A Sensor Based Approach to Analyzing Motion in Medical Applications: AV Fistula Cannulation and Rett Syndrome
… accuracy, and precision of each sensor. A static phantom was defined as the two endpoints of each of the six fistulas within the palpation simulator and the accuracy of the Leap Motion was <0.9 cm. The 9 DOF motion sensor, EMG sensor, and heart rate sensor all pass their respective …
-
Respiratory Compensated Robot for Liver Cancer Treatment: Design, Fabrication, and Benchtop Characterization
… N before the needle slips between the grippers. Static phantom targeting experiments indicate a positional error of 1.14 ± 0.30 mm and orientational error of 0.99° ± 0.36°. Static ex-vivo porcine liver targeting experiments indicate a positional error of 1.22 ± 0.31 mm and orientational error of …
-
A Platform for Robot-Assisted Intracardiac Catheter Navigation
… validated through in-vitro experiments with a static phantom, and in-vivo experiments on three live swines. The feasibility of automatic navigation was also veri ed by navigating to three landmarks in the beating heart of swine subjects, and comparing their performance with that of an …
-
Respiratory-gated liver stereotactic radiotherapy in flattening filter free photon mode
… bases for gated radiotherapy in FFF mode, a phantom was used to simulate respiratory traces of 10 patients previously treated for hepatic disease. Following 4DCT imaging, four plans were created and delivered for each respiratory trace; one nongated and three with the following gating …
-
A phantom based evaluation on the effects of patient breathing motion on Stereotactic Body Radiotherapy treatment volumes
… The aim of the study was to design an upper body phantom to mimic the movement of the lesion inside the lungs during a breathing cycle. Phantom design included an assessment of the motion observed for lung lesions, identification of suitable phantom materials as well as design of a motorized arm …
-
Quantifying The Magnitude of to tal Dose Deviation Caused By Various Sources of Error Among Iroc Phantom Irradiation Results
The Imaging and Radiation Oncology Core (IROC) phantoms are used as an end-to-end test of an institution’s radiotherapy processes, and for clinical trial credentialing. Phantoms are treated like patients, and evaluation of the doses received by the thermoluminescent dosimeters (TLDs) inside the …
-
Návrh a konstrukce fantomů pro MR zobrazování
Práca sa zaoberá návrhom realizácie statického fantómu pre zobrazovanie prostredníctvom magnetickej rezonancie. Rieši vznik samotného obrazu získaného pomocou magnetickej rezonancie a fyzikálne princípy tejto techniky. Takisto sú v práci rozoberané jednotlivé druhy fantómov, a to dynamické a …
-
Akvizice a předzpracování MRI obrazových sekvencí pro klinické perfusní zobrazování
Tato diplomová práce popisuje teorii pro statické a dynamické magneto-rezonanční zobrazování s použitím kontrastní látky ovlivňující relaxační dobu T1. Jsou popsány dostupné akviziční metody v určeném nemocničním zařízení Masarykova onkologického ústavu v Brně. Jsou vybrány vhodné sekvence pro …