Global ETD Search

Search theses and dissertations gathered from participating repositories worldwide. Every result links back to the library that holds it. No account is needed.

Results 1 to 20 of 28 for “"static resistance"”

  1. Experimental static resistance of cold-formed steel roof truss systems

    … analysis is commonly used to project blast resistance of complicated structural systems. In order to perform the SDOF analysis, a static resistance function is required. This study aims to analyze the full static resistance of full-scale cold-formed steel trusses commonly used in the …

    missouri Repository record for Experimental static resistance of cold-formed steel roof truss systems (opens in a new tab)

  2. Experimental evaluation and modeling of concrete masonry unit walls

    … infill wall systems do not exhibit the blast resistance necessary. To develop blast design guidelines for Concrete Masonry Unit (CMU) wall systems, it is necessary to develop analytical models for the static resistance function of these walls that are verified using the results of full-scale …

    missouri Repository record for Experimental evaluation and modeling of concrete masonry unit walls (opens in a new tab)

  3. Sheet retrofit systems for concrete slabs for blast mitigation

    … it is first necessary to develop static resistance functions which are experimentally verified. Static resistance functions were developed for various types of sheet retrofits and a reinforced concrete slab using a mechanics of materials approach. The individual models for the …

    missouri Repository record for Sheet retrofit systems for concrete slabs for blast mitigation (opens in a new tab)

  4. Roof truss systems under blast loads

    … The uncertainty of blast loads and roof resistance can lead to either excessive costs or insufficient blast designs. Therefore, the research presented here aims to bridge the gap in the knowledge about the blast resistance of different roof systems; Open Web Steel Joist (OWSJ) systems and …

    missouri Repository record for Roof truss systems under blast loads (opens in a new tab)

  5. Blast retrofit design of CMU walls using polymer sheets

    … ascertain the strength, ductility, response to static pressure, investigate connection details, and develop an analytical model of the static resistance function. The polymer retrofit system is modeled dynamically in a single degree of freedom (SDOF) model. The analytical model developed for the …

    missouri Repository record for Blast retrofit design of CMU walls using polymer sheets (opens in a new tab)

  6. Análise geoestatística da estimativa de resistência estátistica a partir de ensaios SPT

    Prediction of the soil-structure static resistance is primordial in foundation engineering design projects. Use of methods for prediction of pile bearing capacity based on standard penetration test (SPT) results is a common practice. Simplicity and low costs make the SPT one of the most employed …

    brazil-ufrn Repository record for Análise geoestatística da estimativa de resistência estátistica a partir de ensaios SPT (opens in a new tab)

  7. Feasibility of Pile Driving Analyzer for Pile On Rock

    … used methods are high strain dynamic piles and static load testing. Static load testing is very time-consuming, requires heavy deadloads and much space, and doesn’t have stress monitoring advantages in piles. High strain dynamic has been employed as an alternative in this regard. Pile dynamic …

    gsu Repository record for Feasibility of Pile Driving Analyzer for Pile On Rock (opens in a new tab)

  8. BLAST DAMAGE MITIGATION IN SUBMERGED SYSTEMS. PHASE I: INTERNAL EXPLOSION

    … steel sandwich panels under both quasi-static loads and confined explosions, where a total of fifty-seven sandwich panels were tested, considering various core configurations, different core sheet thickness, and different blast load intensity levels. The American ASCE/SEI 59-11 and The …

    mcmaster Repository record for BLAST DAMAGE MITIGATION IN SUBMERGED SYSTEMS. PHASE I: INTERNAL EXPLOSION (opens in a new tab)

  9. Behavior and design of steel-plate composite (SC) walls for blast loads

    … validated bilinear strain hardening static resistance functions and exponential decay or triangular load pulse forcing functions. The idealized static resistance functions were developed from static tests of eight configurations of SC walls which were also used to benchmark the FE …

    purdue-thes Repository record for Behavior and design of steel-plate composite (SC) walls for blast loads (opens in a new tab)

  10. Blast response of structural envelope elements : LG windows and CFS roof trusses

    … limited understanding of the blast response and resistance of windows and roof truss systems. Therefore, in this dissertation, the blast response and resistance of these two critical structural envelope elements, namely laminated glass (LG) windows and CFS roof trusses, were evaluated numerically …

    missouri Repository record for Blast response of structural envelope elements : LG windows and CFS roof trusses (opens in a new tab)

