline for movement analysis

    … The subjects were asked to perform the 20s static calibration and the sit-stand-sit-walk task in the experiment. The human motion intention prediction method gives out a novel solution to low-cost motion intention prediction based on pure IMU data by fusing both musculoskeletal modeling …

    birmingham Download PDF for An inertial sensor-based Motion capture pipeline for movement analysis (opens in a new tab)

  13. Multi camera extrinsic calibration

    … importance. This is typically calibrated in a static rig upon manufacturing a vehicle, but after driving for a while the orientation of sensors might change due to bumps and vibrations, thus requiring regular recalibration. This thesis presents an automated refinement method for the rotations …

    chalmers Repository record for Multi camera extrinsic calibration (opens in a new tab)

  14. Applicability of IMU in Clinical Research: Improving Upper Limbs Sensor-to-segment Calibration

    … to orientation estimation, sensor-to-segment calibration and mitigation of soft tissue artifacts prevent such innovative technology from widespread use among the general population. To fill this gap, this work investigated three common sensor-to-segment calibration techniques, namely N-pose …

    trento Repository record for Applicability of IMU in Clinical Research: Improving Upper Limbs Sensor-to-segment Calibration (opens in a new tab)

  15. Force measurement techniques in short duration hypersonic facilities

    … system.</p> <p>This thesis introduces the static free-flight technique, whereby the aerodynamic pitching moment is minimised by matching the location of centre of gravity to centre of pressure, reducing the static margin of the model. This technique limits the dynamic influence on the …

    oxford Repository record for Force measurement techniques in short duration hypersonic facilities (opens in a new tab)

  16. Aspects of lubrication in piston cylinder assemblies

    … voltage is interpreted as film thickness through calibration. Ring profile fitting is being used as the standard calibration method, but also a dynamic technique has been proposed whereby a groove of known depth on a piston ring specimen is used to provide in-situ dynamic calibration, …

    greece Repository record for Aspects of lubrication in piston cylinder assemblies (opens in a new tab)

  17. Strain Gauge Utilization for Aerial Vehicle Dynamic Load Measurement

    … Load distribution data was first verified via both static calibration and in-flight total canopy load measurements. Drop testing was then conducted to identify loading asymmetry during both inflation and terminal descent. Results demonstrated the use of the strain gauge-based load distribution …

    umkc Repository record for Strain Gauge Utilization for Aerial Vehicle Dynamic Load Measurement (opens in a new tab)

  18. Measurements of Characteristics of an Electron Beam Using a Piezoelectric Probe

    Made available in DSpace on 2017-07-06T18:49:03Z (GMT). No. of bitstreams: 2 Kirkbride_Jeffrey_L_MS.pdf: 19274648 bytes, checksum: 29898077489021a3071cc6558132a9e4 (MD5) license.txt: 4813 bytes, checksum: 715c4321821a960fa1a1e91d2ac7ebce (MD5) Previous issue date: 1979

    uiuc Repository record for Measurements of Characteristics of an Electron Beam Using a Piezoelectric Probe (opens in a new tab)

  19. Advances in Humidity Standards

    L'abstract è presente nell'allegato / the abstract is in the attachment

    poli-torino Repository record for Advances in Humidity Standards (opens in a new tab)