  11. Analytical and experimental evaluation of steel sheets for blast retrofit design

    … the applied loads during a blast event. The static resistance of the wall system can be analytically predicted and experimentally verified. Additionally, an efficient means of connecting the steel sheets to the wall system can be experimentally determined. The analytical model will ultimately …

    missouri Repository record for Analytical and experimental evaluation of steel sheets for blast retrofit design (opens in a new tab)

  12. Analysis and design of reinforced concrete wall systems for blast

    … that enhances the energy efficiency and blast resistance of the building making it ideal for military and government facilities. Current design recommendations are very restrictive when using these forms of construction, due in large part to the lack of experimental research data. To develop …

    missouri Repository record for Analysis and design of reinforced concrete wall systems for blast (opens in a new tab)

  13. In-Process Weld Quality Monitoring Techniques for Resistance-Spot Welds

    Dynamic resistance and thermal condition of the weld are the two process parameters which are monitored and related to weld quality of resistance-spot welds in mild steel. The investigation reported in Part I is concerned with measurement and application of dynamic or instantaneous resistance of …

    aston Repository record for In-Process Weld Quality Monitoring Techniques for Resistance-Spot Welds (opens in a new tab)

  14. Experimental evaluation of structural composites for blast resistant design

    … the overhead protection roof panel experiment. Static resistance functions were developed using a combination of analytical and laboratory testing in order to obtain the panels response using a single-degree of freedom (SDOF) dynamic analysis. Engineering analytical models were able to predict …

    missouri Repository record for Experimental evaluation of structural composites for blast resistant design (opens in a new tab)

  15. Evaluation of conventional steel stud walls for blast design

    … for conventional steel stud walls. Twenty-seven static tests have been conducted utilizing full-scale samples and deflection-controlled load application. An analytical model for predicting the static resistance of these walls under uniform loading was developed and verified through the testing. …

    missouri Repository record for Evaluation of conventional steel stud walls for blast design (opens in a new tab)

  16. Evaluation of a mechanical anchoring system to improve performance of carbon fiber reinforced polymer mitigated concrete slabs under close in blasts

    … of the full CFRP strength during flexure. A static three-point-bending test is performed in order to evaluate the efficacy of the anchoring system and to determine a static resistance function. Finally, nonlinear bending analysis is used to validate the test results, and the static test …

    missouri Repository record for Evaluation of a mechanical anchoring system to improve performance of carbon fiber reinforced polymer mitigated concrete slabs under close in blasts (opens in a new tab)

  17. Rate effects of rapid loading in clay soils.

    … soils due to the non linear variation in shear resistance with rate of shearing. An investigation has been conducted for two clay soils which were used in an associated research project. These were a reconstituted kaolin clay (KSS) used for model pile tests and undisturbed glacial clay taken …

    whiterose Repository record for Rate effects of rapid loading in clay soils. (opens in a new tab)

  18. Degradação dos cintos de segurança contra quedas após uso por ramo de atividade

    … caracterization of textile materials, static and dynamic tests on said samples. The results confirm several types of degradation found in previous research and demonstrate that most of the defects found are related to corrosion of metallic elements (90 %), dirt (50 %) and wear on the …

    brazil-ufrn Repository record for Degradação dos cintos de segurança contra quedas após uso por ramo de atividade (opens in a new tab)

  19. A dynamic circuit-based model for ferromagnetic materials

    … for this material, a circuit model that has static parameters is unable to accurately reproduce the behaviour of the actual material over a large range of input frequencies and excitation levels without resorting to retuning the parameters of the model. This thesis provides two new mechanisms …

    ubc Repository record for A dynamic circuit-based model for ferromagnetic materials (opens in a new tab)

  20. Characterization of polymer-fiber composite sheet retrofits for blast mitigation

    … the connection details, and a preliminary static resistance function for the PFCS are evaluated experimentally in this thesis. The research has focused on evaluating the load-deflection response of the PFCS at the macro level using full scale tension tests. The connection response in …

    missouri Repository record for Characterization of polymer-fiber composite sheet retrofits for blast mitigation (opens in a new tab)

Page 1 of 2